Experiments and simulation of mass flux measurement of supercritical water by orifice plate

被引:0
作者
Li Wenkai [1 ]
Wang Wei [1 ]
Wu Yuxin [1 ]
Lu Junfu [1 ]
机构
[1] Tsinghua Univ, Minist Educ, Key Lab Thermal Sci & Power Engn, Dept Thermal Engn, Beijing, Peoples R China
来源
2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC) | 2010年
关键词
orifice plate; supercritical water; discharge coefficient; Fluent;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
It's difficult to measure the flux of supercritical water because of its high temperature and pressure. With a example of supercritical water with a pressure of 25 Mpa in tube (inner diameter = 37 mm), experiments and simulation were taken to study the mass flux measurement by orifice flowmeter. At normal atmosphere, the orifice plate is demarcated by weighing method, and then simulated by Fluent software, so the reliability of simulation can be checked. At supercritical pressures, a series of conditions with different temperatures and pressures were simulated by Fluent software, and then characteristics of the orifice discharge coefficient were studied.
引用
收藏
页数:4
相关论文
共 3 条
[1]  
[陈家庆 CHEN Jiaqing], 2008, [实验流体力学, Journal of Experiments in Fluid Mechanics], V22, P51
[2]  
[程勇 Cheng Yong], 2005, [计量学报, Acta Metrologica Sinica], V26, P57
[3]  
Gao Song-wei, 2009, Journal of Shenyang University of Technology, V31, P84