Posterior cruciate ligament balancing in total knee arthroplasty: a numerical study with a dynamic force controlled knee model

被引:18
作者
Steinbruk, Arnd [1 ]
Woiczinski, Matthias [1 ]
Weber, Patrick [1 ]
Mueller, Peter Ernst [1 ]
Jansson, Volkmar [1 ]
Schroder, Christian [1 ]
机构
[1] LMU, Univ Hosp Munich, Dept Orthoped Surg Phys Med & Rehabil, D-81377 Munich, Germany
关键词
Finite element model; Ligament balancing; TKA; Knee kinematics; Posterior cruciate ligament; FINITE-ELEMENT-ANALYSIS; REPLACEMENT MECHANICS; ANTERIOR-POSTERIOR; SIMULATION; JOINT; WEAR; BIOMECHANICS; GEOMETRY; BEHAVIOR; DRAWER;
D O I
10.1186/1475-925X-13-91
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Adequate soft tissue balancing is a key factor for a successful result after total knee arthroplasty (TKA). Posterior cruciate ligament (PCL) is the primary restraint to posterior translation of the tibia after cruciate retaining TKA and is also responsible for the amount of joint compression. However, it is complex to quantify the amount of ligament release with its effects on load bearing and kinematics in TKA and limited both in vivo and in vitro. The goal of this study was to create a dynamic and deformable finite element model of a full leg and analyze a stepwise release of the PCL regarding knee kinematics, pressure distribution and ligament stresses. Methods: A dynamic finite element model was developed in Ansys V14.0 based on boundary conditions of an existing knee rig. A cruciate retraining knee prosthesis was virtually implanted. Ligament and muscle structures were simulated with modified spring elements. Linear elastic materials were defined for femoral component, inlay and patella cartilage. A restart algorithm was developed and implemented into the finite element simulation to hold the ground reaction force constant by adapting quadriceps force. After simulating the unreleased PCL model, two models were developed and calculated with the same boundary conditions with a 50% and 75% release of the PCL stiffness. Results: From the beginning of the simulation to approximately 35 degrees of flexion, tibia moves posterior related to the femur and with higher flexion anteriorly. Anterior translation of the tibia ranged from 5.8 mm for unreleased PCL to 3.7 mm for 75% PCL release (4.9 mm 50% release). A decrease of maximum von Mises equivalent stress on the inlay was given with PCL release, especially in higher flexion angles from 11.1 MPa for unreleased PCL to 8.9 MPa for 50% release of the PCL and 7.8 MPa for 75% release. Conclusions: Our study showed that dynamic FEM is an effective method for simulation of PCL balancing in knee arthroplasty. A tight PCL led in silico to more anterior tibia translation, a higher collateral ligament and inlay stress, while retropatellar pressure remained unchanged. Surgeons may take these results in vivo into account.
引用
收藏
页数:13
相关论文
共 36 条
[1]  
[Anonymous], 2011, ANS MECH US GUID AN
[2]   Clinical biomechanics of instability related to total knee arthroplasty [J].
Athwal, Kiron K. ;
Hunt, Nicola C. ;
Davies, Andrew J. ;
Deehan, David J. ;
Amis, Andrew A. .
CLINICAL BIOMECHANICS, 2014, 29 (02) :119-128
[3]   Dynamic finite element knee simulation for evaluation of knee replacement mechanics [J].
Baldwin, Mark A. ;
Clary, Chadd W. ;
Fitzpatrick, Clare K. ;
Deacy, James S. ;
Maletsky, Lorin P. ;
Rullkoetter, Paul J. .
JOURNAL OF BIOMECHANICS, 2012, 45 (03) :474-483
[4]   A three-dimensional dynamic finite element model of the prosthetic knee joint: simulation of joint laxity and kinematics [J].
Barink, M ;
van Kampen, A ;
Malefijt, MD ;
Verdonschot, N .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H6) :415-424
[5]   The insertion geometry of the posterolateral corner of the knee [J].
Brinkman, JM ;
Schwering, PJA ;
Blankevoort, L ;
Koolos, JG ;
Luites, J ;
Wymenga, AB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (10) :1364-1368
[6]   LIGAMENTOUS RESTRAINTS TO ANTERIOR-POSTERIOR DRAWER IN THE HUMAN KNEE - BIOMECHANICAL STUDY [J].
BUTLER, DL ;
NOYES, FR ;
GROOD, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (02) :259-270
[7]   The influence of total knee arthroplasty geometry on mid-flexion stability: An experimental and finite element study [J].
Clary, Chadd W. ;
Fitzpatrick, Clare K. ;
Maletsky, Lorin P. ;
Rullkoetter, Paul J. .
JOURNAL OF BIOMECHANICS, 2013, 46 (07) :1351-1357
[8]   Evaluation of a computational model used to predict the patellofemoral contact pressure distribution [J].
Elias, JJ ;
Wilson, DR ;
Adamson, R ;
Cosgarea, AJ .
JOURNAL OF BIOMECHANICS, 2004, 37 (03) :295-302
[9]   Friction and wear mechanisms in hip prosthesis:: Comparison of joint materials behaviour in several lubricants [J].
Gispert, MP ;
Serro, AP ;
Colaço, R ;
Saramago, B .
WEAR, 2006, 260 (1-2) :149-158
[10]   Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis [J].
Godest, AC ;
Beaugonin, M ;
Haug, E ;
Taylor, M ;
Gregson, PJ .
JOURNAL OF BIOMECHANICS, 2002, 35 (02) :267-275