Atrioventricular Synchronous Pacing Using a Leadless Ventricular Pacemaker Results From the MARVEL 2 Study

被引:168
作者
Steinwender, Clemens [1 ,2 ]
Khelae, Surinder Kaur [3 ]
Garweg, Christophe [4 ]
Chan, Joseph Yat Sun [5 ]
Ritter, Philippe [6 ]
Johansen, Jens Brock [7 ]
Sagi, Venkata [8 ]
Epstein, Laurence M. [9 ]
Piccini, Jonathan P. [10 ,11 ]
Pascual, Mario [12 ]
Mont, Lluis [13 ]
Sheldon, Todd [14 ]
Splett, Vincent [14 ]
Stromberg, Kurt [14 ]
Wood, Nicole [14 ]
Chinitz, Larry [15 ]
机构
[1] Kepler Univ Hosp, Dept Cardiol, Linz, Austria
[2] Paracelsus Med Univ Salzburg, Dept Cardiol, Salzburg, Austria
[3] Inst Jantung Negara, Dept Electrophysiol, Kuala Lumpur, Malaysia
[4] Univ Hosp Leuven, Dept Cardiovasc Sci, Dept Cardiol, Leuven, Belgium
[5] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Hong Kong, Peoples R China
[6] CHU Bordeaux, Dept Electrophysiol & Cardiac Stimulat, Hop Haut Leveque, Pessac, France
[7] Odense Univ Hosp, Dept Cardiol, Odense, Denmark
[8] Baptist Med Ctr, Jacksonville, FL USA
[9] North Shore Univ Hosp, Dept Electrophysiol, New York, NY USA
[10] Duke Univ, Div Cardiol, Med Ctr, Durham, NC USA
[11] Duke Clin Res Inst, Durham, NC USA
[12] Baptist Hosp Miami, Miami Cardiac & Vasc Inst, Miami, FL USA
[13] Univ Barcelona, Hosp Clin, Inst Clin Cardiovasc ICCV, Barcelona, Spain
[14] Medtronic Inc, Mounds View, MN USA
[15] NYU, Leon H Charney Div Cardiol, Langone Med Ctr, New York, NY USA
关键词
atrioventricular synchrony; AV block; leadless pacemaker; TERM-FOLLOW-UP; ATRIAL;
D O I
10.1016/j.jacep.2019.10.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study reports on the performance of a leadless ventricular pacemaker with automated, enhanced accelerometer-based algorithms that provide atrioventricular (AV) synchronous pacing. BACKGROUND Despite many advantages, leadless pacemakers are currently only capable of single-chamber ventricular pacing. METHODS The prospective MARVEL 2 (Micra Atrial tRacking using a Ventricular accELerometer 2) study assessed the performance of an automated, enhanced accelerometer-based algorithm downloaded to the Micra leadless pacemaker for up to 5 h in patients with AV block. The primary efficacy objective was to demonstrate the superiority of the algorithm to provide AV synchronous (VDD) pacing versus VVI-50 pacing in patients with sinus rhythm and complete AV block. The primary safety objective was to demonstrate that the algorithm did not result in pauses or heart rates of >100 beats/min. RESULTS Overall, 75 patients from 12 centers were enrolled; an accelerometer-based algorithm was downloaded to their leadless pacemakers. Among the 40 patients with sinus rhythm and complete AV block included in the primary efficacy objective analysis, the proportion of patients with >= 70% AV synchrony at rest was significantly greater with VDD pacing than with VVI pacing (95% vs. 0%; p < 0.001). The mean percentage of AV synchrony increased from 26.8% (median: 26.9%) during WI pacing to 89.2% (median: 94.3%) during VDD pacing. There were no pauses or episodes of oversensing-induced tachycardia reported during VDD pacing in all 75 patients. CONCLUSIONS Accelerometer-based atrial sensing with an automated, enhanced algorithm significantly improved AV synchrony in patients with sinus rhythm and AV block who were implanted with a leadless ventricular pacemaker. (C) 2020 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:94 / 106
页数:13
相关论文
共 14 条
[1]   ITALIAN MULTICENTER STUDY ON A SINGLE LEAD VDD PACING SYSTEM USING A NARROW ATRIAL DIPOLE SPACING [J].
ANTONIOLI, GE ;
ANSANI, L ;
BARBIERI, D ;
GUARDIGLI, G ;
PERCOCO, GF ;
TOSELLI, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1890-1893
[2]   MAINTENANCE OF EXERCISE STROKE VOLUME DURING VENTRICULAR VERSUS ATRIAL SYNCHRONOUS PACING - ROLE OF CONTRACTILITY [J].
AUSUBEL, K ;
STEINGART, RM ;
SHIMSHI, M ;
KLEMENTOWICZ, P ;
FURMAN, S .
CIRCULATION, 1985, 72 (05) :1037-1043
[3]   SENSOR-TRIGGERED, RATE-VARIABLE CARDIAC PACING - CURRENT TECHNOLOGIES AND CLINICAL IMPLICATIONS [J].
BENDITT, DG ;
MILSTEIN, S ;
BUETIKOFER, J ;
GORNICK, CC ;
MIANULLI, M ;
FETTER, J .
ANNALS OF INTERNAL MEDICINE, 1987, 107 (05) :714-724
[4]   Accelerometer-based atrioventricular synchronous pacing with a ventricular leadless pacemaker: Results from the Micra atrioventricular feasibility studies [J].
Chinitz, Larry ;
Ritter, Philippe ;
Khelae, Surinder Kaur ;
Iacopino, Saverio ;
Garweg, Christophe ;
Grazia-Bongiorni, Maria ;
Neuzil, Petr ;
Johansen, Jens Brock ;
Mont, Lluis ;
Gonzalez, Efrain ;
Sagi, Venkata ;
Duray, Gabor Z. ;
Clementy, Nicolas ;
Sheldon, Todd ;
Splett, Vincent ;
Stromberg, Kurt ;
Wood, Nicole ;
Steinwender, Clemens .
HEART RHYTHM, 2018, 15 (09) :1363-1371
[5]   Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing Study [J].
Duray, Gabor Z. ;
Ritter, Philippe ;
El-Chami, Mikhael ;
Narasimhan, Calambur ;
Omar, Razali ;
Tolosana, Jose M. ;
Zhang, Shu ;
Soejima, Kyoko ;
Steinwender, Clemens ;
Rapallini, Leonardo ;
Cicic, Aida ;
Fagan, Dedra H. ;
Liu, Shufeng ;
Reynolds, Dwight .
HEART RHYTHM, 2017, 14 (05) :702-709
[6]   Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control [J].
El-Chami, Mikhael F. ;
Al-Samadi, Faisal ;
Clementy, Nicolas ;
Garweg, Christophe ;
Luis Martinez-Sande, Jose ;
Piccini, Jonathan P. ;
Iacopino, Saverio ;
Lloyd, Michael ;
Vinolas Prat, Xavier ;
Jacobsen, Michael Dilou ;
Ritter, Philippe ;
Johansen, Jens Brock ;
Tondo, Claudio ;
Liu, Fang ;
Fagan, Dedra H. ;
Eakley, Alyssa K. ;
Roberts, Paul R. .
HEART RHYTHM, 2018, 15 (12) :1800-1807
[7]   LONG-TERM FOLLOW-UP OF PATIENTS WITH SINGLE-LEAD VDD STIMULATION [J].
FOLINO, AF ;
BUJA, G ;
RUZZA, L ;
NAVA, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :1854-1858
[8]   Behavior of leadless AV synchronous pacing during atrial arrhythmias and stability of the atrial signals over time-Results of the MARVEL Evolve subanalysis [J].
Garweg, Christophe ;
Splett, Vincent ;
Sheldon, Todd J. ;
Chinitz, Larry ;
Ritter, Philippe ;
Steinwender, Clemens ;
Lemme, Francesca ;
Willems, Rik .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (03) :381-387
[9]   Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009 Increasing Complexity of Patients and Procedures [J].
Greenspon, Arnold J. ;
Patel, Jasmine D. ;
Lau, Edmund ;
Ochoa, Jorge A. ;
Frisch, Daniel R. ;
Ho, Reginald T. ;
Pavri, Behzad B. ;
Kurtz, Steven M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (16) :1540-1545
[10]   Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing [J].
Lamas, GA ;
Orav, J ;
Stambler, BS ;
Ellenbogen, KA ;
Sgarbossa, EB ;
Huang, SKS ;
Marinchak, RA ;
Estes, NAM ;
Mitchell, GF ;
Lieberman, EH ;
Mangione, CM ;
Goldman, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (16) :1097-1104