Performance evaluation of a lossy transmission lines based diode detector at cryogenic temperature

被引:1
|
作者
Villa, E. [1 ]
Aja, B. [1 ]
de la Fuente, L. [1 ]
Artal, E. [1 ]
机构
[1] Univ Cantabria, Dept Ingn Comunicac, Plaza Ciencia S-N, E-39005 Santander, Spain
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 01期
关键词
SCHOTTKY; DESIGN;
D O I
10.1063/1.4939730
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work is focused on the design, fabrication, and performance analysis of a square-law Schottky diode detector based on lossy transmission lines working under cryogenic temperature (15 K). The design analysis of a microwave detector, based on a planar gallium-arsenide low effective Schottky barrier height diode, is reported, which is aimed for achieving large input return loss as well as flat sensitivity versus frequency. The designed circuit demonstrates good sensitivity, as well as a good return loss in a wide bandwidth at Ka-band, at both room (300 K) and cryogenic (15 K) temperatures. A good sensitivity of 1000 mV/mW and input return loss better than 12 dB have been achieved when it works as a zero-bias Schottky diode detector at room temperature, increasing the sensitivity up to a minimum of 2200 mV/mW, with the need of a DC bias current, at cryogenic temperature. (C) 2016 AIP Publishing LLC.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Diode Array Transmission Detector Systems Evaluation
    Hoffman, D.
    Dyer, B.
    Nair, C. Kumaran
    Katuri, Y.
    Rong, Y.
    Benedict, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3538 - 3538
  • [2] Influence of a lossy ground on the lightning performance of overhead transmission lines
    Alipio, Rafael
    De Conti, Alberto
    Duarte, Naiara
    Rachidi, Farhad
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 214
  • [3] Broadband calibration of long lossy microwave transmission lines at cryogenic temperatures using nichrome films
    Stutzman, ML
    Lee, M
    Bradley, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (12): : 4596 - 4599
  • [4] Sensitivity Analysis of Lossy Transmission Lines based on the Passive Method of Characteristics
    Beygi, Amir
    Dounavis, Anestis
    ELECTRICAL PERFORMANCE OF ELECTRONIC PACKAGING AND SYSTEMS, 2009, : 171 - 174
  • [5] Passive Macromodeling of Lossy Multiconductor Transmission Lines Based on the Method of Characteristics
    Dounavis, Anestis
    Pothiwala, Vrajesh A.
    Beygi, Amir
    IEEE TRANSACTIONS ON ADVANCED PACKAGING, 2009, 32 (01): : 184 - 198
  • [6] Wavelet-based waveform relaxation simulation of lossy transmission lines
    Leung, WH
    Chang, FY
    ISCAS 96: 1996 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS - CIRCUITS AND SYSTEMS CONNECTING THE WORLD, VOL 4, 1996, : 739 - 742
  • [7] Performance of high-power diode lasers operated at cryogenic temperature
    Zhang, Pu
    Wang, Mingpei
    Nie, Zhiqiang
    Yang, Wuhao
    SEMICONDUCTOR LASERS AND APPLICATIONS IX, 2019, 11182
  • [8] A systematic evaluation of the error detection abilities of a new diode transmission detector
    Sarkar, Vikren
    Paxton, Adam
    Kunz, Jeremy
    Szegedi, Martin
    Nelson, Geoff
    Rassiah-Szegedi, Prema
    Zhao, Hui
    Huang, Y. Jessica
    Su, Frances
    Salter, Bill J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 122 - 132
  • [9] A Systematic Evaluation of the Error Detection Abilities of a Novel Diode Transmission Detector
    Sarkar, V.
    Paxton, A.
    Kunz, J.
    Szegedi, M.
    Nelson, G.
    Su, F.
    Huang, Y.
    Zhao, H.
    Rassiah-Szegedi, P.
    Salter, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E176 - E176
  • [10] Relaxation-based transient analysis of lossy coupled transmission lines circuits using delay evaluation technique
    Watanabe, T
    Kamo, A
    Asai, H
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 1998, E81A (06): : 1055 - 1062