Stability of crestal bone level at platform-switched non-submerged titanium implants: a histomorphometrical study in dogs

被引:68
作者
Becker, Juergen [1 ]
Ferrari, Daniel [1 ]
Mihatovic, Ilja [1 ]
Sahm, Narja [1 ]
Schaer, Alex [2 ]
Schwarz, Frank [1 ]
机构
[1] Univ Dusseldorf, Dept Oral Surg, W Deutsch Kieferklin, D-40225 Dusseldorf, Germany
[2] Camlog Biotechnol AG, Basel, Switzerland
关键词
animal study; crestal bone level; histomorphometry; platform switching; HISTOMETRIC EVALUATION; MUCOSA;
D O I
10.1111/j.1600-051X.2009.01413.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Becker J, Ferrari D, Mihatovic I, Sahm N, Schaer A, Schwarz F. Stability of crestal bone level at platform switched non-submerged titanium implants. a histomorphometrical study in dogs. J Clin Periodontol 2009; 36: 532-539. doi: 10.1111/j.1600-051X.2009.01413.x. To investigate the influence of platform switching on crestal bone level changes at non-submerged titanium implants over a period of 6 months. Titanium implants (n=72) were placed at 0.4 mm above the alveolar crest in the lower jaws of 12 dogs and randomly assigned to either matching or non-matching (circumferential horizontal mismatch of 0.3 mm) healing abutments. At 4, 8, 12, and 24 weeks, dissected blocks were processed for histomorphometrical analysis. Measurements were made between the implant shoulder (IS) and the apical extension of the long junctional epithelium (aJE), the most coronal level of bone in contact with the implant (CLB), and the level of the alveolar bone crest (BC). At 24 weeks, differences in the mean IS-aJE, IS-CLB, and IS-BC values were 0.2 +/- 1.2, 0.3 +/- 0.7, and 0.3 +/- 0.8 mm at the buccal aspect, and 0.2 +/- 0.9, 0.3 +/- 0.5, and 0.3 +/- 0.8 mm at the lingual aspect, respectively. Comparisons between groups revealed no significant differences at either the buccal or the lingual aspects. It was concluded that (i) bone remodelling was minimal in both groups and (ii) platform switching may not be of crucial importance for maintenance of the crestal bone level.
引用
收藏
页码:532 / 539
页数:8
相关论文
共 23 条
[1]   The mucosal barrier following abutment dis/reconnection - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (08) :568-572
[2]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[3]   Ridge alterations following implant placement in fresh extraction sockets:: an experimental study in the dog [J].
Araújo, MG ;
Sukekava, F ;
Wennström, JL ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (06) :645-652
[4]   Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs [J].
Becker, Juergen ;
Ferrari, Daniel ;
Herten, Monika ;
Kirsch, Axel ;
Schaer, Alex ;
Schwarz, Frank .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (12) :1089-1096
[5]   Spontaneous progression of ligature induced peri-implantitis at implants with different surface roughness: an experimental study in dogs [J].
Berglundh, T. ;
Gotfredsen, K. ;
Zitzmann, N. U. ;
Lang, N. P. ;
Lindhe, J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (05) :655-661
[6]   Dimension of the periimplant mucosa - Biological width revisited [J].
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (10) :971-973
[7]   Morphogenesis of the peri-implant mucosa: an experimental study in dogs [J].
Berglundh, Tord ;
Abrahamsson, Ingemar ;
Welander, Maria ;
Lang, Niklaus P. ;
Lindhe, Jan .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (01) :1-8
[9]  
ERICSSON I, 1995, J CLIN PERIODONTOL, V22, P255
[10]   Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible [J].
Hermann, JS ;
Schoolfield, JD ;
Schenk, RK ;
Buser, D ;
Cochran, DL .
JOURNAL OF PERIODONTOLOGY, 2001, 72 (10) :1372-1383