摘要
AimRotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. MethodsWe included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). ResultsThe mean age of the study population was 6110years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 +/- 825.3Gym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 +/- 5.5min. ConclusionTSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 16 条
  • [1] Added value of transoesophageal echocardiography during transseptal puncture performed by inexperienced operators
    Bayrak, Fatih
    Chierchia, Gian-Battista
    Namdar, Mehdi
    Yazaki, Yoshinao
    Sarkozy, Andrea
    de Asmundis, Carlo
    Muller-Burri, Stephan Andreas
    Rao, Jayakeerthi
    Ricciardi, Danilo
    Sorgente, Antonio
    Brugada, Pedro
    [J]. EUROPACE, 2012, 14 (05): : 661 - 665
  • [2] 2012 focused update of the ESC Guidelines for the management of atrial fibrillation
    Camm, A. John
    Lip, Gregory Y. H.
    De Caterina, Raffaele
    Savelieva, Irene
    Atar, Dan
    Hohnloser, Stefan H.
    Hindricks, Gerhard
    Kirchhof, Paulus
    Bax, Jeroen J.
    Baumgartner, Helmut
    Ceconi, Claudio
    Dean, Veronica
    Deaton, Christi
    Fagard, Robert
    Funck-Brentano, Christian
    Hasdai, David
    Hoes, Arno
    Knuuti, Juhani
    Kolh, Philippe
    McDonagh, Theresa
    Moulin, Cyril
    Popescu, Bogdan A.
    Reiner, Zeljko
    Sechtem, Udo
    Sirnes, Per Anton
    Tendera, Michal
    Torbicki, Adam
    Vahanian, Alec
    Windecker, Stephan
    Vardas, Panos
    Al-Attar, Nawwar
    Alfieri, Ottavio
    Angelini, Annalisa
    Blomstrom-Lundqvist, Carina
    Colonna, Paolo
    De Sutter, Johan
    Ernst, Sabine
    Goette, Andreas
    Gorenek, Bulent
    Hatala, Robert
    Heidbuchel, Hein
    Heldal, Magnus
    Kristensen, Steen Dalby
    Le Heuzey, Jean-Yves
    Mavrakis, Hercules
    Mont, Lluis
    Filardi, Pasquale Perrone
    Ponikowski, Piotr
    Prendergast, Bernard
    Rutten, Frans H.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 (21) : 2719 - 2747
  • [3] Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation
    Cappato, Riccardo
    Calkins, Hugh
    Chen, Shih-Ann
    Davies, Wyn
    Iesaka, Yoshito
    Kalman, Jonathan
    Kim, You-Ho
    Klein, George
    Natale, Andrea
    Packer, Douglas
    Skanes, Allan
    Ambrogi, Federico
    Biganzoli, Elia
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) : 32 - 38
  • [4] First experience with real-time three-dimensional transoesophageal echocardiography-guided transseptal in patients undergoing atrial fibrillation ablation
    Chierchia, Gian Battista
    Capulzini, Lucio
    de Asmundis, Carlo
    Sarkozy, Andrea
    Roos, Markus
    Paparella, Gaetano
    Boussy, Tim
    Van Camp, Guy
    Kerkhove, Dirk
    Brugada, Pedro
    [J]. EUROPACE, 2008, 10 (11): : 1325 - 1328
  • [5] Integrated x-ray and echocardiography imaging for structural heart interventions
    Corti, Roberto
    Biaggi, Patric
    Gaemperli, Oliver
    Buehler, Ines
    Felix, Christian
    Bettex, Dominique
    Kretschmars, Oliver
    Falk, Volkmar
    Gruenenfelder, Juerg
    [J]. EUROINTERVENTION, 2013, 9 (07) : 863 - 869
  • [6] Cardiac three-dimensional rotational angiography can be performed with low radiation dose while preserving image quality
    De Buck, Stijn
    Alzand, Becker S. N.
    Wielandts, Jean-Yves
    Garweg, Christophe
    Phlips, Thomas
    Ector, Joris
    Nuyens, Dieter
    Heidbuchel, Hein
    [J]. EUROPACE, 2013, 15 (12): : 1718 - 1724
  • [7] Trans-septal catheterization in the electrophysiology laboratory - Data from a multicenter survey spanning 12 years
    De Ponti, R
    Cappato, R
    Curnis, A
    Della Bella, P
    Padeletti, L
    Raviele, A
    Santini, M
    Salerno-Uriarte, JA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (05) : 1037 - 1042
  • [8] How to perform a transseptal puncture
    Earley, Mark J.
    [J]. HEART, 2009, 95 (01) : 85 - 92
  • [9] Nonfluoroscopic transseptal catheterization: Safety and efficacy of intracardiac echocardiographic guidance
    Epstein, LM
    Smith, T
    TenHoff, H
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (06) : 625 - 630
  • [10] Usefulness of intracardiac echocardiography in complex transseptal catheterization during percutaneous transvenous mitral commissurotomy
    Hung, JS
    Fu, M
    Yeh, KH
    Wu, CJ
    Wong, P