Dual-Arm Robotic Needle Insertion With Active Tissue Deformation for Autonomous Suturing

被引:53
作者
Zhong, Fangxun [1 ,2 ]
Wang, Yaqing [1 ,2 ]
Wang, Zerui [1 ,2 ]
Liu, Yun-Hui [1 ,2 ]
机构
[1] Chinese Univ Hong Kong, T Stone Robot Inst, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Mech & Automat Engn, Shatin, Hong Kong, Peoples R China
来源
IEEE ROBOTICS AND AUTOMATION LETTERS | 2019年 / 4卷 / 03期
关键词
Surgical robotics: laparoscopy; sensor-based control; medical robots and systems; dual arm manipulation; MANIPULATION; PLACEMENT;
D O I
10.1109/LRA.2019.2913082
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
A major issue for needle insertion into soft tissue during suturing is the induced tissue deformation that hinders the minimization of tip-target positioning error. In this letter, we present a new robot control framework to solve target deviation by integrating active deformation control. We characterize the motion behavior of the desired target under needle-tissue interaction by introducing the needle-induced deformation matrix. Note that the modeling does not require the exact knowledge of tissue or needle insertion properties. The unknown parameters are online updated during the insertion procedure by an adaptive estimator via sensor-based measurement. A closed-loop controller is then proposed for dual-arm robotic execution upon image guidance. The dual-arm control aims to regulate a feature vector concerning the tip-target alignment to ensure target reachability. The feasibility of the proposed algorithm is studied via simulations and experiments on different biological tissues to simulate robotic minimally-invasive suturing using the da Vinci Research Kit as the control platform.
引用
收藏
页码:2669 / 2676
页数:8
相关论文
共 34 条
[1]   Integrating Deflection Models and Image Feedback for Real-Time Flexible Needle Steering [J].
Abayazid, Momen ;
Roesthuis, Roy J. ;
Reilink, Rob ;
Misra, Sarthak .
IEEE TRANSACTIONS ON ROBOTICS, 2013, 29 (02) :542-553
[2]   Sensorless Motion Planning for Medical Needle Insertion in Deformable Tissues [J].
Alterovitz, Ron ;
Goldberg, Kenneth Y. ;
Pouliot, Jean ;
Hsu, I-Chow .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (02) :217-225
[3]  
Atkins A. G., 1985, ELASTIC PLASTIC FRAC
[4]   New Technology and Health Care Costs - The Case of Robot-Assisted Surgery [J].
Barbash, Gabriel I. ;
Glied, Sherry A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (08) :701-704
[5]  
Barnett Andrew C, 2016, J MANUFACTURING SCI, V138, P1
[6]  
Chatelain P, 2015, IEEE INT CONF ROBOT, P2250, DOI 10.1109/ICRA.2015.7139497
[7]   Displacement of breast tissue and needle deviations during stereotactic procedures [J].
Deurloo, EE ;
Gilhuijs, KGA ;
Kool, LJS ;
Muller, SH .
INVESTIGATIVE RADIOLOGY, 2001, 36 (06) :347-353
[8]   Robot-assisted needle placement in open MRI: System architecture, integration and validation [J].
Dimaio, S. P. ;
Pieper, S. ;
Chinzei, K. ;
Hata, N. ;
Haker, S. J. ;
Kacher, D. F. ;
Fichtinger, G. ;
Tempany, C. M. ;
Kikins, R. .
COMPUTER AIDED SURGERY, 2007, 12 (01) :15-24
[9]   Needle steering and motion planning in soft tissues [J].
DiMaio, SP ;
Salcudean, SE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (06) :965-974
[10]  
Fung YC., 2013, BIOMECHANICS CIRCULA