Evaluating the Potential, Applicability, and Effectiveness of Ozone Sterilization Process for Medical Devices

被引:16
作者
Botelho-Almeida, Tulia de Souza [1 ]
Lourenco, Felipe Rebello [1 ]
Kikuchi, Irene Satiko [1 ]
Awasthi, Rajendra [2 ]
Dua, Kamal [3 ,4 ,5 ]
Andreoli Pinto, Terezinha de Jesus [1 ]
机构
[1] Univ Sao Paulo, Dept Pharm, Fac Pharmaceut Sci, Av Prof Lineu Prestes 580,Bloco 13, BR-05508000 Sao Paulo, Brazil
[2] NKBR Coll Pharm & Res Ctr, Meerut 245206, Uttar Pradesh, India
[3] Univ Technol Sydney, Grad Sch Hlth, Discipline Pharm, Sydney, NSW 2007, Australia
[4] Shoolini Univ, Sch Pharmaceut Sci, Solan 173229, Himachal Prades, India
[5] Univ Newcastle, Sch Biomed Sci & Pharm, Newcastle, NSW 2308, Australia
关键词
Low temperature; Medical devices; Ozone; Sterilization; HYDROGEN-PEROXIDE; STAPHYLOCOCCUS-AUREUS; GASEOUS OZONE; INACTIVATION; GAS; DECONTAMINATION; PLASMAS; SPORES;
D O I
10.1007/s12247-017-9308-7
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose Ozone (O-3) can be considered the most potent natural germicide against microorganisms (in vegetative and spore forms) with high efficiency and speed, because of its highly oxidizing activity. Despite this, there are a few studies describing the application of ozone as a sterilizing agent of medical devices. The aim of this communication was to describe the development and validation of a sterilization cycle applied to medical devices. Methods The sterilization process was challenged using Geobacillus stearothermophilus ATCC 7953 spores, which have shown great resistance. The sterilizing effect of ozone was measured using carriers inoculated with 10(6) CFU/mL spores, introduced into a 3-mL syringe and lumens of tubes of different sizes and diameters simulating hospital medical products, which have undergone a half-cycle or complete cycle. Results The results of sterilization process studied in active vegetative form of microorganisms showed that the ozone sterilization was effective with a bioburden between 10(5) to 10(7) CFU/mL with one pulse sterilizing action. The validation of the process was confirmed by the satisfactory results for the half-cycle, corresponding to a treatment with four pulses allowed sterilizing the material with bioburdens < 10(6) CFU/mL spores which indicate an appropriate sterility assurance level. Conclusion The results showed that the ozone may be considered as effective and promising alternative for sterilization of thermosensitive materials and medical devices.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 35 条
[1]  
[Anonymous], 2015, CONTROLE BIOL QUALID
[2]  
[Anonymous], 2005, OZONE NEW MED DRUG
[3]   Ozone and short-term mortality in 95 US urban communities, 1987-2000 [J].
Bell, ML ;
McDermott, A ;
Zeger, SL ;
Samet, JM ;
Dominici, F .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (19) :2372-2378
[4]  
Bocci V, 1993, MEDIATINFLAMM, V7, P313
[5]  
Boscariol MR, 2008, INT J PHARMACEUT, V353, P170, DOI [10.1016/j.ijphartn.2007.11.059, 10.1016/j.ijpharm.2007.11.059]
[6]  
Buranov SN, 2005, PULS POW C IEEE, DOI [10.1109/PPC.2005.300669, DOI 10.1109/PPC.2005.300669]
[7]   TAILING OF SURVIVAL CURVES OF BACTERIAL-SPORES [J].
CERF, O .
JOURNAL OF APPLIED BACTERIOLOGY, 1977, 42 (01) :1-19
[8]   Sterilization of biological pathogens using supercritical fluid carbon dioxide containing water and hydrogen peroxide [J].
Checinska, Aleksandra ;
Fruth, Ingrid A. ;
Green, Tonia L. ;
Crawford, Ronald L. ;
Paszczynski, Andrzej J. .
JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 87 (01) :70-75
[9]   In situ decontamination of medical wastes using oxidative agents: a 16-month study in a polyvalent intensive care unit [J].
Coronel, B ;
Duroselle, P ;
Behr, H ;
Moskovtchenko, JF ;
Freney, J .
JOURNAL OF HOSPITAL INFECTION, 2002, 50 (03) :207-212
[10]   Deactivation of clumped and dirty spores of Bacillus globigii [J].
Currier, RP ;
Torraco, DJ ;
Cross, JB ;
Wagner, GL ;
Gladden, PD ;
Vanderberg, LA .
OZONE-SCIENCE & ENGINEERING, 2001, 23 (04) :285-294