Occurrence and Type of Adverse Events During the Use of Stationary Gait Robots-A Systematic Literature Review

被引:26
作者
Bessler, Jule [1 ,2 ]
Prange-Lasonder, Gerdienke B. [1 ,3 ]
Schulte, Robert V. [1 ,2 ]
Schaake, Leendert [1 ]
Prinsen, Erik C. [1 ,3 ]
Buurke, Jaap H. [1 ,2 ]
机构
[1] Roessingh Res & Dev, Enschede, Netherlands
[2] Univ Twente, Dept Biomed Signals & Syst, Enschede, Netherlands
[3] Univ Twente, Dept Biomech Engn, Enschede, Netherlands
关键词
robot-assisted gait training; adverse event (AE); safety; physical human-robot interaction (pHRI); injuries (MeSH); stationary gait robots; rehabilitation robotics; SPINAL-CORD-INJURY; WEIGHT SUPPORTED TREADMILL; DIRECT-CURRENT STIMULATION; PARTIAL-BODY-WEIGHT; STROKE PATIENTS; PARKINSONS-DISEASE; PILOT; REHABILITATION; EXOSKELETON; SUPERIOR;
D O I
10.3389/frobt.2020.557606
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Robot-assisted gait training (RAGT) devices are used in rehabilitation to improve patients' walking function. While there are some reports on the adverse events (AEs) and associated risks in overground exoskeletons, the risks of stationary gait trainers cannot be accurately assessed. We therefore aimed to collect information on AEs occurring during the use of stationary gait robots and identify associated risks, as well as gaps and needs, for safe use of these devices. We searched both bibliographic and full-text literature databases for peer-reviewed articles describing the outcomes of stationary RAGT and specifically mentioning AEs. We then compiled information on the occurrence and types of AEs and on the quality of AE reporting. Based on this, we analyzed the risks of RAGT in stationary gait robots. We included 50 studies involving 985 subjects and found reports of AEs in 18 of those studies. Many of the AE reports were incomplete or did not include sufficient detail on different aspects, such as severity or patient characteristics, which hinders the precise counts of AE-related information. Over 169 device-related AEs experienced by between 79 and 124 patients were reported. Soft tissue-related AEs occurred most frequently and were mostly reported in end-effector-type devices. Musculoskeletal AEs had the second highest prevalence and occurred mainly in exoskeleton-type devices. We further identified physiological AEs including blood pressure changes that occurred in both exoskeleton-type and end-effector-type devices. Training in stationary gait robots can cause injuries or discomfort to the skin, underlying tissue, and musculoskeletal system, as well as unwanted blood pressure changes. The underlying risks for the most prevalent injury types include excessive pressure and shear at the interface between robot and human (cuffs/harness), as well as increased moments and forces applied to the musculoskeletal system likely caused by misalignments (between joint axes of robot and human). There is a need for more structured and complete recording and dissemination of AEs related to robotic gait training to increase knowledge on risks. With this information, appropriate mitigation strategies can and should be developed and implemented in RAGT devices to increase their safety.
引用
收藏
页数:17
相关论文
共 84 条
[1]   Voluntary driven exoskeleton as a new tool for rehabilitation in chronic spinal cord injury: a pilot study [J].
Aach, Mirko ;
Cruciger, Oliver ;
Sczesny-Kaiser, Matthias ;
Hoeffken, Oliver ;
Meindl, Renate Ch. ;
Tegenthoff, Martin ;
Schwenkreis, Peter ;
Sankai, Yoshiyuki ;
Schildhauer, Thomas A. .
SPINE JOURNAL, 2014, 14 (12) :2847-2853
[2]  
Akiyama Y., 2012, 2012 RO-MAN: The 21st IEEE International Symposium on Robot and Human Interactive Communication, P539, DOI 10.1109/ROMAN.2012.6343807
[3]   Interaction forces beneath cuffs of physical assistant robots and their motion-based estimation [J].
Akiyama, Yasuhiro ;
Yamada, Yoji ;
Okamoto, Shogo .
ADVANCED ROBOTICS, 2015, 29 (20) :1315-1329
[4]   A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses [J].
Alavi, N. ;
Zampierin, S. ;
Komeili, M. ;
Cocuzza, S. ;
Debei, S. ;
Menon, C. .
BIOMEDICAL ENGINEERING ONLINE, 2017, 16
[5]   A biologically inspired soft exosuit for walking assistance [J].
Asbeck, Alan T. ;
De Rossi, Stefano M. M. ;
Holt, Kenneth G. ;
Walsh, Conor J. .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2015, 34 (06) :744-762
[6]   Can Lokomat therapy with children and adolescents be improved? An adaptive clinical pilot trial comparing Guidance force, Path control, and FreeD [J].
Aurich-Schuler, Tabea ;
Grob, Fabienne ;
van Hedel, Hubertus J. A. ;
Labruyere, Rob .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14
[7]   Bioengineering considerations in the prevention of medical device-related pressure ulcers [J].
Bader, D. L. ;
Worsley, P. R. ;
Gefen, A. .
CLINICAL BIOMECHANICS, 2019, 67 :70-77
[8]   Comparison of the effects on dynamic balance and aerobic capacity between objective and subjective methods of high-intensity robot-assisted gait training in chronic stroke patients: a randomized controlled trial [J].
Bae, Young-Hyeon ;
Lee, Suk Min ;
Ko, Mansoo .
TOPICS IN STROKE REHABILITATION, 2017, 24 (04) :309-313
[9]   Training modalities in robot-mediated upper limb rehabilitation in stroke: a framework for classification based on a systematic review [J].
Basteris, Angelo ;
Nijenhuis, Sharon M. ;
Stienen, Arno H. A. ;
Buurke, Jaap H. ;
Prange, Gerdienke B. ;
Amirabdollahian, Farshid .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
[10]  
Behrens R, 2014, IEEE INT CONF ROBOT, P3378, DOI 10.1109/ICRA.2014.6907345