Numerical study on the convective heat transfer of fattening pig in groups in a mechanical ventilated pig house

被引:25
作者
Li, Hao [1 ]
Rong, Li [1 ]
Zhang, Guoqiang [1 ]
机构
[1] Aarhus Univ, Dept Engn, Blichers Alle 20,POB 50, DK-8830 Tjele, Denmark
关键词
Pig house; Convective heat transfer coefficients; Air inlet; Air velocity; CFD simulation; COMPUTATIONAL FLUID-DYNAMICS; AIR-FLOW; TURBULENCE MODELS; CFD; LIVESTOCK; TEMPERATURE; PREDICTION; BUILDINGS; ANIMALS; SYSTEMS;
D O I
10.1016/j.compag.2017.08.013
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
It is recognized that increasing the local air speed in the animal occupied zone (AOZ) is one of the effective approaches to decrease the heat stress of pigs. To predict the effects of the air speed in an AOZ, knowledge of the relationship between convective heat loss and air speed is essential. In this study, the convective heat losses from pig models were modelled through numerical simulation under semi-practical conditions. The convective heat transfer coefficients of pigs in groups were tested at different inlet speeds. Virtual pig bodies (pig models) corresponding to three different body weights, i.e., 30 kg, 50 kg, and 80 kg, were generated and used in the investigation. Two wall inlet styles, a conventional inlet with an upward guiding plate and a modified inlet that supplied downward airflow directly onto the pigs, were compared to estimate the effect of ventilation system on the convective heat loss of pigs. The results showed that convective heat transfer coefficients of pigs in a group were strongly correlated with the inlet air speeds as well as the reference air speed in the AOZ (the average air speed in AOZ was selected as reference air speed in this study). The weight of the pig models showed no significant effect on the convective heat transfer coefficient. The convective heat transfer coefficient of the pigs in pens with the downward inlet was averagely 60.4% higher than those with the upward inlet. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 100
页数:11
相关论文
共 30 条
  • [1] Ansys, 2013, ANSYS FLUENT US GUID
  • [2] Analysis of airflow through experimental rural buildings: Sensitivity to turbulence models
    Bartzanas, T.
    Kittas, C.
    Sapounas, A. A.
    Nikita-Martzopoulou, Ch.
    [J]. BIOSYSTEMS ENGINEERING, 2007, 97 (02) : 229 - 239
  • [3] Bjerg B, 2013, ACTA HORTIC, V1008, P143
  • [4] Bjerg Bjarne, 2011, Chemistry, Emission Control, Radioactive Pollution and Indoor Air Quality, P639
  • [5] Modeling of air inlets in CFD prediction of airflow in ventilated animal houses
    Bjerg, B
    Svidt, K
    Zhang, G
    Morsing, S
    Johnsen, JO
    [J]. COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2002, 34 (1-3) : 223 - 235
  • [6] Modelling of ammonia emissions from naturally ventilated livestock buildings. Part 3: CFD modelling
    Bjerg, Bjarne
    Cascone, Giovanni
    Lee, In-Bok
    Bartzanas, Thomas
    Norton, Tomas
    Hong, Se-Woon
    Seo, Il-Hwan
    Banhazi, Thomas
    Liberati, Paolo
    Marucci, Alvaro
    Zhang, Guoqiang
    [J]. BIOSYSTEMS ENGINEERING, 2013, 116 (03) : 259 - 275
  • [7] Brody S., 1928, MO AGR EXP STA B, V115
  • [8] Convective heat transfer coefficients for exterior building surfaces: Existing correlations and CFD modelling
    Defraeye, Thijs
    Blocken, Bert
    Carmeliet, Jan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) : 512 - 522
  • [10] Johnson J.S., 2015, Climate change impact on livestock: adaptation and mitigation, P61, DOI DOI 10.1007/978-81-322-2265-1_5