Biomechanical Analysis of a New Carbon Fiber/Flax/Epoxy Bone Fracture Plate Shows Less Stress Shielding Compared to a Standard Clinical Metal Plate

被引:65
作者
Bagheri, Zahra S. [1 ]
Avval, Pouria Tavakkoli [1 ]
Bougherara, Habiba [1 ]
Aziz, Mina S. R. [2 ]
Schemitsch, Emil H. [2 ,3 ,4 ]
Zdero, Radovan [1 ,4 ]
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[2] Univ Toronto, Inst Med Sci, Toronto, ON M5S 1A8, Canada
[3] Univ Toronto, Fac Med, Toronto, ON M5S 1A8, Canada
[4] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2014年 / 136卷 / 09期
关键词
biomechanics; composite plate; metal plate; femur; flax/epoxy; fracture; PERIPROSTHETIC FEMORAL FRACTURE; TOTAL HIP IMPLANT; INFRARED THERMOGRAPHY; INTERNAL-FIXATION; BIOLOGICAL RESPONSE; SCREW PURCHASE; PLASTIC PLATES; HUMAN FEMURS; FIBER; TIP;
D O I
10.1115/1.4027669
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Femur fracture at the tip of a total hip replacement (THR), commonly known as Vancouver B1 fracture, is mainly treated using rigid metallic bone plates which may result in "stress shielding" leading to bone resorption and implant loosening. To minimize stress shielding, a new carbon fiber (CF)/Flax/Epoxy composite plate has been developed and biomechanically compared to a standard clinical metal plate. For fatigue tests, experiments were done using six artificial femurs cyclically loaded through the femoral head in axial compression for four stages: Stage 1 (intact), stage 2 (after THR insertion), stage 3 (after plate fixation of a simulated Vancouver B1 femoral midshaft fracture gap), and stage 4 (after fracture gap healing). For fracture fixation, one group was fitted with the new CF/Flax/Epoxy plate (n = 3), whereas another group was repaired with a standard clinical metal plate (Zimmer, Warsaw, IN) (n = 3). In addition to axial stiffness measurements, infrared thermography technique was used to capture the femur and plate surface stresses during the testing. Moreover, finite element analysis (FEA) was performed to evaluate the composite plate's axial stiffness and surface stress field. Experimental results showed that the CF/Flax/Epoxy plated femur had comparable axial stiffness (fractured = 645 +/- 67 N/mm; healed = 1731 +/- 109 N/mm) to the metal-plated femur (fractured = 658 +/- 69 N/mm; healed = 1751 +/- 39 N/mm) (p = 1.00). However, the bone beneath the CF/Flax/Epoxy plate was the only area that had a significantly higher average surface stress (fractured = 2.10 +/- 0.66 MPa; healed = 1.89 +/- 0.39 MPa) compared to bone beneath the metal plate (fractured = 1.18 +/- 0.93 MPa; healed = 0.71 +/- 0.24 MPa) (p<0.05). FEA bone surface stresses yielded peak of 13 MPa at distal epiphysis (stage 1), 16 MPa at distal epiphysis (stage 2), 85 MPa for composite and 129 MPa for metal-plated femurs at the vicinity of nearest screw just proximal to fracture (stage 3), 21 MPa for composite and 24 MPa for metal-plated femurs at the vicinity of screw farthest away distally from fracture (stage 4). These results confirm that the new CF/Flax/Epoxy material could be a potential candidate for bone fracture plate applications as it can simultaneously provide similar mechanical stiffness and lower stress shielding (i.e., higher bone stress) compared to a standard clinical metal bone plate.
引用
收藏
页数:10
相关论文
共 74 条
[51]   AOA-COA Symposium The Evidence-Based Approach in Bringing New Orthopaedic Devices to Market [J].
Schemitsch, Emil H. ;
Bhandari, Mohit ;
Boden, Scott D. ;
Bourne, Robert B. ;
Bozic, Kevin J. ;
Jacobs, Joshua J. ;
Zdero, Rad .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (04) :1030-1037
[52]   The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both? [J].
Shah, S. ;
Kim, S. Y. R. ;
Dubov, A. ;
Schemitsch, E. H. ;
Bougherara, H. ;
Zdero, R. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H9) :845-856
[53]   Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages [J].
Shah, Suraj ;
Bougherara, Habiba ;
Schemitsch, Emil H. ;
Zdero, Rad .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (10) :1496-1502
[54]   Biomechanical analysis using infrared thermography of a traditional metal plate versus a carbon fibre/epoxy plate for Vancouver B1 femur fractures [J].
Siddiqui, Faisal S. ;
Shah, Suraj ;
Nicayenzi, Bruce ;
Schemitsch, Emil H. ;
Zdero, Radovan ;
Bougherara, Habiba .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (01) :107-113
[55]  
SKINNER HB, 1988, CLIN ORTHOP RELAT R, P224
[56]  
SKIRVING AP, 1987, CLIN ORTHOP RELAT R, P117
[57]  
Strycker M L, 1995, J Foot Ankle Surg, V34, P82
[58]   Fixation of long bone segmental defects: A biomechanical study [J].
Talbot, Max ;
Zdero, Rad ;
Garneau, Daniel ;
Cole, Peter A. ;
Schemitsch, Emil H. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (02) :181-186
[59]   HOW STIFF SHOULD SEMI-RIGID FIXATION OF THE HUMAN TIBIA BE - A CLUE TO THE ANSWER [J].
TAYTON, K ;
BRADLEY, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (03) :312-315
[60]   THE USE OF SEMIRIGID CARBON-FIBER-REINFORCED PLASTIC PLATES FOR FIXATION OF HUMAN FRACTURES - RESULTS OF PRELIMINARY TRIALS [J].
TAYTON, K ;
JOHNSONNURSE, C ;
MCKIBBIN, B ;
BRADLEY, J ;
HASTINGS, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (01) :105-111