A non-contact laser speckle sensor for the measurement of robotic tool speed

被引:21
|
作者
Charrett, Thomas O. H. [1 ]
Bandari, Yashwanth K. [2 ]
Michel, Florent [2 ]
Ding, Jialuo [2 ]
Williams, Stewart W. [2 ]
Tatam, Ralph P. [1 ]
机构
[1] Cranfield Univ, Ctr Engn Photon, Cranfield MK43 0AL, Beds, England
[2] Cranfield Univ, Welding Engn & Laser Proc Ctr, Cranfield MK43 0AL, Beds, England
基金
英国工程与自然科学研究理事会;
关键词
Laser speckle; Tool speed; Velocimetry; Robotic sensor; DISPLACEMENT; DECORRELATION;
D O I
10.1016/j.rcim.2018.04.007
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A non-contact speckle correlation sensor for the measurement of robotic tool speed is described that is capable of measuring the in-plane relative velocities between a robot end-effector and the workplace or other surface. The sensor performance has been assessed in the laboratory with sensor accuracies of +/- 0.01 mm/s over a +/- 70 mm/s velocity range. The effect of misalignment of the sensor on the robot was assessed for variation in both working distance and angular alignment with sensor accuracy maintained to within 0.025 mm/s (< 0.04%) over a working distance variation of +/- 5 mm from the sensor design distance and +/- 0.4 mm/s (0.6%) for a misalignment of 5 degrees. The sensor precision was found to be limited by the peak fitting accuracy used in the signal processing with peak errors of +/- 0.34 mm/s. Finally an example of the sensor's application to robotic manufacturing is presented where the sensor was applied to tool speed measurement for path planning in the wire and arc additive manufacturing process using a KUKA KR150 L110/2 industrial robot.
引用
收藏
页码:187 / 196
页数:10
相关论文
共 50 条
  • [21] A non-contact laser probe in industrial measurement
    Li, Y
    Zhang, LX
    Zhang, SL
    Han, YM
    1999 INTERNATIONAL CONFERENCE ON INDUSTRIAL LASERS (IL'99), 1999, 3862 : 306 - 310
  • [22] Non-contact temperature measurement by laser technology
    Huang, Fang
    Liu, Xiangxin
    Han, Junfeng
    Wang, Jing
    Li, Hui
    Wang, Wenjing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2013, 33 (07): : 642 - 646
  • [23] ALTERNATIVE TO LASER VIBROMETERS: A NON-CONTACT VIBRATION MEASUREMENT BASED ON ENHANCED LASER SPECKLE PATTERN AND STROBOSCOPIC SAMPLING
    Yildiz, Ibrahim
    METROLOGY AND MEASUREMENT SYSTEMS, 2024, 31 (04) : 767 - 779
  • [24] NON-CONTACT SPEED MEASUREMENT - COMPARISON OF OPTICAL SYSTEMS
    FRITSCHE, R
    MESCH, F
    MEASUREMENT AND CONTROL, 1973, 6 (07): : 293 - 300
  • [25] Non-contact laser speckle sensor for measuring one- and two-dimensional angular displacement
    Rose, B
    Imam, H
    Hanson, SG
    JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1998, 29 (03): : 115 - 120
  • [26] Non-contact Measurement of the Heart Rate by a Image Sensor
    Bernacchia, Natascia
    Marchionni, Paolo
    Ercoli, Ilaria
    Scalise, Lorenzo
    SENSORS, 2015, 319 : 371 - 375
  • [27] Non-contact measurement of eyeblink by using Doppler sensor
    Maleki, Amir
    Uchida, Masafumi
    ARTIFICIAL LIFE AND ROBOTICS, 2018, 23 (02) : 279 - 285
  • [28] High Accuracy and Wide Temperature Measurement by Non-Contact Speckle Extensometer
    Kobayashi, K.
    Yamaguchi, I.
    STRAIN, 2011, 47 : E98 - E103
  • [29] Non-contact photoacoustic imaging using laser speckle contrast analysis
    Benyaniin, Matan
    Genish, Hadar
    Califa, Ran
    Schwartz, Ariel
    Zalevsky, Zeev
    Ozana, Nisan
    OPTICS LETTERS, 2019, 44 (12) : 3110 - 3113
  • [30] NON-CONTACT STRIP SPEED MEASUREMENT USING AN ELECTROSTATIC SENSOR ARRAY AND DATA FUSION TECHNIQUE
    Wang Xiaoyu
    Hu Yonghui
    Qian Xiangchen
    Wang Lijuan
    Yan Yong
    2014 12TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP), 2014, : 363 - 367