Revisiting frequency domain analysis method for water hammer effects on pipeline systems

被引:2
作者
Ayed, Lazhar [1 ]
Hafsi, Zahreddine [1 ]
机构
[1] Univ Sfax, Natl Engn Sch Sfax, Lab Appl Fluids Mech Proc & Environm Engn, Sfax 3038, Tunisia
关键词
Water hammer; Impedance method; Resonance pulsations; Spectrum; LEAK DETECTION; BLOCKAGE DETECTION; PIPES;
D O I
10.1007/s40430-020-02693-9
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper revisits frequency domain analysis method for water hammer study in a hydraulic system. Detailed investigation of the effect of the flow parameters is conducted. Weaknesses on previous research works were pointed out. A brief presentation of the frequency response function determined from motions equations of transient water flow is firstly presented. A special emphasis was devoted to the effect of frictional flow on resonance pulsations. It was obtained that, unlike previous findings, resonance frequencies in a frictional flow are decayed from odd harmonics. This decay is more or less significant depending on the friction coefficient. The observations related to various effects are also illustrated through a set of test cases that were numerically analyzed. Additionally relative uncertainties highlighting the frictional flow effect on the accuracy of resonant pulsations detection are evaluated.
引用
收藏
页数:9
相关论文
共 44 条
  • [21] Transient frequency response based leak detection in water supply pipeline systems with branched and looped junctions
    Duan, Huan-Feng
    JOURNAL OF HYDROINFORMATICS, 2017, 19 (01) : 17 - 30
  • [22] Parametric analysis of water-hammer effects in small hydro schemes
    Ramos, H
    de Almeida, AB
    JOURNAL OF HYDRAULIC ENGINEERING, 2002, 128 (07) : 689 - 696
  • [23] Frequency-domain analysis of fluid-structure interaction in aircraft hydraulic pipeline systems: numerical and experimental studies
    Deng, Yang
    Jiao, Zongxia
    Xu, Yuanzhi
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2024, 25 (08): : 605 - 617
  • [24] A Frequency Domain Burst Detection Technique for Water Distribution Systems
    Zan, Thaw Tar Thein
    Lim, Hock Beng
    Wong, Kai-Juan
    Whittle, Andrew J.
    2011 IEEE SENSORS, 2011, : 1870 - 1873
  • [25] An investigation of data analysis method for hydraulic fracturing based on the water hammer effect
    Shen, Jianguo
    He, Huaiyin
    Li, Yanchao
    Zou, Longqing
    Wang, Yixuan
    Zhu, Zhaoying
    Guo, Lingkong
    Fu, Shuoran
    UNCONVENTIONAL RESOURCES, 2023, 3 : 284 - 290
  • [26] ANALYSIS OF WATER HAMMER IN THE REACTOR COOLANT SYSTEM BASED ON WAVE TRACKING METHOD
    Zhang, Qianping
    Dong, Shubiao
    Zhang, Xiaoyu
    PROCEEDINGS OF 2024 31ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 1, ICONE31 2024, 2024,
  • [27] Accuracy and Sensitivity Evaluation of TFR Method for Leak Detection in Multiple-Pipeline Water Supply Systems
    Duan, Huan-Feng
    WATER RESOURCES MANAGEMENT, 2018, 32 (06) : 2147 - 2164
  • [28] Study on the natural gas pipeline safety monitoring technique and the time-frequency signal analysis method
    Qu, Zhigang
    Wang, Yanfen
    Yue, Huanhuan
    An, Yang
    Wu, Liqun
    Zhou, Weibin
    Wang, Huayang
    Su, Zhichao
    Li, Jian
    Zhang, Yu
    Wang, Likun
    Yang, Xiliang
    Cai, Yuchen
    Yan, Daxian
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2017, 47 : 1 - 9
  • [29] Optimal Design for Shock Damper with Genetic Algorithm to Control Water Hammer Effects in Complex Water Distribution Systems
    Mohammad Bostan
    Ali Akbar Akhtari
    Hossein Bonakdari
    Farshad Jalili
    Water Resources Management, 2019, 33 : 1665 - 1681
  • [30] Optimal Design for Shock Damper with Genetic Algorithm to Control Water Hammer Effects in Complex Water Distribution Systems
    Bostan, Mohammad
    Akhtari, Ali Akbar
    Bonakdari, Hossein
    Jalili, Farshad
    WATER RESOURCES MANAGEMENT, 2019, 33 (05) : 1665 - 1681