Full-scale tests on bending behavior of segmental joints for large underwater shield tunnels

被引:146
作者
Feng, Kun [1 ]
He, Chuan [1 ]
Qiu, Yue [1 ]
Zhang, Li [1 ]
Wang, Wei [1 ]
Xie, Hongming [1 ]
Zhang, Yanyang [1 ]
Cao, Songyu [1 ]
机构
[1] Southwest Jiaotong Univ, Minist Educ, Key Lab Transportat Tunnel Engn, Chengdu 610031, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Underwater shield tunnels; Segmental joints; Bending behavior; Full-scale tests; Failure characteristics;
D O I
10.1016/j.tust.2018.02.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental and numerical study on the bending behaviour of segmental joints for large underwater shield tunnels. A series of full-scale tests of segmental joint for underwater shield tunnel are carried out to investigate the bending performance under compression-bending loads. And comparative numerical simulations are conducted to compare with the test results and analyze the occurrence and development process of joint failure. The results indicate that the joint opens linearly and deforms nonlinearly after the visible concrete cracking occurred, the shape of joint interface is a curved surface during joint opening. The time when the bolt becomes stressed depended on axial force, and the bolt stress increased linearly with the growth of bending moment. Joint bending stiffness can be divided into three stages according to turning point of visible concrete cracking' and bolt yield', large axial force has a great influence on keeping it. The joint waterproof material could hardly promote the bending stiffness and capacity of segmental joint for its small rigidity. The failure process of segmental joint was different between under positive and negative bending moment, the compressive capacity of concrete in compression zone near the intrados played a vital role in the process of improving the bending capacity of segmental joint. The numerical results of joint opening and bending stiffness were in good agreement with tests during small deformation stage, while after visible cracking the results differ relatively. It is reasonable to simulate joint bending performance before visible concrete cracking, and estimated joint failure mode and its approximate range by using the proposed numerical model.
引用
收藏
页码:100 / 116
页数:17
相关论文
共 19 条
[1]  
Chen Z., 2010, Underground Engineering and Tunnels, V4, P17, DOI DOI 10.13547/J.CNKI.DXGCYSD.2010.04.011
[2]  
Hayashi M, 1997, THESIS
[3]  
Hirotomo M., 1978, P JAPAN SOC CIVIL EN, V272, P103, DOI DOI 10.2208/JSCEJ1969.1978.272_103
[4]  
Huang Z.H., 2003, UNDERGR SPACE, V23, P296
[5]  
Iftimie T, 1992, P ITA INT C NEW WORL, P321
[6]  
Jiang JJ, 2005, SENIOR CONCRETE STRU
[7]   Present status and technology of shield tunneling method in Japan [J].
Koyama, Y .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2003, 18 (2-3) :145-159
[8]   Experimental and analytical study on longitudinal joint opening of concrete segmental lining [J].
Li, Xiaojun ;
Yan, Zhiguo ;
Wang, Zhen ;
Zhu, Hehua .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2015, 46 :52-63
[9]  
Murakami H, 1980, J JSCE, P73
[10]   Effects of lateral unloading on the mechanical and deformation performance of shield tunnel segment joints [J].
Shi Chenghua ;
Cao Chengyong ;
Lei Mingfeng ;
Peng Limin ;
Ai Huijun .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2016, 51 :175-188