Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis

被引:109
|
作者
Schachl, K
Alemu, H
Kalcher, K
Jezkova, J
Svancara, I
Vytras, K
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] UNIV PARDUBICE,DEPT ANALYT CHEM,CZ-53210 PARDUBICE,CZECH REPUBLIC
关键词
manganese dioxide; hydrogen peroxide; flow injection analysis; amperometry; modified carbon paste electrode;
D O I
10.1039/a701723e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode bulk modified with MnO2 was investigated as an amperometric detector for hydrogen peroxide in flow injection analysis (FIA). With an operating potential of +0.46 V versus Ag/AgCl, H2O2 produces catalytic oxidation currents which can be exploited for quantitative determinations. Factors influencing the analytical performance of the electrode, such as paste composition and pH, were studied both for batch voltammetry and for FIA. For the flow system the influence of the injection volume and flow rate were examined. The amperometric signals are linearly proportional to H2O2 concentrations in the range 0.5-350 mg l(-1), showing a detection limit (three times the signal-to-noise ratio) of 45 mu g l(-1).
引用
收藏
页码:985 / 989
页数:5
相关论文
共 50 条
  • [41] Determination of hydrogen peroxide using a potassium hexacyanoferrate(III) modified titanium dioxide electrode
    Mishima, Y
    Motonaka, J
    Maruyama, K
    Ikeda, S
    ANALYTICA CHIMICA ACTA, 1998, 358 (03) : 291 - 296
  • [42] Amperometric flow injection determination of fructose in honey with a carbon paste sensor based on fructose dehydrogenase
    Parellada, J
    Dominguez, E
    Fernandez, VM
    ANALYTICA CHIMICA ACTA, 1996, 330 (01) : 71 - 77
  • [43] Novel amperometric flow-injection analysis of creatinine using a molecularly-imprinted polymer coated copper oxide nanoparticle-modified carbon-paste-electrode
    Nontawong, Nongyao
    Amatatongchai, Maliwan
    Thimoonnee, Suphatsorn
    Laosing, Saowanee
    Jarujamrus, Purim
    Karuwan, Chanpen
    Chairam, Sanoe
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 175
  • [44] Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol
    Felix, Fabiana S.
    Brett, Christopher M. A.
    Angnes, Lucio
    TALANTA, 2008, 76 (01) : 128 - 133
  • [45] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [46] Flow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrode
    De Oliveira, MF
    Saczk, AA
    Neto, JAG
    Roldan, PS
    Stradiotto, NR
    SENSORS, 2003, 3 (09): : 371 - 380
  • [47] Nonenzymatic amperometric determination of hydrogen peroxide by graphene and gold nanorods nanocomposite modified electrode
    Pang, Pengfei
    Yang, Zhongming
    Xiao, Shixiu
    Xie, Jinling
    Zhang, Yanli
    Gao, Yuntao
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 727 : 27 - 33
  • [48] Determination of hydrogen peroxide and ampicillin using a flow injection analysis method with chemiluminescence detection
    Chivulescu, AI
    Danet, AF
    Kalinowski, S
    REVISTA DE CHIMIE, 2005, 56 (07): : 695 - 698
  • [49] Flow injection analysis of aziprotryne using an electrochemical sensor based on cobalt phthalocyanine modified carbon paste electrode
    Chicharro, M
    Zapardiel, A
    Bermejo, E
    Madrid, E
    Rodríguez, C
    ELECTROANALYSIS, 2002, 14 (13) : 892 - 898
  • [50] Fabrication of gallium hexacyanoferrate modified carbon ionic liquid paste electrode for sensitive determination of hydrogen peroxide and glucose
    Haghighi, Behzad
    Khosravi, Mehdi
    Barati, Ali
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 40 : 204 - 211