Stereo-Acuity in Patients Implanted with Multifocal Intraocular Lenses: Is the Choice of Stereotest Relevant?

被引:7
|
作者
Varon, Consuelo [1 ]
Gil, Miguel A. [2 ]
Alba-Bueno, Francisco [1 ]
Cardona, Genis [1 ]
Vega, Fidel [1 ]
Millan, Maria S. [1 ]
Buil, Jose A. [2 ]
机构
[1] Tech Univ Catalonia, Dept Opt & Optometry, Terrassa, Spain
[2] Santa Creu & St Pau Hosp, Barcelona, Spain
关键词
Cataract surgery; chromatic aberration; diffractive optics; multifocal intraocular lens; stereo-acuity; BILATERAL IMPLANTATION; PSEUDOPHAKIC PATIENTS; VISUAL PERFORMANCE; ANISEIKONIA; CONTRAST; SIZE;
D O I
10.3109/02713683.2013.865758
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: A randomized and double-blinded study design was implemented to assess the stereo-acuity in patients symmetrically implanted with four types of multifocal intraocular lenses (MIOLs), compared to a monofocal lens (control group). In addition, the influence of the type of test employed for the evaluation of stereo-acuity was explored. Materials and Methods: Six months after cataract intervention, stereo-acuity was measured with the Titmus and TNO stereotests in 143 patients implanted with one of the following MIOL lens types: hybrid spherical SN60D3, hybrid aspheric SN6AD1, diffractive aspheric ZMA00 and refractive spherical NXG1. A control group implanted with the monofocal aspheric ZA9003 (in which stereo-acuity was measured with a near addition) was also included in the study. Results: Statistically significant better stereo-acuity was found in the monofocal group with both stereotests (except for the SN60D3 group with the Titmus test) (all p<0.001). No significant differences in stereo-acuity between MIOLs were found using the Titmus test. However, with the TNO, patients implanted with hybrid diffractive MIOLs exhibited statistically significant worse stereo-acuity than those with the refractive design (SN60D3, p<0.001; SN6AD1, p = 0.006). Conclusions: Patients implanted with MIOLs have worse stereo-acuity than those implanted with monofocal IOLs due to the decrease in retinal image contrast originating in the simultaneous presence of two images. Awavelength-based stereotest such as the TNO induces large differences in image contrast between fellow eyes implanted with diffractive-based MIOLs, which may result in an underestimation of the real stereo-acuity of the patient.
引用
收藏
页码:711 / 719
页数:9
相关论文
共 38 条
  • [31] Long-Term Refractive Outcomes and Visual Quality of Multifocal Intraocular Lenses Implantation in High Myopic Patients: A Multimodal Evaluation
    Castro, Catarina
    Ribeiro, Bruno
    Couto, Ines Maria Campos
    Abreu, Ana Carolina
    Monteiro, Silvia
    Pinto, Maria do Ceu
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 365 - 375
  • [32] Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses
    Cillino, Giovanni
    Casuccio, Alessandra
    Pasti, Mattia
    Bono, Valeria
    Mencucci, Rita
    Cillino, Salvatore
    OPHTHALMOLOGY, 2014, 121 (01) : 34 - 44
  • [33] Risk factors in self-reported dissatisfied patients implanted with various presbyopia-correcting intraocular lenses after cataract surgery
    Jeon, Woosung
    Yoon, Chang Ho
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [34] Analysis of contrast sensitivity in patients implanted with Acunex Vario and LuxSmart extended depth of focus (E-DOF) intraocular lenses (IOLs)
    Irinkova, Boryana
    Kuneva, Irina
    Petkova, Iva
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2024, 38 (01)
  • [35] Randomised placebo-controlled clinical trial evaluating the impact of a new visual rehabilitation program on neuroadaptation in patients implanted with trifocal intraocular lenses
    Pinero, David P.
    Maldonado-Lopez, Miguel J.
    Molina-Martin, Ainhoa
    Garcia-Sanchez, Noelia
    Ramon, Maria L.
    Rincon, Jose L.
    Holgueras, Alfredo
    Arenillas, Juan F.
    Planchuelo-Gomez, Alvaro
    Leal-Vega, Luis
    Coco-Martin, Maria Begona
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4035 - 4053
  • [36] Randomised placebo-controlled clinical trial evaluating the impact of a new visual rehabilitation program on neuroadaptation in patients implanted with trifocal intraocular lenses
    David P. Piñero
    Miguel J. Maldonado-López
    Ainhoa Molina-Martin
    Noelia García-Sánchez
    María L. Ramón
    José L. Rincón
    Alfredo Holgueras
    Juan F. Arenillas
    Álvaro Planchuelo-Gómez
    Luis Leal-Vega
    María Begoña Coco-Martín
    International Ophthalmology, 2023, 43 : 4035 - 4053
  • [37] Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses
    Singh, Gagandeep
    Sidhharthan, K. S.
    Reddy, Jagadeesh K.
    Sundaram, Vandana
    Thulasidas, Mithun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (02) : 181 - 184
  • [38] Spectacle Independence after Cataract Extraction in Post-Radial Keratotomy Patients Using Hybrid Monovision with ReSTOR (R) Multifocal and TECNIS (R) Monofocal Intraocular Lenses
    Gupta, Isha
    Oakey, Zack
    Ahmed, Faisal
    Ambati, Balamurali K.
    CASE REPORTS IN OPHTHALMOLOGY, 2014, 5 (02): : 157 - 161