Trial for Monitoring the Water Temperature Utilizing the Frequency Dependence of Reflection Coefficient of Ultrasound Passing Through Thin Layer

被引:3
|
作者
Tohmyoh, Hironori [1 ]
Terashima, Shu [1 ]
机构
[1] Tohoku Univ, Dept Finemech, Aoba Ku, Aoba 6-6-01, Sendai, Miyagi 9808579, Japan
来源
JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS | 2019年 / 2卷 / 02期
基金
日本学术振兴会;
关键词
ultrasound; acoustic resonance; reflection coefficient; thin film; water temperature;
D O I
10.1115/1.4042871
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes a new concept to monitor the temperature of water utilizing the acoustic resonance, which occurs when ultrasound passes through a thin layer. In the ultrasonic transmission system that comprises of the reflection plate, thin film, and water, the reflection coefficient of the ultrasound at the plate/film/water interface depends on the frequency and takes its minimum value at the resonant frequency. Notably, this is closely related to the acoustic impedance of the water; moreover, it is a known fact that the acoustic impedance of the water demonstrates temperature dependence. Against this background, the present study aims to develop a technique in order to monitor the temperature of water utilizing the aforementioned correlation between the reflection coefficient and water temperature. First, a theoretical model was developed to determine the acoustic impedance of water from the difference in the amplitude spectra of echoes reflected at the back of the plate in the cases both with and without the film. It was found that the ratio of the amplitude spectrum of the echo recorded in the case with the film to that in the case without the film clearly decreased with a drop in water temperature. From this, we obtained the equation for determining water temperature experimentally. Finally, the temperature of water, which was brought down by air or ice cooling, was monitored by the proposed method. It was found that the behavior of temperature determined by the proposed method was congruent with that which was measured by a thermocouple.
引用
收藏
页数:6
相关论文
共 2 条
  • [1] Measurement of the frequency dependence of the ultrasonic reflection coefficient from thin interface layers and partially contacting interfaces
    Drinkwater, BW
    Cawley, P
    ULTRASONICS, 1997, 35 (07) : 479 - 488
  • [2] Temperature dependence of vibrational motions of thin polystyrene films by infrared reflection-absorption spectroscopy: A single measurement tool for monitoring of glass transition and temperature history
    Hanulikova, Barbora
    Capkova, Tereza
    Antos, Jan
    Urbanek, Michal
    Urbanek, Pavel
    Sevcik, Jakub
    Kuritka, Ivo
    POLYMER TESTING, 2021, 101