A Fully Adaptive PMU-Based Fault Location Algorithm for Series-Compensated Lines

被引:45
作者
Al-Mohammed, Ali H. [1 ]
Abido, M. A. [2 ,3 ]
机构
[1] Saudi Elect Co, Dammam, Saudi Arabia
[2] KFUPM, Dept Elect Engn, Dhahran, Saudi Arabia
[3] Menoufia Univ, Dept Elect Engn, Fac Engn, Shibin Al Kawm, Egypt
关键词
Fault location; phasor measurement unit (PMU); series compensated lines; synchronized phasor measurements; synchrophasor; wide area monitoring; NETWORK;
D O I
10.1109/TPWRS.2014.2303207
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a fully adaptive fault location algorithm for series-compensated lines (SCLs) based on synchronized phasor measurements obtained by phasor measurement units (PMUs). The proposed algorithm does not require any knowledge on the exact model of the series-compensation device and, therefore, can be applied to transmission lines with any type of series compensation. In addition, the proposed algorithm utilizes only PMU synchronized measurements and does not require any data to be provided by the electric utility. The SCL parameters and Thevenin's equivalent (TE) of the system at SCL terminals are determined online, utilizing three independent sets of pre-fault PMU measurements, to ensure considering the actual operating conditions of the system. Fault-location accuracy evaluation of the proposed algorithm is performed with respect to various factors such as fault position, fault type, fault resistance, fault inception angle, pre-fault loading and line compensation degree. The proposed algorithm is simulated using both PSCAD/EMTDC and MATLAB and tested on a 400-kV system. Simulation results revealed that the developed algorithm is capable of producing reliable and highly accurate solutions.
引用
收藏
页码:2129 / 2137
页数:9
相关论文
共 35 条
[1]  
Abdelkader S., 2010, INT C REN EN POW QUA, P1
[2]   Using instantaneous values for estimating fault locations on series compensated transmission lines [J].
Al-Dabbagh, M ;
Kapuduwage, SK .
ELECTRIC POWER SYSTEMS RESEARCH, 2005, 76 (1-3) :25-32
[3]  
Al-Mohy A.H., 2010, PhD Thesis. Faculty of Engineering and Physical Sciences, University of Manchester, Manchester, P1
[4]  
[Anonymous], 2009, P IPST KYOT JAP
[5]   Accurate fault location algorithm for double-circuit series compensated lines using a limited number of two-end synchronized measurements [J].
Apostolopoulos, C. A. ;
Korres, G. N. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) :495-507
[6]   A Novel Algorithm for Locating Faults on Transposed/Untransposed Transmission Lines Without Utilizing Line Parameters [J].
Apostolopoulos, Christos A. ;
Korres, George N. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :2328-2338
[7]  
Bo W., 2009, Sustainable Power Generation and Supply, P1
[8]  
Borda C, 2009, POW SYST C EXP 2009, P1
[9]   Fault location on parallel transmission lines with series compensation [J].
Dutra, R ;
Fabiano, L ;
Saha, MM ;
Lidström, S .
2004 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, 2004, :591-597
[10]  
El Din EST, 2006, ELECTR POW SYST RES, V76, P928, DOI [10.1016/j.epsr.2005.07.008, 10.1016/j.epsr.2005.07.005]