Stereo-Acuity in Patients Implanted with Multifocal Intraocular Lenses: Is the Choice of Stereotest Relevant?

被引:7
|
作者
Varon, Consuelo [1 ]
Gil, Miguel A. [2 ]
Alba-Bueno, Francisco [1 ]
Cardona, Genis [1 ]
Vega, Fidel [1 ]
Millan, Maria S. [1 ]
Buil, Jose A. [2 ]
机构
[1] Tech Univ Catalonia, Dept Opt & Optometry, Terrassa, Spain
[2] Santa Creu & St Pau Hosp, Barcelona, Spain
关键词
Cataract surgery; chromatic aberration; diffractive optics; multifocal intraocular lens; stereo-acuity; BILATERAL IMPLANTATION; PSEUDOPHAKIC PATIENTS; VISUAL PERFORMANCE; ANISEIKONIA; CONTRAST; SIZE;
D O I
10.3109/02713683.2013.865758
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: A randomized and double-blinded study design was implemented to assess the stereo-acuity in patients symmetrically implanted with four types of multifocal intraocular lenses (MIOLs), compared to a monofocal lens (control group). In addition, the influence of the type of test employed for the evaluation of stereo-acuity was explored. Materials and Methods: Six months after cataract intervention, stereo-acuity was measured with the Titmus and TNO stereotests in 143 patients implanted with one of the following MIOL lens types: hybrid spherical SN60D3, hybrid aspheric SN6AD1, diffractive aspheric ZMA00 and refractive spherical NXG1. A control group implanted with the monofocal aspheric ZA9003 (in which stereo-acuity was measured with a near addition) was also included in the study. Results: Statistically significant better stereo-acuity was found in the monofocal group with both stereotests (except for the SN60D3 group with the Titmus test) (all p<0.001). No significant differences in stereo-acuity between MIOLs were found using the Titmus test. However, with the TNO, patients implanted with hybrid diffractive MIOLs exhibited statistically significant worse stereo-acuity than those with the refractive design (SN60D3, p<0.001; SN6AD1, p = 0.006). Conclusions: Patients implanted with MIOLs have worse stereo-acuity than those implanted with monofocal IOLs due to the decrease in retinal image contrast originating in the simultaneous presence of two images. Awavelength-based stereotest such as the TNO induces large differences in image contrast between fellow eyes implanted with diffractive-based MIOLs, which may result in an underestimation of the real stereo-acuity of the patient.
引用
收藏
页码:711 / 719
页数:9
相关论文
共 38 条
  • [1] Visual acuity and defocus curves with six multifocal intraocular lenses
    Gil, Miguel A.
    Varon, Consuelo
    Cardona, Genis
    Buil, Jose A.
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (02) : 393 - 401
  • [2] Visual acuity and defocus curves with six multifocal intraocular lenses
    Miguel A. Gil
    Consuelo Varón
    Genis Cardona
    José A. Buil
    International Ophthalmology, 2020, 40 : 393 - 401
  • [3] Optimum design of the hybrid (diffractive/refractive) multifocal intraocular lenses implanted within human eye
    Al-Hamdani, Ali H.
    Rashid, Hayfa G.
    Hashim, Hussein T.
    KUWAIT JOURNAL OF SCIENCE, 2021, 48 (01) : 59 - 66
  • [4] DISTANCE VISUAL-ACUITY WITH DIFFRACTIVE MULTIFOCAL AND MONOFOCAL INTRAOCULAR LENSES
    WILLE, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (02): : 251 - 253
  • [5] Investigation of Pupillary Responses in Healthy Eyes and Eyes Implanted with Multifocal or Monofocal Intraocular Lenses
    Miyata, Kohei
    Kobayakawa, Shinichiro
    CURRENT EYE RESEARCH, 2025,
  • [6] Agreement between Two Devices for Measuring Pupil Diameter in Patients Implanted with Multifocal Intraocular Lenses
    Fernandez, Joaquin
    Burguera, Noemi
    Rocha-de-Lossada, Carlos
    Rodriguez-Calvo-de-Mora, Marina
    Rodriguez-Vallejo, Manuel
    VISION, 2023, 7 (02)
  • [7] Near visual acuity after implantation of monofocal versus multifocal intraocular lenses
    Dick, HB
    Krist, R
    Schwenn, O
    Pfeiffer, N
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (06) : 406 - 411
  • [8] Improvements in visual function early after cataract surgery in eyes implanted with multifocal intraocular lenses
    Hayashi, Ken
    Yoshida, Motoaki
    Manabe, Shin-ichi
    Hirata, Akira
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2025, 69 (01) : 32 - 42
  • [9] Aberrometry in Patients Implanted With Accommodative Intraocular Lenses
    Perez-Merino, Pablo
    Birkenfeld, Judith
    Dorronsoro, Carlos
    Ortiz, Sergio
    Duran, Sonia
    Jimenez-Alfaro, Ignacio
    Marcos, Susana
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (05) : 1077 - 1089
  • [10] Visual Acuity and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses
    Trueb, Peter R.
    Albach, Caroline
    Montes-Mico, Robert
    Ferrer-Blasco, Teresa
    OPHTHALMOLOGY, 2009, 116 (05) : 890 - 895