Axial slip-friction connections for cross-laminated timber

被引:16
作者
Fitzgerald, Dillon [1 ,2 ]
Sinha, Arijit [3 ]
Miller, Thomas H. [2 ]
Nairn, John A. [3 ]
机构
[1] Oregon State Univ, Dept Wood Sci, Corvallis, OR 97331 USA
[2] Oregon State Univ, Sch Civil & Construct Engn, Corvallis, OR 97331 USA
[3] Oregon State Univ, Dept Wood Sci & Engn, Corvallis, OR 97331 USA
关键词
Cross-laminated timber; Slip-friction connection; Connection design; Damping; Seismic resiliency; Equivalent viscous damping; Screw roping; SHEAR WALL; PERFORMANCE; JOINTS;
D O I
10.1016/j.engstruct.2020.111478
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) rocking walls limit internal building forces and dissipate seismic energy mostly through severe connection damage and related wood crushing. While collapse-prevention and life-safety performance can be achieved, the connections and CLT walls are permanently damaged and may be unreliable for resisting aftershocks. Slip-friction connections (SFCs), also known as slotted-bolted connections, are highly resilient passive dampers originally developed for steel structures. As part of a thorough research program to apply SFCs to CLT rocking walls, connection tests were conducted to better understand a novel application of multiple modern timber technologies. The research objectives were to design and test a slip-friction connection connected to cross-laminated timber with inclined self-tapping screws (STS) to determine the stiffness and passive damping properties of the assembly. The SFC system was designed for use as a slip-friction hold-down in a self-centering CLT rocking wall system. A series of quasi-static, cyclic axial tests with slip-friction connections was shown to impart ductile and elastic-plastic characteristics to an otherwise non-ductile CLT connection. Because the timber connection forces were limited below the STS yield strength by the slip-friction connectors, no wood damage was observed during SFC sliding. Compared to other sources, passive damping was found to be excellent and close to typical idealized friction hysteresis models. The slip-friction connections are a unique design using an efficient CLT to SFC connection, with no slack, that performs consistently after consecutive tests. Additionally, cursory equivalent-viscous-damping ratios were extracted for the elastic range of the STS to steel connection for small amplitude excitations below the slip force threshold.
引用
收藏
页数:9
相关论文
共 37 条
  • [11] CEN, 2008, EUR 5 DES TIMB STRUC, V144, DOI [10.1680/, DOI 10.1680/]
  • [12] Chopra K.A., 2017, DYNAMICS STRUCTURES, V5th
  • [13] ANALYTICAL PREDICTIONS OF THE SEISMIC RESPONSE OF FRICTION DAMPED TIMBER SHEAR WALLS
    FILIATRAULT, A
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1990, 19 (02) : 259 - 273
  • [14] Fitzgerald D, 2019, J STRUCT ENG
  • [15] Fitzgerald D., 2019, THESIS
  • [16] Forest Products Laboratory, 2018, 2 MASS TIMB RES WORK
  • [17] Cyclic behaviour of typical metal connectors for cross-laminated (CLT) structures
    Gavric, Igor
    Fragiacomo, Massimo
    Ceccotti, Ario
    [J]. MATERIALS AND STRUCTURES, 2015, 48 (06) : 1841 - 1857
  • [18] Golondrino JC, 2012, NZSEE C 2012, P1
  • [19] Grigorian C.E., 1994, ENERGY DISSIPATION S
  • [20] Experimental Testing of Rocking Cross-Laminated Timber Walls with Resilient Slip Friction Joints
    Hashemi, Ashkan
    Zarnani, Pouyan
    Masoudnia, Reza
    Quenneville, Pierre
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (01)