Image distortion correction in EPI: Comparison of field mapping with point spread function mapping

被引:201
|
作者
Zeng, HR
Constable, RT
机构
[1] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
[2] Yale Univ, Sch Med, Dept Neurosurg, New Haven, CT 06520 USA
关键词
echo-planar imaging; point spread function; field mapping; geometric distortion; rapid imaging;
D O I
10.1002/mrm.10200
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar imaging (EPI) can provide rapid imaging by acquiring a complete k-space data set in a single acquisition. However, this approach suffers from distortion effects in geometry and intensity, resulting in poor image quality. The distortions, caused primarily by field inhomogeneities, lead to intensity loss and voxel shifts, the latter of which are particularly severe in the phase-encode direction. Two promising approaches to correct the distortion in EPI are field mapping and point spread function (PSF) mapping. The field mapping method measures the field distortions and translates these into voxel shifts, which can be used to assign image intensities to the correct voxel locations. The PSF approach uses acquisitions with additional phase-encoding gradients applied in the x, y, and/or z directions to map the 1D, 2D, or 3D PSF of each voxel. These PSFs encode the spatial information about the distortion and the overall distribution of intensities from a single voxel. The measured image is the convolution of the undistorted density and the PSF. Measuring the PSF allows the distortion in geometry and intensity to be corrected. This work compares the efficacy of these methods with equal time allowed for field mapping and PSF mapping. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 50 条
  • [21] Image restoration with an a priori estimation of the point spread function
    Protasov, KT
    Belov, VV
    Molchunov, NV
    SIXTH INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS, 1999, 3983 : 160 - 169
  • [22] Comparison of point spread models for underwater image restoration
    Chen, Yuzhang
    Xia, Min
    Li, Wei
    Zhang, Xiaohui
    Yang, Kecheng
    OPTIK, 2012, 123 (09): : 753 - 757
  • [23] Distorted point spread function and image reconstruction for ghost imaging
    Li, Zijie
    Zhao, Qing
    Gong, Wenlin
    OPTICS AND LASERS IN ENGINEERING, 2021, 139
  • [24] Conservation of energy between pupil and image for point spread function
    Shibuya, Masato
    Tanabe, Takao
    Toyoda, Mitsunori
    OPTIK, 2022, 249
  • [25] Skin dose mapping for non-uniform x-ray fields using a backscatter point spread function
    Vijayan, Sarath
    Xiong, Zhenyu
    Shankar, Alok
    Rudin, Stephen
    Bednarek, Daniel R.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [26] Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps
    Reber, PJ
    Wong, EC
    Buxton, RB
    Frank, LR
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) : 328 - 330
  • [27] Realization Method of Full-Field Point Spread Function
    Luo, Hongmei
    Cen, Zhaofeng
    Li, Xiaotong
    OPTICAL DESIGN AND TESTING V, 2012, 8557
  • [28] Improved Field-Mapping and Artifact Correction in Multispectral Imaging
    Quist, Brady
    Shi, Xinwei
    Weber, Hans
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 2022 - 2034
  • [29] Minimizing susceptibility-induced BOLD sensitivity loss in multi-band accelerated fMRI using point spread function mapping and gradient reversal
    In, Myung-Ho
    Kang, Daehun
    Jo, Hang Joon
    Yarach, Uten
    Meyer, Nolan K.
    Trzasko, Joshua D.
    Huston III, John
    Bernstein, Matt A.
    Shu, Yunhong
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02)
  • [30] Distortion correction in echo-planar imaging and quantitative T2* mapping
    Dierkes, T
    Neeb, H
    Shah, NJ
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 181 - 185