Modelling a 7-Level Asymmetrical H-Bridge Multilevel Inverter with PS-SPWM Control

被引:0
作者
Kabalci, Ersan [1 ]
Colak, Ilhami [2 ]
Bayindir, Ramazan [2 ]
Pavlitov, Constantin [3 ]
机构
[1] Univ Nevsehir, Dept Elect & Automat, Hacibektas, Nevsehir, Turkey
[2] Gazi Univ, Fac Technol, Dept Elect & Elect Engn, Ankara, Turkey
[3] Tech Univ Sofia, Fac Automat, Sofia, Bulgaria
来源
INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS & ELECTROMOTION JOINT CONFERENCE | 2011年
关键词
Multilevel Inverter; Phase Shifted Sinusoidal Pulse; Width Modulation (PS-SPWM); Harmonics Elimination;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Although the multilevel inverter topologics are comprehensively studied in power conversion issues, novel topologies are still being sought in order to decrease required semiconductors for same output levels that are currently obtained with classical multilevel topologies. Several studies have been reported in the literature on multilevel inverter topologies and control techniques. However, the cascaded multilevel inverter topology is one of the most widely studied topology to increase the output levels, asymmetrical topology in cascaded multilevel allow to increase output level with less switches. This paper presents a solution to improve efficiency of a cascaded multilevel inverter by converting it to an asymmetrical topology and proposing a control scheme to increase output voltage levels. The proposed 24-channel phase shifted sinusoidal pulse width modulation (PS-SPWM) circuit generates switching orders to be applied to the asymmetrical H-bridge cells. The designed voltage source inverter (VSI) is supplied with DC sources at V divided by 2V ratio to generate 7-level phase voltages at the output. The multilevel inverter is commutated at 2.5 kHz and 5 kHz switching frequencies and total harmonic distortion (THD) ratios are analysed. While the line voltage THD and line current THD ratios are measured as 42.98% and 1.29% respectively at 2.5 kHz switching frequency (f(sw)), they are decreased to 14.49% and 0.29% by increasing f(sw) to 5 kHz. Due to harmonics are appear as side-bands around f(sw) and its multiples in the PS-SPWM, the decrement on THD ratios can be obtained by increasing the f(sw) to an adequate limit without requiring any filter.
引用
收藏
页码:578 / 583
页数:6
相关论文
共 29 条
  • [1] [Anonymous], 2010, J METEOROL ENV
  • [2] Bose B.K., 2002, MODERN POWER ELECT A
  • [3] Brando G., 2010, 5 IET INT C POWER EL, P1
  • [4] Colak I., 2009, TUBAV SCI, V1, P45
  • [5] Colak I., 2010, 20 INT S POW EL EL D
  • [6] Colak I., EPE 2009, P1
  • [7] Review of multilevel voltage source inverter topologies and control schemes
    Colak, Ilhami
    Kabalci, Ersan
    Bayindir, Ramazan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (02) : 1114 - 1128
  • [8] Model Predictive Control of Multilevel Cascaded H-Bridge Inverters
    Cortes, Patricio
    Wilson, Alan
    Kouro, Samir
    Rodriguez, Jose
    Abu-Rub, Haitham
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) : 2691 - 2699
  • [9] Asymmetrical Multilevel Inverter for Traction Drives Using Only One DC Supply
    Dixon, Juan
    Pereda, Javier
    Castillo, Carlos
    Bosch, Sebastian
    [J]. IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2010, 59 (08) : 3736 - 3743
  • [10] Ebrahimi J, 2010, POW QUAL C PQC 2010, P1