Artefact-free late gadolinium enhancement imaging in patients with implanted cardiac devices using amodified broadband sequence: current strategies and results froma real-world patient cohort

被引:31
作者
Hilbert, Sebastian [1 ]
Weber, Alexander [1 ]
Nehrke, Kay [2 ]
Boernert, Peter [2 ]
Schnackenburg, Bernhard [2 ]
Oebel, Sabrina [1 ]
Spampinato, Ricardo [3 ]
Rogge, Cathleen [1 ]
Richter, Sergio [1 ]
Hindricks, Gerhard [1 ]
Paetsch, Ingo [1 ]
Jahnke, Cosima [1 ]
机构
[1] HELIOS Heart Ctr Leipzig, Dept Electrophysiol, Leipzig, Germany
[2] Philips Res Labs, Hamburg, Germany
[3] HELIOS Heart Ctr Leipzig, Dept Cardiac Surg, Leipzig, Germany
来源
EUROPACE | 2018年 / 20卷 / 05期
关键词
Late gadolinium enhancement; Cardiac magnetic resonance; Implanted cardiac devices; Inversion RF pulse; MAGNETIC-RESONANCE; ABLATION;
D O I
10.1093/europace/eux016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac magnetic resonance (CMR) imaging in patients with implanted cardiac devices is often limited by device-related imaging artefacts. Limitations can potentially be overcome by employing a broadband late gadolinium enhancement (LGE)-CMR imaging technique. The purpose of this study was to investigate the relationship between implanted cardiac devices and the optimal frequency offset on broadband LGE-CMR imaging to increase the artefact-free visibility of myocardial segments. Methods and results A phantom study was performed to characterize magnetic field disturbances related to 15 different cardiac devices. This was complemented by B0 and B1(+)imaging of three different device types in four healthy volunteers. Findings were validated in 28 patients with an indication for arrhythmogenic substrate characterization before catheter ablation. In the phantom study, the placement of a PM, implantable cardioverter-defibrillator (ICD) or CRT-D generator led to a significant impairment of the radiofrequency field. B0 mapping in phantom and volunteers showed the highest off-resonance maximum with CRT-D systems with the maximum off-resonance significantly decreasing for ICD or PM systems, respectively. In all patients, with conventional LGE imaging 73.1% (61.5-92.3%) of LV segments were free of device-related artefacts, while with the broadband LGE technique, a significant increase of artefact-free segments was achieved [96.4% (85.7-100%); P = 0.00008]. Conclusion Using a modified broadband sequence for LGE imaging significantly increased the number of artefact-free myocardial segments thereby leading to improved diagnostic value of the CMR exam. Since the occurrence and extent of hyperintensity artefacts are closely related to the individual device, more studies are warranted to evaluate if the results can be extrapolated to other devices and manufacturers.
引用
收藏
页码:801 / 807
页数:7
相关论文
共 10 条
[1]   3D delayed-enhanced magnetic resonance sequences improve conducting channel delineation prior to ventricular tachycardia ablation [J].
Andreu, David ;
Ortiz-Perez, Jose T. ;
Fernandez-Armenta, Juan ;
Guiu, Esther ;
Acosta, Juan ;
Prat-Gonzalez, Susanna ;
De Caralt, Teresa M. ;
Perea, Rosario J. ;
Garrido, Cesar ;
Mont, Lluis ;
Brugada, Josep ;
Berruezo, Antonio .
EUROPACE, 2015, 17 (06) :938-945
[2]   Usefulness of contrast-enhanced cardiac magnetic resonance in identifying the ventricular arrhythmia substrate and the approach needed for ablation [J].
Andreu, David ;
Tomas Ortiz-Perez, Jose ;
Boussy, Tim ;
Fernandez-Armenta, Juan ;
de Caralt, Teresa M. ;
Perea, Rosario J. ;
Prat-Gonzalez, Susanna ;
Mont, Lluis ;
Brugada, Josep ;
Berruezo, Antonio .
EUROPEAN HEART JOURNAL, 2014, 35 (20) :1316-1326
[3]   Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[4]   The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction. [J].
Kim, RJ ;
Wu, E ;
Rafael, A ;
Chen, EL ;
Parker, MA ;
Simonetti, O ;
Klocke, FJ ;
Bonow, RO ;
Judd, RM .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (20) :1445-1453
[5]   A Prospective Evaluation of a Protocol for Magnetic Resonance Imaging of Patients With Implanted Cardiac Devices [J].
Nazarian, Saman ;
Hansford, Rozann ;
Roguin, Ariel ;
Goldsher, Dorith ;
Zviman, Menekhem M. ;
Lardo, Albert C. ;
Caffo, Brian S. ;
Frick, Kevin D. ;
Kraut, Michael A. ;
Kamel, Ihab R. ;
Calkins, Hugh ;
Berger, Ronald D. ;
Bluemke, David A. ;
Halperin, Henry R. .
ANNALS OF INTERNAL MEDICINE, 2011, 155 (07) :415-U39
[6]   Improved Late Gadolinium Enhancement MR Imaging for Patients with Implanted Cardiac Devices [J].
Rashid, Shams ;
Rapacchi, Stanislas ;
Vaseghi, Marmar ;
Tung, Roderick ;
Shivkumar, Kalyanam ;
Finn, J. Paul ;
Hu, Peng .
RADIOLOGY, 2014, 270 (01) :269-274
[7]   Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs [J].
Shinbane, Jerold S. ;
Colletti, Patrick M. ;
Shellock, Frank G. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
[8]   An improved MR imaging technique for the visualization of myocardial infarction [J].
Simonetti, OP ;
Kim, RJ ;
Fieno, DS ;
Hillenbrand, HB ;
Wu, E ;
Bundy, JM ;
Finn, JP ;
Judd, RM .
RADIOLOGY, 2001, 218 (01) :215-223
[9]   MRI and cardiac implantable electronic devices; current status and required safety conditions [J].
van der Graaf, A. W. M. ;
Bhagirath, P. ;
Gotte, M. J. W. .
NETHERLANDS HEART JOURNAL, 2014, 22 (06) :269-276
[10]   Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field [J].
Yarnykh, Vasily L. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) :192-200