Optimization of non-evacuated receiver of solar collector having non-uniform temperature distribution for minimum heat loss

被引:34
作者
Patil, Ramchandra G. [1 ]
Panse, Sudhir V. [1 ]
Joshi, Jyeshtharaj B. [1 ,2 ]
机构
[1] Inst Chem Technol, Bombay 400019, Maharashtra, India
[2] Homi Bhabha Natl Inst, Bombay 400094, Maharashtra, India
关键词
Solar collector receiver; Non-evacuated receivers; Non-uniform temperature distribution; Heat loss; PARABOLIC TROUGH COLLECTOR; CRITICAL IMPELLER SPEED; NATURAL-CONVECTION; SOLID SUSPENSION; WIND FLOW; NUMERICAL-SIMULATION; AGITATED CONTACTORS; TUBULAR ABSORBER; STEAM; PERFORMANCE;
D O I
10.1016/j.enconman.2014.05.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present paper contains a numerical study of heat loss from a non-evacuated receiver typically used in parabolic trough collectors. To calculate temperature distributions on the receiver pipe (T-P), an energy balance has been established over the entire cross-section of the receiver pipe at different fluid temperatures. In the energy balance, the flux distribution has been estimated by assuming normal incidence of solar insolation considering the sun as a point source. The temperature distributions of the receiver pipe are found, as per expectation, to be non-uniform. These temperature distributions have been fitted by sinusoidal and step functions and are used as temperature boundary conditions in a CFD study to optimize the size of the receiver. The mechanisms of heat loss that have been considered in this study are heat loss from (1) pipe to glass tube by conduction, convection and radiation and (2) glass tube to surrounding by convection (natural and forced) and radiation. The values of diameters of receiver pipe taken in this study are 33 mm, 48 mm, 60 mm, 70 mm, 89 mm and 102 mm. The radius ratio (RR) varied from 1.2 to 3 by changing diameter of glass tube. It is observed that, the critical value of RR for minimum heat loss is dependent upon receiver pipe diameter (D-PO). The critical values of RR for pipe diameter (D-PO) 33 mm, 48 mm, 60 mm, 70 mm, 89 mm and 102 mm are 1.5, 1.4, 1.375, 1.35, 1.3 and 1.25 respectively. The value of critical RR is lower for higher values of pipe diameter. The value of critical RR for a particular diameter of receiver is independent of receiver temperature and external wind velocity. Comparison of heat losses in non-uniform and uniform temperature cases shows that the values of heat losses in the two cases differ only by 1.5%. (c) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 84
页数:15
相关论文
共 53 条
[1]   Numerical study of conduction and convection heat losses from a half-insulated air-filled annulus of the receiver of a parabolic trough collector [J].
Al-Ansary, Hany ;
Zeitoun, O. .
SOLAR ENERGY, 2011, 85 (11) :3036-3045
[2]  
Alshahrani D, 2005, ALEXANDRIA ENG J, V44, P813
[3]  
[Anonymous], 6 INT SUMM SCH KLAG
[4]  
[Anonymous], 1994, SANDIA941884 SAND NA
[5]   CALCULATION OF TUBULAR ABSORBER HEAT-LOSS FACTOR [J].
BHOWMIK, NC ;
MULLICK, SC .
SOLAR ENERGY, 1985, 35 (03) :219-225
[6]   Numerical investigation of parabolic trough receiver performance with outer vacuum shell [J].
Daniel, Premjit ;
Joshi, Yashavant ;
Das, Abhik K. .
SOLAR ENERGY, 2011, 85 (09) :1910-1914
[7]  
EISherbiny S. M., 2004, ALEX ENG J, V43, P297
[8]  
Fluent, 2004, FLUENT 6 2 US GUID
[9]  
Foristall R, 2003, HEAT TRANSFER ANAL M
[10]  
Francis D, 1991, SOLAR COLLECTORS ENE