Piezoelectric scanning mirrors for endoscopic optical coherence tomography

被引:44
作者
Gilchrist, Kristin H. [1 ]
McNabb, Ryan P. [2 ,3 ]
Izatt, Joseph A. [2 ,3 ]
Grego, Sonia [1 ]
机构
[1] RTI Int, Ctr Mat & Elect Technol, Res Triangle Pk, NC 27709 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[3] Duke Univ, Fitzpatrick Inst Photon, Durham, NC 27708 USA
关键词
HIGH-SPEED; SWEPT SOURCE; CATHETER; PZT; INTERFEROMETER; MICROSCOPY; ACTUATORS; DRIVEN;
D O I
10.1088/0960-1317/19/9/095012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel piezoelectric scanning mirror design for endoscopic optical coherence tomography (OCT) is presented. OCT is an interferometric technique providing microscopic tomographic sectioning of biological samples with mm-range penetration capability in tissue and is suited for integration with endoscopes using fiber-based light delivery to the sample. The piezoelectric scanning mirror was designed to provide wide-range rapid forwarding-looking scanning of the optical beam at the distal end of a compact catheter. The optical scanner provides a large ratio of mirror aperture to device size with rectangular mirror sizes ranging from 600 mu m x 840 mu m to 840 mu m x 1600 mu m. Static angular displacements up to +/-7 degrees (mechanical angle) were demonstrated and resonance frequencies of hundreds of Hz (and up to 1-2 kHz) were measured, depending on the mirror size. The imaging capability of the piezoelectric scanner was demonstrated using a bench-top spectrometer-based Fourier-domain OCT system.
引用
收藏
页数:11
相关论文
共 27 条
[1]   Forward-imaging instruments for optical coherence tomography [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Tearney, GJ ;
Fujimoto, JG ;
Brezinski, ME .
OPTICS LETTERS, 1997, 22 (21) :1618-1620
[2]   Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ .
OPTICS LETTERS, 1999, 24 (08) :531-533
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[5]   Endoscopic applications of optical coherence tomography [J].
Feldchtein, FI ;
Gelikonov, GV ;
Gelikonov, VM ;
Kuranov, RV ;
Sergeev, AM ;
Gladkova, ND ;
Shakhov, AV ;
Shakhova, NM ;
Snopova, LB ;
Terent'eva, AB ;
Zagainova, EV ;
Chumakov, YP ;
Kuznetzova, IA .
OPTICS EXPRESS, 1998, 3 (06) :257-270
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Optical coherence tomography and microscopy in gastrointestinal tissues [J].
Izatt, JA ;
Kulkarni, MD ;
Wang, HW ;
Kobayashi, K ;
Sivak, MV .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) :1017-1028
[8]   Two-axis magnetically-driven MEMS scanning catheter for endoscopic high-speed optical coherence tomography [J].
Kim, Ki Hean ;
Park, B. Hyle ;
Maguluri, Gopi N. ;
Lee, Tom W. ;
Rogomentich, Fran J. ;
Bancu, Mirela G. ;
Bouma, Brett E. ;
de Boer, Johannes F. ;
Bernstein, Jonathan J. .
OPTICS EXPRESS, 2007, 15 (26) :18130-18140
[9]   Fabrication of optical micro scanner driven by PZT actuators [J].
Kobayashi, T ;
Tsaur, J ;
Maeda, R .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (9B) :7078-7082
[10]   Fast 3D in vivo swept-source optical coherence tomography using a two-axis MEMS scanning micromirror [J].
Kumar, Karthik ;
Condit, Jonathan C. ;
McElroy, Austin ;
Kemp, Nate J. ;
Hoshino, Kazunori ;
Milner, Thomas E. ;
Zhang, Xiaojing .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2008, 10 (04)