Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis

被引:109
|
作者
Schachl, K
Alemu, H
Kalcher, K
Jezkova, J
Svancara, I
Vytras, K
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] UNIV PARDUBICE,DEPT ANALYT CHEM,CZ-53210 PARDUBICE,CZECH REPUBLIC
关键词
manganese dioxide; hydrogen peroxide; flow injection analysis; amperometry; modified carbon paste electrode;
D O I
10.1039/a701723e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode bulk modified with MnO2 was investigated as an amperometric detector for hydrogen peroxide in flow injection analysis (FIA). With an operating potential of +0.46 V versus Ag/AgCl, H2O2 produces catalytic oxidation currents which can be exploited for quantitative determinations. Factors influencing the analytical performance of the electrode, such as paste composition and pH, were studied both for batch voltammetry and for FIA. For the flow system the influence of the injection volume and flow rate were examined. The amperometric signals are linearly proportional to H2O2 concentrations in the range 0.5-350 mg l(-1), showing a detection limit (three times the signal-to-noise ratio) of 45 mu g l(-1).
引用
收藏
页码:985 / 989
页数:5
相关论文
共 50 条
  • [21] Potentiometric determination of hydrogen peroxide at MnO2-doped carbon paste electrode
    Zheng, XW
    Guo, ZH
    TALANTA, 2000, 50 (06) : 1157 - 1162
  • [22] Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode
    Chuan-Liang Hsu
    Hung-Der Jang
    Ming-Sheng Su
    Ku-Shang Chang
    Yung-Sheng Huang
    European Food Research and Technology, 2008, 226 : 809 - 815
  • [23] Chemiluminescent determination of luminol and hydrogen peroxide using hematin immobilized in the bulk of a carbon paste electrode
    Xu, GB
    Dong, SJ
    ELECTROANALYSIS, 1999, 11 (16) : 1180 - 1184
  • [24] Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode
    Hsu, Chuan-Liang
    Jang, Hung-Der
    Su, Ming-Sheng
    Chang, Ku-Shang
    Huang, Yung-Sheng
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2008, 226 (04) : 809 - 815
  • [25] ELECTROCATALYSIS AND FLOW-INJECTION ANALYSIS OF HYDROGEN-PEROXIDE AT A CHEMICALLY MODIFIED ELECTRODE
    GAO, ZQ
    IVASKA, A
    LI, P
    LUI, KZ
    YANG, JJ
    ANALYTICA CHIMICA ACTA, 1992, 259 (02) : 211 - 218
  • [26] A Prussian blue-carbon paste electrode for selective cathodic amperometric determination of nitrite using a flow-injection analysis system with carrier recycling
    Pradela-Filho, Lauro A.
    Oliveira, Brandon C.
    Takeuchi, Regina M.
    Santos, Andre L.
    ELECTROCHIMICA ACTA, 2015, 180 : 939 - 946
  • [27] AMPEROMETRIC DETERMINATION OF DOPAMINE ON AN ENZYMATICALLY MODIFIED CARBON-PASTE ELECTRODE
    FORZANI, ES
    RIVAS, GA
    SOLIS, VM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 382 (1-2): : 33 - 40
  • [28] Phosphomolybdate-polypyrrole composite bulk-modified carbon paste electrode for a hydrogen peroxide amperometric sensor
    Wang, XL
    Zhang, H
    Wang, EB
    Han, ZB
    Hu, CW
    MATERIALS LETTERS, 2004, 58 (10) : 1661 - 1664
  • [29] Modified carbon paste electrodes for flow injection amperometric determination of isocitrate dehydrogenase activity in serum
    Rodríguez-Granda, P
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    ANALYTICAL BIOCHEMISTRY, 2002, 308 (02) : 195 - 203
  • [30] Cost-effective flow injection amperometric system with metal nanoparticle loaded carbon nanotube modified screen printed carbon electrode for sensitive determination of hydrogen peroxide
    Reanpang, Preeyaporn
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Chailapakul, Orawon
    Jakmunee, Jaroon
    TALANTA, 2015, 144 : 868 - 874