Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis

被引:109
|
作者
Schachl, K
Alemu, H
Kalcher, K
Jezkova, J
Svancara, I
Vytras, K
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] UNIV PARDUBICE,DEPT ANALYT CHEM,CZ-53210 PARDUBICE,CZECH REPUBLIC
关键词
manganese dioxide; hydrogen peroxide; flow injection analysis; amperometry; modified carbon paste electrode;
D O I
10.1039/a701723e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode bulk modified with MnO2 was investigated as an amperometric detector for hydrogen peroxide in flow injection analysis (FIA). With an operating potential of +0.46 V versus Ag/AgCl, H2O2 produces catalytic oxidation currents which can be exploited for quantitative determinations. Factors influencing the analytical performance of the electrode, such as paste composition and pH, were studied both for batch voltammetry and for FIA. For the flow system the influence of the injection volume and flow rate were examined. The amperometric signals are linearly proportional to H2O2 concentrations in the range 0.5-350 mg l(-1), showing a detection limit (three times the signal-to-noise ratio) of 45 mu g l(-1).
引用
收藏
页码:985 / 989
页数:5
相关论文
共 50 条
  • [31] A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode
    Kulizic, Mihajlo
    Stankovic, Milan
    Rasic, Marija
    Mijatovic, Aleksandar
    Baosic, Rada
    Lolic, Aleksandar
    CHEMISTRYSELECT, 2023, 8 (48):
  • [32] Flow-injection electrochemical determination of citric acid using a cobalt(II)-phthalocyanine modified carbon paste electrode
    do Nascimento, Raphael Fonseca
    Guimaraes Selva, Thiago Matheus
    Ribeiro, Williame Farias
    Belian, Monica Freire
    Angnes, Lucio
    do Nascimento, Valberes Bernardo
    TALANTA, 2013, 105 : 354 - 359
  • [33] Sensitive Flow-Injection Electrochemical Determination of Hydrogen Peroxide at a Palladium Nanoparticle-Modified Pencil Graphite Electrode
    Karakaya, Serkan
    Dilgin, Yusuf
    ANALYTICAL LETTERS, 2019, 52 (06) : 998 - 1017
  • [34] Determination of hydrogen peroxide, glucose and hypoxanthine using (bio) sensors based on ruthenium dioxide-modified screen-printed electrodes
    Kotzian, P
    Brázdilová, P
    Kalcher, K
    Vytras, K
    ANALYTICAL LETTERS, 2005, 38 (07) : 1099 - 1113
  • [35] CARBON-PASTE ELECTRODE INCORPORATED WITH COBALT(II) OCTAETHOXYPHTHALOCYANINE FOR THE AMPEROMETRIC DETECTION OF HYDROGEN-PEROXIDE
    MIZUTANI, F
    YABUKI, S
    IIJIMA, S
    ELECTROANALYSIS, 1995, 7 (08) : 706 - 709
  • [36] Amperometric Determination of Hydrogen Peroxide in Whitening Gels Using Boron-doped Diamond Electrode
    Azevedo, Gustavo C.
    Castro, Roberto H. S.
    Matos, Maria Auxiliadora C.
    Matos, Renato Camargo
    ANALYTICAL SCIENCES, 2018, 34 (08) : 913 - 917
  • [37] Electrocatalytic amperometric determination of amitrole using a cobalt-phthalocyanine-modified carbon paste electrode
    Chicharro, M
    Zapardiel, A
    Bermejo, E
    Moreno, M
    Madrid, E
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (4-5) : 277 - 283
  • [38] Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles
    Amatatongchai, Maliwan
    Sroysee, Wongduan
    Chairam, Sanoe
    Nacapricha, Duangjai
    TALANTA, 2015, 133 : 134 - 141
  • [39] Poly(Celestine Blue)-Graphene Oxide Nanohybrid Modified Electrode for Amperometric Determination of Hydrogen Peroxide
    Sangeetha, N. S.
    Ramaprabhu, Sundara
    Narayanan, S. Sriman
    GRAPHENE, 2013, 1 (02) : 136 - 141
  • [40] An Efficient Sensor for Determination of Concentrated Hydrogen Peroxide Based on Nickel Oxide Modified Carbon Paste Electrode
    Ojani, Reza
    Raoof, Jahan-Bakhsh
    Norouzi, Banafsheh
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 1852 - 1863