Assessment of image quality in x-ray radiography imaging using a small plasma focus device

被引:6
|
作者
Kanani, A. [1 ]
Shirani, B. [1 ]
Jabbari, I. [1 ]
Mokhtari, J. [2 ]
机构
[1] Univ Isfahan, Fac Adv Sci & Technol, Esfahan, Iran
[2] Shiraz Univ, Dept Nucl Engn, Shiraz, Iran
关键词
Plasma focus; Radiography; Contrast; Line spread function; Modulation transfer function; Cut off frequency;
D O I
10.1016/j.radphyschem.2014.04.010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [1] Preliminary study on X-ray source from Plasma Focus device for fast radiography
    Da Re, A
    Mezzetti, F
    Tartari, A
    Verri, G
    Rapezzi, L
    Gribkov, VA
    NUKLEONIKA, 2001, 46 : S123 - S125
  • [2] Low Energy Plasma Focus as an Intense X-ray Source for Radiography
    S.Hussain
    M.Zakaullah
    Shujaat Ali
    A.Waheed
    Plasma Science & Technology, 2004, (03) : 2296 - 2300
  • [3] Low energy plasma focus as an intense X-ray source for radiography
    Hussain, S
    Zakaullah, A
    Ali, S
    Waheed, A
    PLASMA SCIENCE & TECHNOLOGY, 2004, 6 (03) : 2296 - 2300
  • [4] Miniature Plasma Focus Device as a Compact Hard X-Ray Source for Fast Radiography Applications
    Verma, Rishi
    Rawat, R. S.
    Lee, Paul
    Krishnan, Mahadevan
    Springham, Stuart V.
    Tan, T. L.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (04) : 652 - 657
  • [5] Soft X-ray Imaging using a Neon Filled Plasma Focus X-ray Source
    R. S. Rawat
    T. Zhang
    G. J. Lim
    W. H. Tan
    S. J. Ng
    A. Patran
    S. M. Hassan
    S. V. Springham
    T. L. Tan
    M. Zakaullah
    P. Lee
    S. Lee
    Journal of Fusion Energy, 2004, 23 : 49 - 53
  • [6] Plasma Focus as a High Intensity Flash X-Ray Source for Biological Radiography
    S. Hussain
    S. Ahmad
    M. Z. Khan
    M. Zakaullah
    A. Waheed
    Journal of Fusion Energy, 2003, 22 : 195 - 200
  • [7] Soft X-ray imaging using a neon filled plasma focus X-ray source
    Rawat, RS
    Zhang, T
    Lim, GJ
    Tan, WH
    Ng, SJ
    Patran, A
    Hassan, SM
    Springham, SV
    Tan, TL
    Zakaullah, M
    Lee, P
    Lee, S
    JOURNAL OF FUSION ENERGY, 2004, 23 (01) : 49 - 53
  • [8] Plasma focus as a high intensity flash X-ray source for biological radiography
    Hussain, S
    Ahmad, S
    Khan, MZ
    Zakaullah, M
    Waheed, A
    JOURNAL OF FUSION ENERGY, 2003, 22 (03) : 195 - 200
  • [9] Small plasma focus studied as a source of hard X-ray
    Castillo-Mejía, F
    Milanese, MM
    Moroso, RL
    Pouzo, JO
    Santiago, MA
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2001, 29 (06) : 921 - 926
  • [10] Tailoring a plasma focus as hard x-ray source for imaging
    Hussain, S.
    Shafiq, M.
    Zakaullah, M.
    APPLIED PHYSICS LETTERS, 2010, 96 (03)