Infections of implantable cardioverter-defibrillators:: frequency, predisposing factors and clinical significance

被引:14
作者
Gil, P.
Guerrero, M. L. Fernandez
Bayona, J. F.
Rubio, J. M.
de Gorgolas, M.
Granizo, J. J.
Farre, J.
机构
[1] Univ Autonoma Madrid, Fdn Jimenez Diaz, Div Infect Dis, E-28040 Madrid, Spain
[2] Univ Autonoma Madrid, Fdn Jimenez Diaz, Dept Cardiol, E-28040 Madrid, Spain
[3] Univ Autonoma Madrid, Fdn Jimenez Diaz, Dept Epidemiol, E-28040 Madrid, Spain
关键词
implantable cardioverter defibrillator; infection; management; pacemaker; risk-factors; surgical technique;
D O I
10.1111/j.1469-0691.2006.01434.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The prognosis for patients with ventricular arrhythmias has improved dramatically with the aid of implantable cardioverter-defibrillators (ICDs). Although infection is a serious complication that frequently causes dysfunction and loss of ICDs, the frequency, predisposing risk-factors, and clinical and microbiological features are only partially understood. This study describes a retrospective review of 423 procedures in 278 patients with ICD primary implants and replacements performed at a tertiary-care hospital. Generators were placed in either a pectoral (68%) or abdominal (32%) site, and electrodes were placed transvenously in 97% of the patients. Most (95%) interventions were performed in a one-stage procedure. Infection developed with ten (2.4%) implanted devices. Four cases occurred within 30 days of surgery ('early infections') and six occurred > 1 month after surgery ('late infections'). In univariate analysis, factors associated with the development of an early infection were: two-stage surgery, a sub-costal approach, and abdominal generator placement. In patients with late infections, a significant association was found with trauma or decubitus ulcer in the generator area. Infection presented with local signs without systemic complications. Seven of the ten patients required complete removal of the system.
引用
收藏
页码:533 / 537
页数:5
相关论文
共 14 条
[1]   INFECTIONS INVOLVING IMPLANTED CARDIOVERTER DEFIBRILLATOR DEVICES [J].
BAKKER, PFA ;
HAUER, RNW ;
WEVER, EFD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (04) :654-658
[2]   Diagnosis and management of infections involving implantable electrophysiologic cardiac devices [J].
Chua, JD ;
Wilkoff, BL ;
Lee, I ;
Juratli, N ;
Longworth, DL ;
Gordon, SM .
ANNALS OF INTERNAL MEDICINE, 2000, 133 (08) :604-608
[3]   Lead- and device-related complications in the Antiarrhythmics versus implantable defibrillators trial [J].
Kron, J ;
Herre, J ;
Renfroe, EG ;
Rizo-Patron, C ;
Raitt, M ;
Halperin, B ;
Gold, M ;
Goldner, B ;
Wathen, M ;
Wilkoff, B ;
Olarte, A ;
Yao, Q .
AMERICAN HEART JOURNAL, 2001, 141 (01) :92-98
[4]   Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: Epidemiology, infection control, and management [J].
Lai, KK ;
Fontecchio, SA .
CLINICAL INFECTIOUS DISEASES, 1998, 27 (02) :265-269
[5]  
McAnulty J, 1997, NEW ENGL J MED, V337, P1576
[6]   Long-term infection rates associated with the pectoral versus abdominal approach to cardioverter-defibrillator implants [J].
Mela, T ;
McGovern, BA ;
Garan, H ;
Vlahakes, GJ ;
Torchiana, DF ;
Ruskin, J ;
Galvin, JM .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (07) :750-753
[7]  
Molina JE, 1997, ANN THORAC SURG, V63, P504
[8]   Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia [J].
Moss, AJ ;
Hall, WJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Klein, H ;
Levine, JH ;
Saksena, S ;
Waldo, AL ;
Wilber, D ;
Brown, MW ;
Heo, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (26) :1933-1940
[9]   Implantable cardiac defibrillators [J].
Peters, RW ;
Gold, MR .
MEDICAL CLINICS OF NORTH AMERICA, 2001, 85 (02) :343-+
[10]   POSTOPERATIVE LEAD-RELATED COMPLICATIONS IN PATIENTS WITH NONTHORACOTOMY DEFIBRILLATION LEAD SYSTEMS [J].
SCHWARTZMAN, D ;
NALLAMOTHU, N ;
CALLANS, DJ ;
PREMINGER, MW ;
GOTTLIEB, CD ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) :776-786