Enhanced sensitivity of piezoelectric pressure sensor with microstructured polydimethylsiloxane layer

被引:89
作者
Choi, Wook [1 ]
Lee, Junwoo [1 ]
Yoo, Yong Kyoung [1 ]
Kang, Sungchul [2 ]
Kim, Jinseok [2 ]
Lee, Jeong Hoon [1 ]
机构
[1] Kwangwoon Univ, Dept Elect Engn, Seoul 139701, South Korea
[2] KIST, Seoul 136791, South Korea
关键词
FILM; TRANSDUCTION; FINGER; RUBBER; TOUCH;
D O I
10.1063/1.4869816
中图分类号
O59 [应用物理学];
学科分类号
摘要
Highly sensitive detection tools that measure pressure and force are essential in palpation as well as real-time pressure monitoring in biomedical applications. So far, measurement has mainly been done by force sensing resistors and field effect transistor (FET) sensors for monitoring biological pressure and force sensing. We report a pressure sensor by the combination of a piezoelectric sensor layer integrated with a microstructured Polydimethylsiloxane (mu-PDMS) layer. We propose an enhanced sensing tool to be used for analyzing gentle touches without the external voltage source that is used in FET sensors, by incorporating a microstructured PDMS layer in a piezoelectric sensor. By measuring the directly induced electrical charge from the microstructure-enhanced piezoelectric signal, we observed a 3-fold increased sensitivity in a signal response. Both fast signal relaxation from force removal and wide dynamic range from 0.23 to 10 kPa illustrate the good feasibility of the thin film piezoelectric sensor for mimicking human skin. (C) 2014 AIP Publishing LLC. [http://dx.doi.org/10.1063/1.4869816]
引用
收藏
页数:4
相关论文
共 25 条
  • [1] 4 CHANNELS MEDIATE THE MECHANICAL ASPECTS OF TOUCH
    BOLANOWSKI, SJ
    GESCHEIDER, GA
    VERRILLO, RT
    CHECKOSKY, CM
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (05) : 1680 - 1694
  • [2] Highly sensitive polymer-based cantilever-sensors for DNA detection
    Calleja, M
    Nordström, M
    Alvarez, M
    Tamayo, J
    Lechuga, LM
    Boisen, A
    [J]. ULTRAMICROSCOPY, 2005, 105 (1-4) : 215 - 222
  • [3] Chun J., ADV FUNCT MAT
  • [4] Dargahi J., 2004, Sensor Review, V24, P74, DOI 10.1108/02602280410515851
  • [5] Mechanical force sensors using organic thin-film transistors -: art. no. 093708
    Darlinski, G
    Böttger, U
    Waser, R
    Klauk, H
    Halik, M
    Zschieschang, U
    Schmid, G
    Dehm, C
    [J]. JOURNAL OF APPLIED PHYSICS, 2005, 97 (09)
  • [6] Molecular basis of mechanosensory transduction
    Gillespie, PG
    Walker, RG
    [J]. NATURE, 2001, 413 (6852) : 194 - 202
  • [7] Elastic moduli of breast and prostate tissues under compression
    Krouskop, TA
    Wheeler, TM
    Kallel, F
    Garra, BS
    Hall, T
    [J]. ULTRASONIC IMAGING, 1998, 20 (04) : 260 - 274
  • [8] Polyimide membrane with ZnO piezoelectric thin film pressure transducers as a differential pressure liquid flow sensor
    Kuoni, A
    Holzherr, R
    Boillat, M
    de Rooij, NF
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (04) : S103 - S107
  • [9] Micromachined piezoelectric force sensors based on PZT thin films
    Lee, CK
    Itoh, T
    Suga, T
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (04) : 553 - 559
  • [10] Microstress relaxation effect of Pb(Zr0.52Ti0.48)O3 films with thicknesses for micro/nanopiezoelectric device
    Lee, Jeong Hoon
    Hwang, Kyo Seon
    Kim, Tae Song
    [J]. APPLIED PHYSICS LETTERS, 2010, 96 (09)