Fixation with bioabsorbable pins in chevron bunionectomy

被引:40
作者
Gill, LH [1 ]
Martin, DF [1 ]
Coumas, JM [1 ]
Kiebzak, GM [1 ]
机构
[1] CAROLINAS MED CTR,CHARLOTTE,NC 28232
关键词
D O I
10.2106/00004623-199710000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fixation with bioabsorbable pins in distal chevron bunionectomy reduces the inconvenience and the risk of infection associated with fixation, with stainless-steel Kirschner wires, which leaves a portion of the wires protruding from the skin, However, use of bioabsorbable implants has been reported to be associated with osteolysis and formation of a sinus with a sterile discharge, We studied the outcome and complications seen with use of poly-p-dioxanone pins and those seen with use of stainless-steel Kirschner wires after chevron bunionectomy in 114 patients (144 feet). We found no difference between the treatment groups with regard to the prevalence of complications or the stability of fixation, Notably, the prevalence of osteolysis was quite similar between the treatment groups; none of the feet that had had fixation with bioabsorbable pins had formation of a sinus with a sterile discharge, We believe that bioabsorbable pins can be used reliably to fix the site of the osteotomy for a distal chevron bunionectomy, without undue risk of osteolysis or other complications.
引用
收藏
页码:1510 / 1518
页数:9
相关论文
共 38 条
[1]   BIODEGRADABLE FIXATION OF ANKLE FRACTURES - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY OF 32 CASES [J].
AHL, T ;
DALEN, N ;
LUNDBERG, A ;
WYKMAN, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :166-170
[2]  
Austin DW, 1981, CLIN ORTHOP RELAT R, V157, P25
[3]  
Barrows T., 1986, CLIN MATER, V1, P233, DOI [DOI 10.1016/S0267-6605(86)80015-4, 10.1016/S0267-6605(86)80015-4]
[4]  
BHATIA S, 1994, J BIOMAT SCI-POLYM E, V6, P435
[5]   FOREIGN-BODY REACTIONS TO POLYGLYCOLIDE SCREWS - OBSERVATIONS IN 24/216 MALLEOLAR FRACTURE CASES [J].
BOSTMAN, O ;
PARTIO, E ;
HIRVENSALO, E ;
ROKKANEN, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (02) :173-176
[6]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[7]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[8]   FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE [J].
BUCHOLZ, RW ;
HENRY, S ;
HENLEY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :319-324
[9]  
BUCHOLZ RW, 1996, ANN M AM AC ORTH SUR
[10]  
Corless J.R., 1976, J BONE JT SURG B, V58, P138