Design optimisation and characterisation of an amperometric glutamate oxidase-based composite biosensor for neurotransmitter L-glutamic acid

被引:11
作者
Bermingham, Kobi P. [1 ]
Doran, Michelle M. [1 ]
Bolger, Fiachra B. [1 ]
Lowry, John P. [1 ]
机构
[1] Maynooth Univ, Dept Chem, Neurochem Lab, Maynooth, Kildare, Ireland
基金
爱尔兰科学基金会;
关键词
Glutamate; Biosensor; Amperometry; Neurochemistry; Rat brain; CHARACTERIZATION IN-VITRO; MODIFIED POLY(PHENYLENEDIAMINE)-COATED ELECTRODES; CATALASE-BASED BIOSENSOR; NEUROCHEMICAL ANALYSIS; HYDROGEN-PEROXIDE; MICROELECTROCHEMICAL BIOSENSOR; VIVO CHARACTERIZATION; PT-IR; BRAIN; GLUCOSE;
D O I
10.1016/j.aca.2022.340205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polymer/enzyme composite biosensor for monitoring neurochemical glutamate was performance optimised in vitro for sensitivity, selectivity and stability. This first generation Pt/glutamate oxidase-based sensor displayed appropriate sensitivity (90.4 +/- 2.0 nA cm(-2) mu M-1). It also has ideal stability/biocompatibility with no significant decrease in response observed for repeated calibrations, exposure to electron beam sterilisation, or following storage at 4 degrees C either dry (28 days) or in ex-vivo rodent brain tissue (14 days). Potential non-glutamate contributing signals, generated by extracellular levels of the principal endogenous electroactive interferents, were typically <5% of the basal (10 mu M) glutamate response. Changes in molecular oxygen (the natural enzyme mediator) over the normal brain tissue range of 40-80 mu M had minimal effect on the glutamate signal for concentrations of 10 and 100 mu M (Mean KMO2 = 1.86 +/- 0.74 mu M, [O-2] (90%) = ca. 15 mu M). Additionally, a low mu M calculated limit of detection (0.44 +/- 0.05) and rapid response time (ca. 1.67 +/- 0.06 s), combined with no effect of pH and temperature changes over physiologically relevant ranges (7.2-7.6 and 34-40 degrees C respectively), collectively suggest that this composite biosensor should reliably detect L-glutamate when used for neurochemical monitoring. Preliminary experiments involving implantation in the striatum of freely moving rats demonstrated stable recording over several weeks, and reliable detection of physiological changes in glutamate in response to behavioural/neuronal activation (locomotor activity and restraint stress).
引用
收藏
页数:10
相关论文
共 64 条
  • [1] Characterisation of a Platinum-based Electrochemical Biosensor for Real-time Neurochemical Analysis of Choline
    Baker, Keeley L.
    Bolger, Fiachra B.
    Doran, Michelle M.
    Lowry, John P.
    [J]. ELECTROANALYSIS, 2019, 31 (01) : 129 - 136
  • [2] Development of a microelectrochemical biosensor for the real-time detection of choline
    Baker, Keeley L.
    Bolger, Fiachra B.
    Lowry, John P.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 412 - 420
  • [3] A microelectrochemical biosensor for real-time in vivo monitoring of brain extracellular choline
    Baker, Keeley L.
    Bolger, Fiachra B.
    Lowry, John P.
    [J]. ANALYST, 2015, 140 (11) : 3738 - 3745
  • [4] Glutamate, GABA and epilepsy
    Bradford, HF
    [J]. PROGRESS IN NEUROBIOLOGY, 1995, 47 (06) : 477 - 511
  • [5] L-tyrosine contributes to (+)-3,4-methylenedioxymethamphetamine-induced serotonin depletions
    Breier, JM
    Bankson, MG
    Yamamoto, BK
    [J]. JOURNAL OF NEUROSCIENCE, 2006, 26 (01) : 290 - 299
  • [6] Microelectrochemical sensors for in vivo brain analysis:: an investigation of procedures for modifying Pt electrodes using Nafion®
    Brown, FO
    Lowry, JP
    [J]. ANALYST, 2003, 128 (06) : 700 - 705
  • [7] Glutaraldehyde Cross-Linked Glutamate Oxidase Coated Microelectrode Arrays: Selectivity and Resting Levels of Glutamate in the CNS
    Burmeister, Jason J.
    Davis, Verda A.
    Quintero, Jorge E.
    Pomerleau, Francois
    Huettl, Peter
    Gerhardt, Greg A.
    [J]. ACS CHEMICAL NEUROSCIENCE, 2013, 4 (05): : 721 - 728
  • [8] Carstens E, 2000, ILAR J, V41, P62
  • [9] Microelectrode Biosensors for invivo Analysis of Brain Interstitial Fluid
    Chatard, Charles
    Meiller, Anne
    Marinesco, Stephane
    [J]. ELECTROANALYSIS, 2018, 30 (06) : 977 - 998
  • [10] GLUTAMATE NEUROTOXICITY AND DISEASES OF THE NERVOUS-SYSTEM
    CHOI, DW