Atrioventricular Synchronous Pacing Using a Leadless Ventricular Pacemaker Results From the MARVEL 2 Study

被引:168
作者
Steinwender, Clemens [1 ,2 ]
Khelae, Surinder Kaur [3 ]
Garweg, Christophe [4 ]
Chan, Joseph Yat Sun [5 ]
Ritter, Philippe [6 ]
Johansen, Jens Brock [7 ]
Sagi, Venkata [8 ]
Epstein, Laurence M. [9 ]
Piccini, Jonathan P. [10 ,11 ]
Pascual, Mario [12 ]
Mont, Lluis [13 ]
Sheldon, Todd [14 ]
Splett, Vincent [14 ]
Stromberg, Kurt [14 ]
Wood, Nicole [14 ]
Chinitz, Larry [15 ]
机构
[1] Kepler Univ Hosp, Dept Cardiol, Linz, Austria
[2] Paracelsus Med Univ Salzburg, Dept Cardiol, Salzburg, Austria
[3] Inst Jantung Negara, Dept Electrophysiol, Kuala Lumpur, Malaysia
[4] Univ Hosp Leuven, Dept Cardiovasc Sci, Dept Cardiol, Leuven, Belgium
[5] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Hong Kong, Peoples R China
[6] CHU Bordeaux, Dept Electrophysiol & Cardiac Stimulat, Hop Haut Leveque, Pessac, France
[7] Odense Univ Hosp, Dept Cardiol, Odense, Denmark
[8] Baptist Med Ctr, Jacksonville, FL USA
[9] North Shore Univ Hosp, Dept Electrophysiol, New York, NY USA
[10] Duke Univ, Div Cardiol, Med Ctr, Durham, NC USA
[11] Duke Clin Res Inst, Durham, NC USA
[12] Baptist Hosp Miami, Miami Cardiac & Vasc Inst, Miami, FL USA
[13] Univ Barcelona, Hosp Clin, Inst Clin Cardiovasc ICCV, Barcelona, Spain
[14] Medtronic Inc, Mounds View, MN USA
[15] NYU, Leon H Charney Div Cardiol, Langone Med Ctr, New York, NY USA
关键词
atrioventricular synchrony; AV block; leadless pacemaker; TERM-FOLLOW-UP; ATRIAL;
D O I
10.1016/j.jacep.2019.10.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study reports on the performance of a leadless ventricular pacemaker with automated, enhanced accelerometer-based algorithms that provide atrioventricular (AV) synchronous pacing. BACKGROUND Despite many advantages, leadless pacemakers are currently only capable of single-chamber ventricular pacing. METHODS The prospective MARVEL 2 (Micra Atrial tRacking using a Ventricular accELerometer 2) study assessed the performance of an automated, enhanced accelerometer-based algorithm downloaded to the Micra leadless pacemaker for up to 5 h in patients with AV block. The primary efficacy objective was to demonstrate the superiority of the algorithm to provide AV synchronous (VDD) pacing versus VVI-50 pacing in patients with sinus rhythm and complete AV block. The primary safety objective was to demonstrate that the algorithm did not result in pauses or heart rates of >100 beats/min. RESULTS Overall, 75 patients from 12 centers were enrolled; an accelerometer-based algorithm was downloaded to their leadless pacemakers. Among the 40 patients with sinus rhythm and complete AV block included in the primary efficacy objective analysis, the proportion of patients with >= 70% AV synchrony at rest was significantly greater with VDD pacing than with VVI pacing (95% vs. 0%; p < 0.001). The mean percentage of AV synchrony increased from 26.8% (median: 26.9%) during WI pacing to 89.2% (median: 94.3%) during VDD pacing. There were no pauses or episodes of oversensing-induced tachycardia reported during VDD pacing in all 75 patients. CONCLUSIONS Accelerometer-based atrial sensing with an automated, enhanced algorithm significantly improved AV synchrony in patients with sinus rhythm and AV block who were implanted with a leadless ventricular pacemaker. (C) 2020 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:94 / 106
页数:13
相关论文
共 14 条
[11]  
Nielsen JC, 1998, CIRCULATION, V97, P987
[12]   A Leadless Intracardiac Transcatheter Pacing System [J].
Reynolds, Dwight ;
Duray, Gabor Z. ;
Omar, Razali ;
Soejima, Kyoko ;
Neuzil, Petr ;
Zhang, Shu ;
Narasimhan, Calambur ;
Steinwender, Clemens ;
Brugada, Josep ;
Lloyd, Michael ;
Roberts, Paul R. ;
Sagi, Venkata ;
Hummel, John ;
Bongiorni, Maria Grazia ;
Knops, Reinoud E. ;
Ellis, Christopher R. ;
Gornick, Charles C. ;
Bernabei, Matthew A. ;
Laager, Verla ;
Stromberg, Kurt ;
Williams, Eric R. ;
Hudnall, J. Harrison ;
Ritter, Philippe .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (06) :533-541
[13]   CARDIOVASCULAR HEMODYNAMIC FUNCTIONS IN COMPLETE HEART BLOCK AND THE EFFECT OF ISOPROPYLNOREPINEPHRINE [J].
STACK, MF ;
RADER, B ;
SOBOL, BJ ;
FARBER, SJ ;
EICHNA, LW .
CIRCULATION, 1958, 17 (04) :526-536
[14]   Incidence and predictors of short- and long-term complications in pacemaker therapy: The FOLLOWPACE study [J].
Udo, Erik O. ;
Zuithoff, Nicolaas P. A. ;
van Hemel, Norbert M. ;
de Cock, Carel C. ;
Hendriks, Thijs ;
Doevendans, Pieter A. ;
Moons, Karel G. M. .
HEART RHYTHM, 2012, 9 (05) :728-735