Assessment of image quality in x-ray radiography imaging using a small plasma focus device

被引:6
|
作者
Kanani, A. [1 ]
Shirani, B. [1 ]
Jabbari, I. [1 ]
Mokhtari, J. [2 ]
机构
[1] Univ Isfahan, Fac Adv Sci & Technol, Esfahan, Iran
[2] Shiraz Univ, Dept Nucl Engn, Shiraz, Iran
关键词
Plasma focus; Radiography; Contrast; Line spread function; Modulation transfer function; Cut off frequency;
D O I
10.1016/j.radphyschem.2014.04.010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [41] Measurement of soft X-ray radiation using the PF-4 plasma focus setup with semiconductor X-ray detectors
    S. P. Eliseev
    V. Ya. Nikulin
    P. V. Silin
    Bulletin of the Lebedev Physics Institute, 2009, 36 : 1 - 7
  • [42] X-ray enhancement from a plasma focus by inserting lead at the anode tip
    Hussain, S
    Zakaullah, M
    Ali, S
    Bhatti, SH
    Waheed, A
    PHYSICS LETTERS A, 2003, 319 (1-2) : 181 - 187
  • [43] X-ray Intensity Measurements in 2.8 kJ Plasma Focus Device Operated with Argon Using a Five Channel Diode Spectrometer
    Sh. Al-Hawat
    M. Akel
    S. Shaaban
    Journal of Fusion Energy, 2015, 34 : 163 - 171
  • [44] X-ray Intensity Measurements in 2.8 kJ Plasma Focus Device Operated with Argon Using a Five Channel Diode Spectrometer
    Al-Hawat, Sh
    Akel, M.
    Shaaban, S.
    JOURNAL OF FUSION ENERGY, 2015, 34 (01) : 163 - 171
  • [45] Correlation between pinch dynamics, neutron and X-ray emission from megajoule plasma focus device
    Scholz, M
    Bienkowska, B
    Ivanova-Stanik, IM
    Karpinski, L
    Paduch, M
    Tomaszewski, K
    Zielinska, E
    Kravarik, J
    Kubes, P
    Banaszak, A
    Jakubowski, L
    Sadowski, M
    Szydlowski, A
    Schmid, H
    Vitulli, S
    VACUUM, 2004, 76 (2-3) : 361 - 364
  • [46] Experimental study of soft X-ray intensity with different anode tips in Amirkabir plasma focus device
    Habibi, Morteza
    Mahtab, Mahsa
    PRAMANA-JOURNAL OF PHYSICS, 2016, 87 (01):
  • [47] Nitrogen soft and hard X-ray emissions using different shapes of anodes in a 4-kJ plasma focus device
    M. Mahtab
    M. Habibi
    Plasma Physics Reports, 2013, 39 : 993 - 998
  • [48] Energy spectra measurements of X-ray emission from electron interaction in a dense plasma focus device
    Tartari, A
    Da Re, A
    Bonifazzi, C
    Marziani, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 206 - 209
  • [49] Experimental study of soft X-ray intensity with different anode tips in Amirkabir plasma focus device
    MORTEZA HABIBI
    MAHSA MAHTAB
    Pramana, 2016, 87
  • [50] Soft X-ray emission from preionized He plasma in a 3.3 kJ Mather type plasma focus device
    Khan, H. U.
    Shafiq, M.
    Hussain, S. S.
    Ahmad, S.
    Zakaullah, M.
    PLASMA DEVICES AND OPERATIONS, 2009, 17 (04): : 257 - 264