Solid phase microextraction: Measurement of volatile organic compounds (VOCs) in Dhaka city air pollution

被引:21
作者
Hussam, A [1 ]
Alauddin, M
Khan, AH
Chowdhury, D
Bibi, H
Bhattacharjee, M
Sultana, S
机构
[1] Wagner Coll, Dept Chem, Staten Isl, NY 10301 USA
[2] George Mason Univ, Dept Chem, Fairfax, VA 22030 USA
[3] Univ Dhaka, Dept Chem, Dhaka 1000, Bangladesh
[4] Intron Technol Ctr, Dhaka 1216, Bangladesh
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2002年 / 37卷 / 07期
关键词
solid phase microextraction; volatile organic compounds; air pollution; Dhaka city;
D O I
10.1081/ESE-120005982
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A solid phase microextraction (SPME) technique was applied for the sampling of volatile organic compounds (VOCs) in ambient air polluted by two stroke autorickshaw engines and automobile exhausts in Dhaka city, Bangladesh. Analysis was carried out by capillary gas chromatography (GC) and GC-mass spectrometry (MS). The methodology was tested by insitu sampling of an aromatic hydrocarbon mixture gas standard with a precision of +/-5% and an average accuracy of 1-20%. The accuracy for total VOCs concentration measurement was about 7%. VOC's in ambient air were collected by exposing the SPME fiber at four locations in Dhaka city. The chromatograms showed signature similar to that of unburned gasoline (petrol) and weathered diesel containing more than 200 organic compounds; some of these compounds were positively identified. These are normal hydrocarbons pentane (n-C5H12) through nonacosane (n-C29H60), aromatic hydrocarbons: benzene, toluene, ethylbenzene, n-propylbenzene, n-butylbenzene, 1,3,5-trimethylbenzene, xylenes, and 1-isocyanato-3-methoxybenzene. Two samples collected near an autorickshaw station contained 783 000 and 1 479 000 mug/m(3) of VOCs. In particular, the concentration of toluene was 50-100 times higher than the threshold limiting value of 2000 mug/m(3). Two other samples collected on street median showed 135 000 mug/m(3) and 180 000 mug/m(3) of total VOCs. The method detection limit of the technique for most semi-volatile organic compounds was I mug/m(3).
引用
收藏
页码:1223 / 1239
页数:17
相关论文
共 19 条
[1]  
[Anonymous], 1993, INT RISK INF SYST IR
[2]   Design and validation of portable SPME devices for rapid field air sampling and diffusion based calibration [J].
Augusto, F ;
Koziel, J ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :481-486
[3]  
BASSOW H, 1976, AIR POLLUTION CHEM E, P59
[4]  
BUTLER JD, 1979, AIR POLLUTION CHEM
[5]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[6]   Determination of benzene, toluene and xylene in ambient air of Calcutta for three years during winter [J].
Chattopadhyay, G ;
Samanta, G ;
Chatterjee, S ;
Chakraborti, D .
ENVIRONMENTAL TECHNOLOGY, 1997, 18 (02) :211-218
[7]   SULFUR-HEXAFLUORIDE AS A SURROGATE FOR VOLATILIZATION OF ORGANICS FROM INDOOR WATER USES [J].
GIARDINO, NJ ;
ANDELMAN, JB ;
BORRAZZO, JE ;
DAVIDSON, CI .
JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (03) :278-280
[8]  
*GOV PEOPL REP BAN, STAT POCK BANGL 1999
[9]  
JIAN C, 2001, AIR POLLUTION MASS K
[10]  
Khaliquzzaman M., 1997, AECDAFDCH648