Differences in Recognition of the 1st WHO International Reference Reagents for hCG-Related Isoforms by Diagnostic Immunoassays for Human Chorionic Gonadotropin

被引:98
作者
Sturgeon, Catharine M. [1 ]
Berger, Peter [2 ]
Bidart, Jean-Michel [3 ]
Birken, Steven [4 ]
Burns, Chris [5 ]
Norman, Robert J. [6 ]
Stenman, Ulf-Hakan [7 ]
机构
[1] Royal Infirm Edinburgh NHS Trust, Dept Clin Biochem, Edinburgh EH16 4SA, Midlothian, Scotland
[2] Austrian Acad Sci, Inst Biomed Aging Res, Innsbruck, Austria
[3] Inst Gustave Roussy, Dept Biol Clin, F-94805 Villejuif, France
[4] Columbia Univ, Coll Phys & Surg, Dept Obstet & Gynecol, New York, NY 10027 USA
[5] Natl Inst Biol Stand & Controls, Potters Bar EN6 3QG, Herts, England
[6] Univ Adelaide, Queen Elizabeth Hosp, Res Ctr Reprod Hlth, Dept Obstet & Gynaecol, Woodville, SA 5011, Australia
[7] Univ Helsinki, Cent Hosp, Dept Clin Chem, FIN-00014 Helsinki, Finland
关键词
FREE BETA-SUBUNIT; HUMAN CHORIOGONADOTROPIN; CORE FRAGMENT; SERUM; URINE; ASSAY; STANDARDIZATION; ASSIGNMENT; PREGNANCY; SYSTEMS;
D O I
10.1373/clinchem.2009.124578
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: The 1st WHO International Reference Reagents (IRRs) for 6 human chorionic gonadotropin (hCG)-related molecular variants, highly purified and calibrated in substance concentrations by the IFCC Working Group for hCG, permit experimental elucidation of what commercially available hCG methods measure in molar terms and enable assessment of their fitness for clinical purposes. METHODS: Pools containing known amounts of the IRRs spiked into normal human serum were issued to participants through the UK National External Quality Assessment Service for hCG for a period of 7 years. Among 16 assays used, 4 recognized only hCG, whereas 6 recognized hCG and its free beta-subunit (hCG beta), and 6 recognized hCG, hCG beta, and the beta core fragment. RESULTS: Differences in calibration of current hCG assays are moderate. Mean recovery of the current International Standard (IS), hCG IS 75/589, was 107% (range 93% to 126%), whereas that of the IRR 99/688 for hCG was 139% (range 109%-164%). Between-method variation for the latter (CV 12.3%) was a so greater than for IS 75/589 (CV 8.8%). Recognition of hCG beta varied markedly (CV 37%). Most assays overestimated it, but 2 RIAs produced results that were slight underestimations. Recognition of the beta core fragment was even more variable (CV 57%) and was closest to equimolarity for the RIAs. CONCLUSIONS: Assays for hCG show considerable variation in their recognition of various forms of hCG, and this variablility is the most important cause of method-related differences in hCG results in serum and an even more important cause of method-related differences in urine measurements. Equimolar recognition of the major hCG isoforms is essential if between-method comparability for hCG is to be improved. (C) 2009 American Association for Clinical Chemistry
引用
收藏
页码:1484 / 1491
页数:8
相关论文
共 26 条
[1]  
ALFTHAN H, 1992, CLIN CHEM, V38, P1981
[2]  
ALFTHAN H, 1992, CANCER RES, V52, P4628
[3]   The ISOBM TD-7 workshop on hCG and related molecules - Towards user-oriented standardization of pregnancy and tumor diagnosis: Assignment of epitopes to the three-dimensional structure of diagnostically and commercially relevant monoclonal antibodies directed against human chorionic gonadotropin and derivatives [J].
Berger, P ;
Sturgeon, C ;
Bidart, JM ;
Paus, E ;
Gerth, R ;
Niang, M ;
Bristow, A ;
Birken, S ;
Stenman, UH .
TUMOR BIOLOGY, 2002, 23 (01) :1-38
[4]  
BERGER P, 2008, EXPERT OPINION, V2, P1237
[5]   Preparation and characterization of new WHO reference reagents for human chorionic gonadotropin and metabolites [J].
Birken, S ;
Berger, P ;
Bidart, JM ;
Weber, M ;
Bristow, A ;
Norman, RJ ;
Sturgeon, C ;
Stenman, UH .
CLINICAL CHEMISTRY, 2003, 49 (01) :144-154
[6]   Establishment, value assignment, and characterization of new WHO reference reagents for six molecular forms of human chorionic gonadotropin [J].
Bristow, A ;
Berger, P ;
Bidart, JM ;
Birken, S ;
Norman, RJ ;
Stenman, UH ;
Sturgeon, C .
CLINICAL CHEMISTRY, 2005, 51 (01) :177-182
[7]   Are laboratories reporting serum quantitative hCG results correctly? [J].
Cao, Zhimin Tim ;
Rej, Robert .
CLINICAL CHEMISTRY, 2008, 54 (04) :761-764
[8]  
COLE LA, 1992, CLIN CHEM, V38, P263
[9]   Between-method variation in human chorionic gonadotropin test results [J].
Cole, LA ;
Sutton, JM ;
Higgins, TNM ;
Cembrowski, GS .
CLINICAL CHEMISTRY, 2004, 50 (05) :874-882
[10]   Gestational trophoblastic diseases: 2. Hyperglycosylated hCG as a reliable marker of active neoplasia [J].
Cole, Laurence A. ;
Butler, Stephen A. ;
Khanlian, Sarah A. ;
Giddings, Almareena ;
Muller, Carolyn Y. ;
Seckl, Michael J. ;
Kohorn, Ernest I. .
GYNECOLOGIC ONCOLOGY, 2006, 102 (02) :151-159