The impact of global warming and building renovation measures on district heating system techno-economic parameters

被引:44
作者
Andric, I. [1 ,2 ,3 ]
Fournier, J. [2 ]
Lacarriere, B. [1 ]
Le Corre, O. [1 ]
Ferrao, P. [3 ]
机构
[1] UBL, GEPEA, Dept Energy Syst & Environm, IMT Atlantique, F-44307 Nantes, France
[2] Veolia Rech & Innovat, F-78520 Limay, France
[3] Inst Super Tecn, IN Ctr Innovat Technol & Policy Res, Av Rovisco Pais 1, P-1049001 Lisbon, Portugal
关键词
Global warming; Building renovation; District heating; Techno-economic analysis; ENERGY; NETWORKS; OPTIMIZATION; PROSUMERS; DEMAND; FUTURE;
D O I
10.1016/j.energy.2018.03.027
中图分类号
O414.1 [热力学];
学科分类号
摘要
Due to changing weather conditions caused by the global warming and building renovation measures triggered by new building energy efficiency policies, building heat demand in the future is likely to decrease. This effect could consequently impact the techno-economic parameters, feasibility and environmental performance of district heating (DH) systems. The main goal of this study is to evaluate the impact of global warming and building renovation on operational (heat generation) and economic parameters of district heating systems. As a case study, a prototypical district was created based on the district of St. Felix, which is located in Nantes (France). Weather and building renovation scenarios were developed for the 2010-2050 period, with a ten-year time step. Heat demand for all scenarios was calculated with a model based on thermo-electrical analogy, previously developed and validated by the authors, while the network techno-economic parameters were calculated using a tool developed by Veolia Research and Innovation for the internal corporate use. The results indicated that the decrease of heat demand proved to be the highest after the first year of renovation (2020), decreasing by 52% of the reference value (2010). Accordingly, DH linear heat density decreases bellow the profitability minimum for traditional district heating networks. The participation of natural gas peak boiler in heat production increases over the studied period, while the participation of base load biomass boiler decreases, due to the fact that the number of hours with heat demand bellow the technical limit of the base load boiler was increasing. Consequently, CO2 emission levels increased. Heat production costs increased, with higher increase rate for the scenario where the new district heating network is planned, compared to the scenario with an existing network. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:926 / 937
页数:12
相关论文
共 48 条
  • [1] The impact of climate change on building heat demand in different climate types
    Andric, I.
    Pina, Andre
    Ferrao, Paulo
    Fournier, Jeremy
    Lacarriere, Bruno
    Le Corre, Olivier
    [J]. ENERGY AND BUILDINGS, 2017, 149 : 225 - 234
  • [2] Modeling the long-term effect of climate change on building heat demand: Case study on a district level
    Andric, I.
    Gomes, N.
    Pina, A.
    Ferrao, P.
    Fournier, J.
    Lacarriere, B.
    Le Corre, O.
    [J]. ENERGY AND BUILDINGS, 2016, 126 : 77 - 93
  • [3] [Anonymous], 2014, Climate Change 2014: Synthesis Report. Contribution of Working Groups I
  • [4] APUR (Atelier Parisien d'Urbanisme), 2007, AT PAR URB 2007
  • [5] AutoDesk, 2015, REVIT PROD OCC SCHED
  • [6] Experimental determination of heat losses from buried district heating pipes in normal operation
    Bohm, B
    [J]. HEAT TRANSFER ENGINEERING, 2001, 22 (03) : 41 - 51
  • [7] Smart district heating networks - A simulation study of prosumers' impact on technical parameters in distribution networks
    Brand, Lisa
    Calven, Alexandra
    Englund, Jessica
    Landersjo, Henrik
    Lauenburg, Patrick
    [J]. APPLIED ENERGY, 2014, 129 : 39 - 48
  • [8] Prosumers in district heating networks - A Swedish case study
    Brange, Lisa
    Englund, Jessica
    Lauenburg, Patrick
    [J]. APPLIED ENERGY, 2016, 164 : 492 - 500
  • [9] Buildings Performance Institute Europe (BPIE), 2015, DAT HUB EN PERF BUIL