Development and application of a UPLC-MS/MS method for P-glycoprotein quantification in human tumor cells

被引:8
|
作者
Qiu, Zhaohui [1 ]
Peng, Jie [1 ]
Mou, Lingli [2 ]
Li, Xiao [3 ]
Meng, Fanqi [1 ]
Yu, Peng [1 ]
机构
[1] Cent S Univ, Sch Xiangya Pharmaceut Sci, 172 Tong Zi Po Rd, Changsha 410013, Hunan, Peoples R China
[2] Hunan Normal Univ, Med Coll, 371 Tong Zi Po Rd, Changsha 410006, Hunan, Peoples R China
[3] Changsha Duxact Biotech Co Ltd, C10 Bldg,Lugu S&T Pk,28 Lutian Rd, Changsha 411000, Hunan, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2018年 / 1084卷
关键词
UPLC-MS/MS; P-gp quantification; Human tumor cells; Linear regression; TANDEM MASS-SPECTROMETRY; MEDIATED MULTIDRUG-RESISTANCE; TARGETED PROTEOMICS; DRUG TRANSPORTERS; EXPRESSION; QUANTITATION; PROTEINS; PROLIFERATION;
D O I
10.1016/j.jchromb.2018.03.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multidrug resistance (MDR) of tumors occurs when tumor cells exhibit reduced sensitivity to a large number of unrelated drugs. The molecular mechanism of MDR commonly involves overexpression of the plasma membrane drug efflux pump P-glycoprotein (P-gp). Overexpression of P-gp may be induced by the selection and/or adaptation of cells during exposure to chemotherapeutic drugs, referred to as acquired P-gp-mediated MDR. This study aimed to establish a P-gp quantification method by Ultra Performance Liquid Chromatography and Tandem Mass Spectrometry (UPLC-MS/MS) to better understand the regulation of P-gp expression and its relationship with the level of drug resistance. Absolute P-gp expression was determined in the human tumor cells MCF-7, HepG-2, and SMMC-7721 and their corresponding drug-resistant subclones MCF-7/ADMs, MCF-7MXs, MCF-7/MTXs, HepG-2/ADMs, HepG-2/MXs, HepG-2/MIXs, SMMC-7721/ADMs, SMMC-7721/MXs and SMMC-7721/MTXs. A unique 10-mer Cryptic peptide (IATEAIENFR) of P-gp was synthesized for developing the quantitative UPLC-MS/MS method with the stable isotope labeled signature peptide IATEAI (C-13(6), N-15(1)) ENFR as the internal standard (IS). The detection signal was linear in the range of 0.1-100 ng mL(-1). Quality control (QC) data showed that the within-run and between-run precision (%RSD) and accuracy (%RE) conformed to acceptable criteria of +/- 15% for the calibration standards and QCs (+/- 20% at the LLOQ). The UPLC-MS/MS method was first applied to quantify P-gp in HepG-2 and SMMC-7721 cells and their drug-resistant subclones. The results confirmed that P-gp expression in most drug-resistant subclones increase significantly compared to parental tumor cells but varied among different types of drugs or tumor cells. This outcome was then compared with published reports and discrepancy was observed in HepG2 cell lines mainly due to different sample types and samples sources. Additionally, P-gp mRNA results ascertained that overexpression of P-gp in subclones was not only regulated by MDR1. The linear correlation between RI and logarithm-transformed P-gp expression was moderate or high and statistically significantly different in subclones, except for SMMC-7721/ADMs. The present study is the first to demonstrate the quantitative relationship between RI and P-gp expression by linear regression modeling and expanded the number of efflux transporters related to MDR quantifiable by LC-MS/MS to better understand the biological significance of effluent transporter expression.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 50 条
  • [21] Development of UPLC-MS/MS method for analyzing phorate: application to wastewater treatment
    Rajashree R. Yaragal
    Devendra Kumar
    Srikanth Mutnuri
    Journal of the Iranian Chemical Society, 2020, 17 : 2923 - 2931
  • [22] Development and validation of an UPLC-MS/MS method for the quantification of tamoxifen and its main metabolites in human scalp hair
    Drooger, Jan C.
    Jager, Agnes
    Lam, Mei-Ho
    den Boer, Mathilda D.
    Sleijfer, Stefan
    Mathijssen, Ron H. J.
    de Bruijn, Peter
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 114 : 416 - 425
  • [23] UPLC-MS/MS method for the quantification of ertugliflozin and sitagliptin in rat plasma
    Qiu, Xiangjun
    Xie, Saili
    Ye, Lei
    Xu, Ren-ai
    ANALYTICAL BIOCHEMISTRY, 2019, 567 : 112 - 116
  • [24] Development and validation of a rapid and sensitive UPLC-MS/MS method for quantification of kukoamine B in human plasma: Application to a clinical pharmacokinetic study
    Wang, Zhenlei
    Zhao, Qian
    Li, Lili
    Hu, Pei
    Dong, Kai
    Chen, Shuai
    Jiang, Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 132 : 1 - 6
  • [25] Development of UPLC-MS/MS Method for Quantitative Analysis of Curcumin in Human Plasma
    Hayun, Hayun
    Rahmawati, Rina
    Harahap, Yahdiana
    Sari, Santi Purna
    ACTA CHROMATOGRAPHICA, 2018, 30 (04) : 207 - 211
  • [26] An UPLC-MS/MS method for the analysis of glimepiride and fluoxetine in human plasma
    Qiu, Xiangjun
    Wang, Hong-wei
    Yuan, Ye
    Wang, Ying-fei
    Sun, Ming
    Huang, Xue-sun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 980 : 16 - 19
  • [27] Development and validation of a UPLC-MS/MS method for quantitation of droxidopa in human plasma: Application to a pharmacokinetic study
    Wang, Haidong
    Yang, Guangsheng
    Zhou, Jinyu
    Pei, Jiang
    Zhang, Qiangfeng
    Song, Xingfa
    Sun, Zengxian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1027 : 234 - 238
  • [28] An UPLC-MS/MS Method for Routine Quantification of Insulin Degludec in Plasma
    Zhang, Yudong
    Jiang, Yue
    Wang, Ya
    Wang, Ling
    Han, Weijie
    Cheng, Xiaoyi
    Deng, Xue
    Qin, Chunmeng
    Liu, Yan
    CURRENT PHARMACEUTICAL ANALYSIS, 2020, 16 (06) : 792 - 799
  • [29] An UPLC-MS detection method for the quantification of five antibiotics in human plasma
    Chahbouni, Abdel
    van den Dungen, Frank A. M.
    Vos, Rene M.
    den Burger, Jeroen C.
    Sinjewel, Amo
    Wilhelm, Abraham J.
    Veldkamp, Agnes I.
    Swart, Eleanor L.
    van Weissenbruch, Mirjam M.
    BIOANALYSIS, 2015, 7 (18) : 2321 - 2329
  • [30] Development and validation of a rapid and sensitive UPLC-MS/MS assay for the quantification of tofacitinib in human plasma
    Bharwad, Kirtikumar D.
    Shah, Priyanka A.
    Shrivastav, Pranav S.
    Singhal, Puran
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (04)