Experimental research on the ash deposition characteristics of 3-D finned tube bundle

被引:20
作者
Cheng, Min [1 ,2 ]
Chen, Zi-yong [1 ,2 ]
Liao, Qiang [1 ,2 ]
Zhang, Jun-nan [1 ,2 ]
Ding, Yu-dong [1 ,2 ]
Zhu, Xun [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Inst Engn Thermal Phys, Sch Energy & Power Engn, Chongqing 400030, Peoples R China
关键词
3-D finned tube bundle; Ash deposition characteristics; Transverse tube pitch; Longitudinal tube pitch; Fin height; HEAT-TRANSFER CHARACTERISTICS; FOULING CHARACTERISTICS; PARTICLE DEPOSITION; PRESSURE-DROP; EXCHANGERS; FLOW; SIMULATION; PARAMETER; MODEL;
D O I
10.1016/j.applthermaleng.2019.03.051
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ash deposition on the flue gas side of a heat recovery device can cause significant industrial problems. 3-D finned tube is a new type of heat exchanger element with potential anti-fouling property. However, the ash deposition characteristics of 3-D finned tube bundle are still unclear. In the current study, experiments were conducted to study the ash distribution characteristics of 3-D finned tube bundle with six-tube rows. The effects of the tube bundle structure, including the transverse tube pitch, longitudinal tube pitch and fin height, were investigated on the ash distribution around the tube along with the overall ash deposition weight. The results indicate that ash particles primarily distribute on the fin surface under different arrangements of the 3-D tube bundle. Larger particles prefer to settle on the tube surface of the top side and the leeward side, whereas smaller particles primarily settle on the fin surface of the windward side and the leeward side. The weight measurement results indicate that a longer transverse tube pitch and a shorter longitudinal tube pitch significantly restrict the ash deposition under current operating conditions. The ash deposition first decreases and then intensifies with an increase in fin height from 2 mm to 5 mm. The optimal fin height for anti-fouling is 3 mm.
引用
收藏
页码:556 / 564
页数:9
相关论文
共 27 条
[1]   Influence of the Apex Angle of Cone-Shaped Tubes on Particulate Fouling of Heat Exchangers [J].
Abd-Elhady, Mohamed S. ;
Rindt, Camilo C. M. ;
Van Steenhoven, Anton A. .
HEAT TRANSFER ENGINEERING, 2011, 32 (3-4) :272-281
[2]   Minimum gas speed in heat exchangers to avoid particulate fouling [J].
Abd-Elhady, MS ;
Rindt, CCM ;
Wijers, JG ;
van Steenhoven, AA ;
Bramer, EA ;
van der Meer, TH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (17-18) :3943-3955
[3]  
[Anonymous], NAT ENV POLLUT TECHN
[4]   A MECHANISTIC DESCRIPTION OF ASH DEPOSITION DURING PULVERIZED COAL COMBUSTION - PREDICTIONS COMPARED WITH OBSERVATIONS [J].
BAXTER, LL ;
DESOLLAR, RW .
FUEL, 1993, 72 (10) :1411-1418
[5]   Design of a novel, intensified heat exchanger for reduced fouling rates [J].
Bouris, D ;
Konstantinidis, E ;
Balabani, S ;
Castiglia, D ;
Bergeles, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (18) :3817-3832
[6]   Numerical evaluation of alternate tube configurations for particle deposition rate reduction in heat exchanger tube bundles [J].
Bouris, D ;
Papadakis, G ;
Bergeles, G .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2001, 22 (05) :525-536
[7]   Experimental investigation on the air-side flow and heat transfer characteristics of 3-D finned tube bundle [J].
Chen, Zi-yong ;
Cheng, Min ;
Liao, Qiang ;
Ding, Yu-dong ;
Zhang, Jun-nan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 131 :506-516
[8]   Numerical investigation on ash fouling characteristics of flue gas heat exchanger [J].
Fu, Lei ;
Liu, Pengfei ;
Li, Guojun .
APPLIED THERMAL ENGINEERING, 2017, 123 :891-900
[9]   A parameter study of tube bundle heat exchangers for fouling rate reduction [J].
Han, Hui ;
He, Ya-Ling ;
Tao, Wen-Quan ;
Li, Yin-Shi .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 72 :210-221
[10]  
[何雅玲 He Yaling], 2016, [科学通报, Chinese Science Bulletin], V61, P1858