Safety and efficacy of a novel double-lumen tracheal tube in neonates with RDS: A prospective cohort study

被引:0
|
作者
Li, Chuanfeng [1 ]
Du, Yuxuan [2 ,3 ,4 ,5 ,6 ]
Yang, Kaiting [1 ]
Cao, Huiling [2 ,3 ,4 ,5 ,6 ]
Yang, Hong [1 ]
Zhang, ChunXiu [1 ]
Li, Xiongbin [1 ]
Deng, Xingmei [1 ]
Shi, Yuan [2 ,3 ,4 ,5 ,6 ]
机构
[1] Qujing Matern & Child Healthcare Hosp, Dept Neonatol, Qujing, Yunnan, Peoples R China
[2] Chongqing Med Univ, Childrens Hosp, Dept Neonatol, Chongqing, Peoples R China
[3] Natl Clin Res Ctr Child Hlth & Disorders, Chongqing, Peoples R China
[4] Minist Educ, Key Lab Child Dev & Disorders, Chongqing, Peoples R China
[5] China Int Sci & Technol Cooperat Base Child Dev &, Chongqing, Peoples R China
[6] Chongqing Key Lab Pediat, Chongqing, Peoples R China
来源
FRONTIERS IN PEDIATRICS | 2022年 / 10卷
关键词
newborn resuscitation; endotracheal intubation; invasive mechanical ventilation; respiratory distress syndrome; surfactant replacement therapy; RESPIRATORY-DISTRESS-SYNDROME; SURFACTANT-REPLACEMENT THERAPY; PRETERM INFANTS; RANDOMIZED-TRIAL; EXTUBATION; VENTILATION; MANAGEMENT; OUTCOMES; CPAP;
D O I
10.3389/fped.2022.1032044
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background The purpose of this study was to assess the safety and efficacy of a new double-lumen tracheal tube for neonates, with a conventional tracheal tube as a control.Method Newborns with respiratory distress syndrome (RDS) requiring endotracheal intubation admitted to the tertiary neonatal intensive care unit (NICU) of Qujing Maternal and Child Healthcare Hospital in Yunnan Province between March 2021 and May 2022 were enrolled in this prospective cohort study. Outcome indicators related to effectiveness included mainly the number of intubations, duration of ventilation, duration of oxygenation, and length of stay; safety indicators included any clinical adverse effects during and after intubation. Appropriate stratified and subgroup analyses were performed according to the purpose of intubation, gestational age, and whether the drug was administered via endotracheal tube.Result A total of 101 neonates were included and divided into two groups based on the choice of tracheal tube: the conventional (n = 50) and new (n = 51) tracheal tube groups. There was no statistical difference between the two groups in terms of adverse effects during and after intubation (p > 0.05). In neonates who were mechanically ventilated without endotracheal surfactant therapy or newborns receiving InSurE technique followed by non-invasive ventilation, no significant differences were found between the two groups regarding any of the efficacy indicators (p > 0.05). However, for neonates on invasive mechanical ventilation, the new tracheal tube allowed for a significant reduction in the duration of mechanical ventilation (96.50[74.00, 144.00] vs. 121.00[96.00, 196.50] hours, p = 0.037) and total ventilation (205.71 & PLUSMN; 80.24 vs. 277.56 & PLUSMN; 117.84 h, p = 0.027), when used as a route for endotracheal drug delivery. Further analysis was performed according to gestational age for newborns requiring intratracheal surfactant administration during mechanical ventilation, and the data showed that for preterm infants, the new tracheal tube not only shortened the duration of mechanical ventilation (101.75 & PLUSMN; 39.72 vs. 155.50 & PLUSMN; 51.49 h, p = 0.026) and total ventilation (216.00 & PLUSMN; 81.60 vs. 351.50 & PLUSMN; 113.79 h, p = 0.010), but also demonstrated significant advantages in reducing the duration of oxygen therapy (9.75 & PLUSMN; 6.02 vs. 17.33 & PLUSMN; 8.43 days, p = 0.042); however, there was no statistical difference in efficacy outcomes between the two groups in full-term infants (p > 0.05).Conclusion The efficacy and safety of this new tracheal tube are promising in neonates with RDS, especially those requiring surfactant administration via a tracheal tube during mechanical ventilation. Given the limitations of this study, however, the clinical feasibility of this catheter needs to be further confirmed in prospective randomized trials with larger sample sizes.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Iatrogenic Tracheal Rupture during Intubation with a Double-Lumen Tube
    Tezel, C.
    Okur, E.
    Baysungur, V.
    THORACIC AND CARDIOVASCULAR SURGEON, 2010, 58 (01): : 54 - U4
  • [2] Efficacy of Bonfils fiberoptic stylet for difficult tracheal intubation with double lumen tube: A prospective observational study
    Falcetta, Stefano
    Bartolini, Federica
    Carsetti, Andrea
    Sorbello, Massimiliano
    Gentili, Paolo
    Coltrinari, Rosanna
    Cortese, Gerardo
    Godoroja, Daniela
    Refai, Majed
    Donati, Abele
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2022, 47 : 1 - 6
  • [3] Avoidable tracheal injury using a double-lumen endotracheal tube: a case report
    Lemay, Judith
    Conti, Massimo
    Somma, Jacques
    Vigneault, Louise
    Bussieres, Jean S.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2018, 65 (06): : 735 - 736
  • [4] The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers
    Ghosh, S.
    Klein, A. A.
    Prabhu, M.
    Falter, F.
    Arrowsmith, J. E.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (03) : 424 - 428
  • [5] Evaluation of a new double-lumen endobronchial tube with an integrated camera (VivaSight-DL™): a prospective multicentre observational study
    Koopman, E. M.
    Barak, M.
    Weber, E.
    Valk, M. J. A.
    de Schepper, R. T. I.
    Bouwman, R. A.
    Huitink, J. M.
    ANAESTHESIA, 2015, 70 (08) : 962 - 968
  • [6] Evaluation of the Double-Lumen Tube Vivasight-DL (DLT-ETView): A Prospective Single-Center Study
    Massot, Julien
    Dumand-Nizard, Virginie
    Fischler, Marc
    Le Guen, Morgan
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (06) : 1544 - 1549
  • [7] Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial
    Yi, Jie
    Gong, Yahong
    Quan, Xiang
    Huang, Yuguang
    BMC ANESTHESIOLOGY, 2015, 15
  • [8] Double-lumen tracheal tubes and bougies: a bench study to investigate factors that influence the risk of shearing
    Luther, D. G. P.
    Robertson, H. F.
    Suchett-Kaye, I.
    Birch, A.
    Molyneux, M.
    ANAESTHESIA, 2019, 74 (07) : 891 - 895
  • [9] Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study
    Steinmann, D.
    Stahl, C. A.
    Minner, J.
    Schumann, S.
    Loop, T.
    Kirschbaum, A.
    Priebe, H. J.
    Guttmann, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (03) : 411 - 418
  • [10] A spray-as-you-go airway topical anesthesia attenuates cardiovascular responses for double-lumen tube tracheal intubation
    Chen, Changlin
    Wen, Di
    Wang, Yizheng
    Li, Hongqiong
    Yu, Qi
    Li, Mao
    BMC ANESTHESIOLOGY, 2022, 22 (01)