Pulmonary hyperpolarized noble gas MRI: Recent advances and perspectives in clinical application

被引:34
作者
Liu, Zaiyi [1 ,2 ]
Araki, Tetsuro [1 ]
Okajima, Yuka [1 ]
Albert, Mitchell [3 ]
Hatabu, Hiroto [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Dept Radiol, Ctr Pulm Funct Imaging,Med Sch, Boston, MA 02115 USA
[2] Guangdong Acad Med Sci, Guangdong Gen Hosp, Dept Radiol, Guangzhou, Guangdong, Peoples R China
[3] Lakehead Univ, Thunder Bay Reg Res Inst, Hyperpolarized Gas MRI Lab, Thunder Bay, ON P7B 5E1, Canada
关键词
Hyperpolarized noble gas; MRI; He-3; Xe-129; Lung ventilation image; APPARENT DIFFUSION-COEFFICIENT; AIR-FLOW OBSTRUCTION; INDUCED LUNG INJURY; HE-3; MR; VENTILATION DEFECTS; HEALTHY-VOLUNTEERS; QUANTITATIVE ASSESSMENT; COMPUTED-TOMOGRAPHY; PARTIAL-PRESSURE; ASTHMA;
D O I
10.1016/j.ejrad.2014.04.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The invention of hyperpolarized (HP) noble gas MRI using helium-3 (He-3) or xenon-129 (Xe-129) has provided a new method to evaluate lung function. Using HP 3He or 129Xe for inhalation into the lung air spaces as an MRI contrast agent significantly increases MR signal and makes pulmonary ventilation imaging feasible. This review focuses on important aspects of pulmonary HP noble gas MRI, including the following: (1) functional imaging types, (2) applications for major pulmonary diseases, (3) safety considerations, and (4) future directions. Although it is still challenging to use pulmonary HP noble gas MRI clinically, the technology offers promise for the investigation of the microstructure and function of the lungs. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1282 / 1291
页数:10
相关论文
共 91 条
[1]  
ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
[2]   Can Hyperpolarized Helium MRI add to radiation planning and follow-up in lung cancer? [J].
Allen, Aaron M. ;
Albert, Mitchell ;
Caglar, Hale B. ;
Zygmanski, Piotr ;
Soto, Ricardo ;
Killoran, Joseph ;
Sun, Yangping .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02) :169-183
[3]   Demonstration of the Heterogeneous Distribution of Asthma in the Lungs Using CT and Hyperpolarized Helium-3 MRI [J].
Aysola, Ravi ;
de Lange, Eduard E. ;
Castro, Mario ;
Altes, Talissa A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (06) :1379-1387
[4]   Hyperpolarized 3He MR for Sensitive Imaging of Ventilation Function and Treatment Efficiency in Young Cystic Fibrosis Patients with Normal Lung Function [J].
Bannier, Elise ;
Cieslar, Katarzyna ;
Mosbah, Karim ;
Aubert, Francoise ;
Duboeuf, Francois ;
Salhi, Zahir ;
Gaillard, Sophie ;
Berthezene, Yves ;
Cremillieux, Yannick ;
Reix, Philippe .
RADIOLOGY, 2010, 255 (01) :225-232
[5]   A fast and highly automated approach to myocardial motion analysis using phase contrast magnetic resonance imaging [J].
Bergvall, E ;
Cain, P ;
Arheden, H ;
Sparr, G .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) :652-661
[6]  
Biederer J, 2012, INSIGHTS IMAGING, V3, P373, DOI 10.1007/s13244-011-0142-z
[7]   Clinical aspects of the apparent diffusion coefficient in 3He MRI:: Results in healthy volunteers and patients after lung transplantation [J].
Bink, Andrea ;
Hanisch, Gorden ;
Karg, Andrea ;
Vogel, Annette ;
Katsaros, Konstantinos ;
Mayer, Eckhard ;
Gast, Klaus K. ;
Kauczor, Hans-Ulrich .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) :1152-1158
[8]   MR grid-tagging using hyperpolarized helium-3 for regional quantitative assessment of pulmonary biomechanics and ventilation [J].
Cai, J. ;
Altes, T. A. ;
Miller, G. W. ;
Sheng, K. ;
Read, P. W. ;
Mata, J. F. ;
Zhong, X. ;
Cates, G. D., Jr. ;
de Lange, E. E. ;
Mugler, J. P., III ;
Brookeman, J. R. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) :373-380
[9]   Direct measurement of lung motion using hyperpolarized helium-3 MR tagging [J].
Cai, Jing ;
Miller, G. Wilson ;
Altes, Talissa A. ;
Read, Paul W. ;
Benedict, Stanley H. ;
De lange, Eduard E. ;
Cates, Gordon D. ;
Brookeman, James R. ;
Mugler, John P., III ;
Sheng, Ke .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03) :650-653
[10]   HELICAL TOMOTHERAPY PLANNING FOR LUNG CANCER BASED ON VENTILATION MAGNETIC RESONANCE IMAGING [J].
Cai, Jing ;
McLawhorn, Robert ;
Altes, Tallisa A. ;
de Lange, Eduard ;
Read, Paul W. ;
Larner, James M. ;
Benedict, Stanley H. ;
Sheng, Ke .
MEDICAL DOSIMETRY, 2011, 36 (04) :389-396