Optical DNA Biosensor Based on Square-Planar Ethyl Piperidine Substituted Nickel(II) Salphen Complex for Dengue Virus Detection

被引:20
作者
Ariffin, Eda Yuhana [1 ]
Tan, Ling Ling [2 ]
Abd Karim, Nurul Huda [1 ]
Heng, Lee Yook [1 ,2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Sci & Technol, Sch Chem Sci & Food Technol, Bangi 43600, Selangor De, Malaysia
[2] Univ Kebangsaan Malaysia, Inst Environm & Dev LESTARI, Southeast Asia Disaster Prevent Res Initiat SEADP, Bangi 43600, Selangor De, Malaysia
关键词
dengue virus detection; nickel(II) salphen complex; optical DNA biosensor; porous silica nanospheres; reflectance measurement; synthetic DNA binder; ESCHERICHIA-COLI O157-H7; METAL-COMPLEXES; IMMOBILIZATION; INFECTION; HYBRIDIZATION; OPTIMIZATION; ELECTRODES; MEMBRANE; SEROTYPE; PROBE;
D O I
10.3390/s18041173
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective optical DNA biosensor was developed for dengue virus detection based on novel square-planar piperidine side chain-functionalized N,N'-bis-4-(hydroxysalicylidene)-phenylenediamine-nickel(II), which was able to intercalate via nucleobase stacking within DNA and be functionalized as an optical DNA hybridization marker. 3-Aminopropyltriethoxysilane (APTS)-modified porous silica nanospheres (PSiNs), was synthesized with a facile mini-emulsion method to act as a high capacity DNA carrier matrix. The Schiff base salphen complexes-labelled probe to target nucleic acid on the PSiNs renders a colour change of the DNA biosensor to a yellow background colour, which could be quantified via a reflectance transduction method. The reflectometric DNA biosensor demonstrated a wide linear response range to target DNA over the concentration range of 1.0 x 10(-16)-1.0 x 10(-10) M (R-2 = 0.9879) with an ultralow limit of detection (LOD) at 0.2 aM. The optical DNA biosensor response was stable and maintainable at 92.8% of its initial response for up to seven days of storage duration with a response time of 90 min. The reflectance DNA biosensor obtained promising recovery values of close to 100% for the detection of spiked synthetic dengue virus serotypes 2 (DENV-2) DNA concentration in non-invasive human samples, indicating the high accuracy of the proposed DNA analytical method for early diagnosis of all potential infectious diseases or pathological genotypes.
引用
收藏
页数:16
相关论文
共 33 条
  • [1] Effects of Metal Coordination Geometry on Stabilization of Human Telomeric Quadruplex DNA by Square-Planar and Square-Pyramidal Metal Complexes
    Arola-Arnal, Anna
    Benet-Buchholz, Jordi
    Neidle, Stephen
    Vilar, Ramon
    [J]. INORGANIC CHEMISTRY, 2008, 47 (24) : 11910 - 11919
  • [2] The Endosymbiotic Bacterium Wolbachia Induces Resistance to Dengue Virus in Aedes aegypti
    Bian, Guowu
    Xu, Yao
    Lu, Peng
    Xie, Yan
    Xi, Zhiyong
    [J]. PLOS PATHOGENS, 2010, 6 (04) : 1 - 10
  • [3] Electrochemical transduction of DNA hybridization at modified electrodes by using an electroactive pyridoacridone intercalator
    Bouffier, Laurent
    Wang, Bingquan Stuart
    Roget, Andre
    Livache, Thierry
    Demeunynck, Martine
    Mailley, Pascal
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (04) : 1163 - 1172
  • [4] Molecular Basis of Structure-Activity Relationships between Salphen Metal Complexes and Human Telomeric DNA Quadruplexes
    Campbell, Nancy H.
    Abd Karim, Nurul H.
    Parkinson, Gary N.
    Gunaratnam, Mekala
    Petrucci, Vanessa
    Todd, Alan K.
    Vilar, Ramon
    Neidle, Stephen
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 2012, 55 (01) : 209 - 222
  • [5] Castor K.J., 2014, THESIS
  • [6] Detection of serum neopterin for early assessment of dengue virus infection
    Chan, Cangel P. Y.
    Choi, Junet W. Y.
    Cao, Kai-Yuan
    Wang, Ming
    Gao, Yang
    Zhou, Duan-Hua
    Di, Biao
    Xu, Hui-Fang
    Leung, Man-Fai
    Bergmann, Andreas
    Lehmann, Matthias
    Nie, Yong-Mei
    Cautherley, George W. H.
    Fuchs, Dietmar
    Renneberg, Reinhard
    Zheng, Bo-Jian
    [J]. JOURNAL OF INFECTION, 2006, 53 (03) : 152 - 158
  • [7] Development of an electrochemical membrane-based nanobiosensor for ultrasensitive detection of dengue virus
    Cheng, Ming Soon
    Ho, Jia Shin
    Tan, Cheong Huat
    Wong, Jeslyn Pei Sze
    Ng, Lee Ching
    Toh, Chee-Seng
    [J]. ANALYTICA CHIMICA ACTA, 2012, 725 : 74 - 80
  • [8] Impedimetric DNA Biosensor Based on a Nanoporous Alumina Membrane for the Detection of the Specific Oligonucleotide Sequence of Dengue Virus
    Deng, Jiajia
    Toh, Chee-Seng
    [J]. SENSORS, 2013, 13 (06): : 7774 - 7785
  • [9] Quantitative measurements of ammonium, hydrogenophosphate and Cu(II) by diffuse reflectance spectrometry
    Ghauch, A
    Rima, J
    Charef, A
    Suptil, J
    Fachinger, C
    Martin-Bouyer, M
    [J]. TALANTA, 1999, 48 (02) : 385 - 392
  • [10] A highly selective colorimetric and turn-on fluorescent chemosensor based on 1-(2-pyridylazo)-2-naphthol for the detection of aluminium(III) ions
    Gupta, Vinod Kumar
    Shoora, Sudhir Kumar
    Kumawat, Lokesh Kumar
    Jain, Ajay Kumar
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 15 - 24