A Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the Advanced Clinical Solutions Word Choice Test as a Performance Validity Test

被引:37
作者
Bernstein, Matthew T. [1 ]
Resch, Zachary J. [1 ,2 ]
Ovsiew, Gabriel P. [1 ]
Soble, Jason R. [1 ,3 ]
机构
[1] Univ Illinois, Coll Med, Dept Psychiat, Chicago, IL 60607 USA
[2] Rosalind Franklin Univ Med & Sci, Dept Psychol, N Chicago, IL 60064 USA
[3] Univ Illinois, Coll Med, Dept Neurol, Chicago, IL USA
关键词
Word choice test; WCT; Performance validity; Diagnostic accuracy; Systematic review; Meta-analysis; RECOGNITION MEMORY TEST; CLASSIFICATION ACCURACY; INADEQUATE EFFORT; HETEROGENEITY; INDEXES; TRIAL;
D O I
10.1007/s11065-020-09468-y
中图分类号
B849 [应用心理学];
学科分类号
040203 ;
摘要
Thorough assessment of performance validity has become an established standard of practice in neuropsychological assessment. While there has been a large focus on the development and cross-validation of embedded performance validity tests (PVTs) in recent years, new freestanding PVTs have also been developed, including the Word Choice Test (WCT) as part of the Advanced Clinical Solutions Effort System. And, while the WCT's general utility for identifying invalid performance has been demonstrated in the ensuing decade since its initial publication, optimal cut-scores and associated psychometric properties have varied widely across studies. This study sought to synthesize the existing diagnostic accuracy literature regarding the WCT via a systematic review and to conduct a meta-analysis to determine the performance validity cut-score that best maximizes sensitivity while maintaining acceptable specificity. A systematic search of the literature resulted in 14 studies for synthesis, with eight of those available for meta-analysis. Meta-analytic results revealed an optimal cut-score of <= 42 with 54% sensitivity and 93% specificity for identifying invalid neuropsychological test performance. Collectively, the WCT demonstrated adequate diagnostic accuracy as a PVT across a variety of populations. Recommendations for future studies are also provided.
引用
收藏
页码:349 / 359
页数:11
相关论文
共 50 条
[41]   Digital breast tomosynthesis for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis [J].
Mostafa Alabousi ;
Nanxi Zha ;
Jean-Paul Salameh ;
Lucy Samoilov ;
Anahita Dehmoobad Sharifabadi ;
Alex Pozdnyakov ;
Behnam Sadeghirad ;
Vivianne Freitas ;
Matthew D. F. McInnes ;
Abdullah Alabousi .
European Radiology, 2020, 30 :2058-2071
[42]   A step-by-step guide to the systematic review and meta-analysis of diagnostic and prognostic test accuracy evaluations [J].
Liu, Z. ;
Yao, Z. ;
Li, C. ;
Liu, X. ;
Chen, H. ;
Gao, C. .
BRITISH JOURNAL OF CANCER, 2013, 108 (11) :2299-2303
[43]   Meta-analysis of diagnostic test accuracy in neurosurgical practice [J].
Dubourg, Julie ;
Berhouma, Moncef ;
Cotton, Michael ;
Messerer, Mahmoud .
NEUROSURGICAL FOCUS, 2012, 33 (01)
[44]   Comparative Analysis of Diagnostic Techniques for Melanoma Detection: A Systematic Review of Diagnostic Test Accuracy Studies and Meta-Analysis [J].
Blundo, Alessia ;
Cignoni, Arianna ;
Banfi, Tommaso ;
Ciuti, Gastone .
FRONTIERS IN MEDICINE, 2021, 8
[45]   The diagnostic performance of the ductus venosus for the detection of cardiac defects in the first trimester: a systematic review and diagnostic test accuracy meta-analysis [J].
Savoia, Fabiana ;
Scala, Carolina ;
Coppola, Marlene ;
Riemma, Gaetano ;
Vitale, Salvatore Giovanni ;
Mikus, Mislav ;
Schiattarella, Antonio ;
La Verde, Marco ;
Colacurci, Nicola ;
De Franciscis, Pasquale ;
Morlando, Maddalena .
ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2023, 308 (02) :435-451
[46]   The diagnostic performance of the ductus venosus for the detection of cardiac defects in the first trimester: a systematic review and diagnostic test accuracy meta-analysis [J].
Fabiana Savoia ;
Carolina Scala ;
Marlene Coppola ;
Gaetano Riemma ;
Salvatore Giovanni Vitale ;
Mislav Mikuš ;
Antonio Schiattarella ;
Marco La Verde ;
Nicola Colacurci ;
Pasquale De Franciscis ;
Maddalena Morlando .
Archives of Gynecology and Obstetrics, 2023, 308 :435-451
[47]   Diagnostic Test Accuracy of Exercise Testing in Detecting High-Risk Accessory Pathways in WPW: A Systematic Review and Meta-Analysis [J].
de Alencar, Jose Nunes ;
Rassi, Fabio Mahamad ;
Rios, Raquel Pereira ;
Scheffer, Matheus Kiszka ;
de Carvalho, Guilherme Dagostin ;
de Carvalho, Dagostin .
ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2025, 122 (04)
[48]   Direct antiglobulin test for the prediction of neonatal hyperbilirubinemia needing an intervention: a systematic review and diagnostic test accuracy meta-analysis [J].
Krishnegowda, Vijay Kumar ;
Ramaswamy, Viraraghavan Vadakkencherry ;
Abiramalatha, Thangaraj ;
Bandyopadhyay, Tapas ;
Pullattayil, S. Abdul Kareem ;
Loganathan, Prakash Kannan .
FRONTIERS IN PEDIATRICS, 2025, 12
[49]   An Updated Systematic Review and Meta-Analysis for the Diagnostic Test Accuracy of Ascitic Fluid Adenosine Deaminase in Tuberculous Peritonitis [J].
Mahajan, Mayank ;
Prasad, Manohar Lal ;
Kumar, Pramod ;
Kumar, Amit ;
Chatterjee, Neha ;
Singh, Shreya ;
Marandi, Sujeet ;
Prasad, Manoj Kumar .
INFECTION AND CHEMOTHERAPY, 2023, 55 (02) :264-277
[50]   Diagnosis of Alzheimer's Disease in Developed and Developing Countries: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy [J].
Chavez-Fumagalli, Miguel A. ;
Shrivastava, Pallavi ;
Aguilar-Pineda, Jorge A. ;
Nieto-Montesinos, Rita ;
Davila Del-Carpio, Gonzalo ;
Peralta-Mestas, Antero ;
Caracela-Zeballos, Claudia ;
Valdez-Lazo, Guillermo ;
Fernandez-Macedo, Victor ;
Pino-Figueroa, Alejandro ;
Vera-Lopez, Karin J. ;
Lino Cardenas, Christian L. .
JOURNAL OF ALZHEIMERS DISEASE REPORTS, 2021, 5 (01) :15-30