A Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the Advanced Clinical Solutions Word Choice Test as a Performance Validity Test

被引:37
作者
Bernstein, Matthew T. [1 ]
Resch, Zachary J. [1 ,2 ]
Ovsiew, Gabriel P. [1 ]
Soble, Jason R. [1 ,3 ]
机构
[1] Univ Illinois, Coll Med, Dept Psychiat, Chicago, IL 60607 USA
[2] Rosalind Franklin Univ Med & Sci, Dept Psychol, N Chicago, IL 60064 USA
[3] Univ Illinois, Coll Med, Dept Neurol, Chicago, IL USA
关键词
Word choice test; WCT; Performance validity; Diagnostic accuracy; Systematic review; Meta-analysis; RECOGNITION MEMORY TEST; CLASSIFICATION ACCURACY; INADEQUATE EFFORT; HETEROGENEITY; INDEXES; TRIAL;
D O I
10.1007/s11065-020-09468-y
中图分类号
B849 [应用心理学];
学科分类号
040203 ;
摘要
Thorough assessment of performance validity has become an established standard of practice in neuropsychological assessment. While there has been a large focus on the development and cross-validation of embedded performance validity tests (PVTs) in recent years, new freestanding PVTs have also been developed, including the Word Choice Test (WCT) as part of the Advanced Clinical Solutions Effort System. And, while the WCT's general utility for identifying invalid performance has been demonstrated in the ensuing decade since its initial publication, optimal cut-scores and associated psychometric properties have varied widely across studies. This study sought to synthesize the existing diagnostic accuracy literature regarding the WCT via a systematic review and to conduct a meta-analysis to determine the performance validity cut-score that best maximizes sensitivity while maintaining acceptable specificity. A systematic search of the literature resulted in 14 studies for synthesis, with eight of those available for meta-analysis. Meta-analytic results revealed an optimal cut-score of <= 42 with 54% sensitivity and 93% specificity for identifying invalid neuropsychological test performance. Collectively, the WCT demonstrated adequate diagnostic accuracy as a PVT across a variety of populations. Recommendations for future studies are also provided.
引用
收藏
页码:349 / 359
页数:11
相关论文
共 50 条
[21]   A simple plaster for screening for diabetic neuropathy: A diagnostic test accuracy systematic review and meta-analysis [J].
Tsapas, Apostolos ;
Liakos, Aris ;
Paschos, Paschalis ;
Karagiannis, Thomas ;
Bekiari, Eleni ;
Tentolouris, Nikolaos ;
Boura, Panagiota .
METABOLISM-CLINICAL AND EXPERIMENTAL, 2014, 63 (04) :584-592
[22]   Evaluating Rabies Test Accuracy: A Systematic Review and Meta-Analysis of Human and Canine Diagnostic Methods [J].
Candia-Puma, Mayron Antonio ;
Pola-Romero, Leydi ;
Barazorda-Ccahuana, Haruna Luz ;
Goyzueta-Mamani, Luis Daniel ;
Galdino, Alexsandro Sobreira ;
Machado-de-avila, Ricardo Andrez ;
Giunchetti, Rodolfo Cordeiro ;
Coelho, Eduardo Antonio Ferraz ;
Chavez-Fumagalli, Miguel Angel .
DIAGNOSTICS, 2025, 15 (04)
[23]   Diagnostic Accuracy of Fecal Elastase-1 Test for Pancreatic Exocrine Insufficiency: A Systematic Review and Meta-Analysis [J].
de la Iglesia, Daniel ;
Agudo-Castillo, Belen ;
Galego-Fernandez, Marco ;
Rama-Fernandez, Alberto ;
Dominguez-Munoz, J. Enrique .
UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2025,
[24]   DWI for Renal Mass Characterization: Systematic Review and Meta-Analysis of Diagnostic Test Performance [J].
Kang, Stella K. ;
Zhang, Angela ;
Pandharipande, Pari V. ;
Chandarana, Hersh ;
Braithwaite, R. Scott ;
Littenberg, Benjamin .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) :317-324
[25]   Physical examination tests of the shoulder: a systematic review and meta-analysis of diagnostic test performance [J].
Gismervik, Sigmund O. ;
Drogset, Jon O. ;
Granviken, Fredrik ;
Ro, Magne ;
Leivseth, Gunnar .
BMC MUSCULOSKELETAL DISORDERS, 2017, 18
[26]   Diagnostic Accuracy of Clinical Tests for Subscapularis Tears: A Systematic Review and Meta-analysis [J].
Ladermann, Alexandre ;
Collin, Philippe ;
Zbinden, Olivia ;
Meynard, Timon ;
Saffarini, Mo ;
Chiu, Joe Chih-Hao .
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (09)
[27]   Physical examination tests of the shoulder: a systematic review and meta-analysis of diagnostic test performance [J].
Sigmund Ø. Gismervik ;
Jon O. Drogset ;
Fredrik Granviken ;
Magne Rø ;
Gunnar Leivseth .
BMC Musculoskeletal Disorders, 18
[28]   Diagnostic Accuracy of BRAF Immunohistochemistry in Colorectal Cancer: a Meta-Analysis and Diagnostic Test Accuracy Review [J].
Pyo, Jung-Soo ;
Sohn, Jin Hee ;
Kang, Guhyun .
PATHOLOGY & ONCOLOGY RESEARCH, 2016, 22 (04) :831-837
[29]   A systematic review with meta-analysis of the diagnostic test accuracy of pedicle screw electrical stimulation [J].
Fonseca, Pedro ;
Goethel, Marcio ;
Vilas-Boas, Joao Paulo ;
Gutierres, Manuel ;
Correia, Miguel Velhote .
EUROPEAN SPINE JOURNAL, 2022, 31 (07) :1599-1610
[30]   Blood biomarkers for sarcopenia: A systematic review and meta-analysis of diagnostic test accuracy studies [J].
Lian, Rongna ;
Liu, Qianqian ;
Jiang, Gengchen ;
Zhang, Xiangyu ;
Tang, Huiyu ;
Lu, Jing ;
Yang, Ming .
AGEING RESEARCH REVIEWS, 2024, 93