Use of potassium-form cation-exchange resin as a conductimetric enhancer in ion-exclusion chromatography of aliphatic carboxylic acids

被引:13
|
作者
Iwata, Tomotaka [1 ]
Mori, Masanobu [1 ]
Itabashi, Hideyuki [1 ]
Tanaka, Kazuhiko [2 ]
机构
[1] Gunma Univ, Grad Sch Engn, Gunma 3768515, Japan
[2] Hiroshima Univ, Grad Sch Int Dev & Cooperat, Higashihiroshima 7398529, Japan
基金
日本学术振兴会;
关键词
Ion-exclusion chromatography; Conductimetric enhancer; Cation exchange; Aliphatic carboxylic acids; CONDUCTIVITY DETECTION; COLUMN;
D O I
10.1016/j.talanta.2009.03.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a cation-exchange resin (CEX) of the W-form, i.e., an enhancer resin, is used as a postcolumn conductimetric enhancer in the ion-exclusion chromatography of aliphatic carboxylic acids. The enhancer resin is filled in the switching valve of an ion chromatograph; this valve is usually used as a suppressor valve in ion-exchange chromatography. An aliphatic carboxylic acid (e.g.,CH3COOH) separated by a weakly acidic CEX column of the H+-form converts into that of the K+-form (e.g., CH3COCK) by passing through the enhancer resin. In contrast, the background conductivity decreases because a strong acid (e.g., HNO3) with a higher conductimetric response in an eluent converts into a salt (e.g., KNO3 with a lower conductimetric response. Since the pH of the eluent containing the resin enhancer increases from 3.27 to 5.85, the enhancer accelerates the dissociations of analyte acids. Consequently, peak heights and peak areas of aliphatic carboxylic acids (e.g., acetic acid, propionic acid, butyric acid, and valeric acid) with the enhancer resin are 6.3-8.0 times higher and 7.2-9.2 times larger, respectively, than those without the enhancer resin. Calibrations of peak areas for injected analytes are linear in the concentration range of 0.01-1.0 mM.The detection limits (signal-to-noise ratio = 3) range from 0.10 mu M to 0.39 mu M in this system, as opposed to those in the range of 0.24-7.1 mu M in the separation column alone. The developed system is successfully applied to the determination of aliphatic carboxylic acids in a chicken droppings sample. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1026 / 1030
页数:5
相关论文
共 50 条
  • [21] SIMULTANEOUS ION-EXCLUSION CHROMATOGRAPHY CATION-EXCHANGE CHROMATOGRAPHY WITH CONDUCTIMETRIC DETECTION OF ANIONS AND CATIONS IN ACID-RAIN WATERS
    TANAKA, K
    OHTA, K
    FRITZ, JS
    MATSUSHITA, S
    MIYANAGA, A
    JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) : 239 - 248
  • [22] Use of a Polystyrene-divinylbenzene-based Weakly Acidic Cation-Exchange Resin Column and Propionic Acid as an Eluent in Ion-Exclusion/Adsorption Chromatography of Aliphatic Carboxylic Acids and Ethanol in Food Samples
    Mori, Masanobu
    Hironaga, Takahiro
    Kajiwara, Hiroe
    Nakatani, Nobutake
    Kozaki, Daisuke
    Itabashi, Hideyuki
    Tanaka, Kazuhiko
    ANALYTICAL SCIENCES, 2011, 27 (05) : 505 - 510
  • [23] Use of a Polystyrene-divinylbenzene-based Weakly Acidic Cation-Exchange Resin Column and Propionic Acid as an Eluent in Ion-Exclusion/Adsorption Chromatography of Aliphatic Carboxylic Acids and Ethanol in Food Samples
    Masanobu Mori
    Takahiro Hironaga
    Hiroe Kajiwara
    Nobutake Nakatani
    Daisuke Kozaki
    Hideyuki Itabashi
    Kazuhiko Tanaka
    Analytical Sciences, 2011, 27 : 505 - 510
  • [24] Ion-exclusion chromatography of organic acids: Regularities in the retention of aliphatic carboxylic acids
    Medved, AL
    Ivanov, AA
    Shpigun, OA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 51 (10) : 964 - 971
  • [26] ION-EXCLUSION CHROMATOGRAPHY OF CARBOXYLIC-ACIDS WITH CONDUCTIMETRIC ESTIMATION .1. METHODOLOGY
    MONK, PR
    ILAND, PG
    FOOD TECHNOLOGY IN AUSTRALIA, 1984, 36 (01): : 16 - 17
  • [27] Simultaneous determination of anions and cations in natural water by ion-exclusion/cation-exchange chromatography with a weakly acidic cation-exchange resin column
    Lee, KP
    Choi, SH
    Park, YC
    Bae, ZU
    Lee, MS
    Lee, SH
    Chang, HY
    Kwon, SM
    Tanaka, K
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (09) : 1324 - 1328
  • [28] High-speed simultaneous ion-exclusion/cation-exchange chromatography of anions and cations on a weakly acidic cation-exchange resin column
    Mori, M
    Tanaka, K
    Helaleh, MIH
    Xu, Q
    Ikedo, M
    Ogura, Y
    Sato, S
    Hu, WZ
    Hasebe, K
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 219 - 224
  • [29] Influence of acidic eluent for retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography on a weakly acidic cation-exchange resin in the H+-form
    Mori, Masanobu
    Tanaka, Kazuhiko
    Satori, Tatsuya
    Ikedo, Mikaru
    Hu, Wenzhi
    Itabashi, Hideyuki
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1118 (01) : 51 - 55
  • [30] ION EXCLUSION CHROMATOGRAPHY OF PHOSPHATE ION USING CATION-EXCHANGE RESIN
    TANAKA, K
    NAKAJIMA, K
    SUNAHARA, H
    BUNSEKI KAGAKU, 1977, 26 (02) : 102 - 106