Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis

被引:110
作者
Schachl, K
Alemu, H
Kalcher, K
Jezkova, J
Svancara, I
Vytras, K
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] UNIV PARDUBICE,DEPT ANALYT CHEM,CZ-53210 PARDUBICE,CZECH REPUBLIC
关键词
manganese dioxide; hydrogen peroxide; flow injection analysis; amperometry; modified carbon paste electrode;
D O I
10.1039/a701723e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode bulk modified with MnO2 was investigated as an amperometric detector for hydrogen peroxide in flow injection analysis (FIA). With an operating potential of +0.46 V versus Ag/AgCl, H2O2 produces catalytic oxidation currents which can be exploited for quantitative determinations. Factors influencing the analytical performance of the electrode, such as paste composition and pH, were studied both for batch voltammetry and for FIA. For the flow system the influence of the injection volume and flow rate were examined. The amperometric signals are linearly proportional to H2O2 concentrations in the range 0.5-350 mg l(-1), showing a detection limit (three times the signal-to-noise ratio) of 45 mu g l(-1).
引用
收藏
页码:985 / 989
页数:5
相关论文
共 35 条
[1]   VOLTAMMETRIC BEHAVIOR OF PERBORATE ON PRUSSIAN-BLUE-MODIFIED CARBON PASTE ELECTRODES [J].
BOYER, A ;
KALCHER, K ;
PIETSCH, R .
ELECTROANALYSIS, 1990, 2 (02) :155-161
[2]   ELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE ON A PALLADIUM-MODIFIED CARBON-PASTE ELECTRODE [J].
CAI, XH ;
KALCHER, K ;
KOLBL, G ;
NEUHOLD, C ;
DIEWALD, W ;
OGOREVC, B .
ELECTROANALYSIS, 1995, 7 (04) :340-345
[3]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[4]   VOLTAMMETRIC REDUCTION AND DETERMINATION OF HYDROGEN-PEROXIDE AT AN ELECTRODE MODIFIED WITH A FILM CONTAINING PALLADIUM AND IRIDIUM [J].
COX, JA ;
JAWORSKI, RK .
ANALYTICAL CHEMISTRY, 1989, 61 (19) :2176-2178
[5]   CHARACTERIZATION OF ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC ;
STRASSER, VA .
ANALYTICAL CHEMISTRY, 1984, 56 (02) :136-141
[6]   ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2310-2314
[7]  
FARSANG G, 1967, ACTA CHIM HUNG, V52, P123
[8]   ELECTROCATALYSIS AND FLOW-INJECTION ANALYSIS OF HYDROGEN-PEROXIDE AT A CHEMICALLY MODIFIED ELECTRODE [J].
GAO, ZQ ;
IVASKA, A ;
LI, P ;
LUI, KZ ;
YANG, JJ .
ANALYTICA CHIMICA ACTA, 1992, 259 (02) :211-218
[9]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[10]   AN INVESTIGATION OF THE INFLUENCES OF THE BACKGROUND MATERIAL AND LAYER THICKNESS OF SPUTTERED PALLADIUM GOLD ON CARBON ELECTRODES FOR THE AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE [J].
GORTON, L ;
SVENSSON, T .
JOURNAL OF MOLECULAR CATALYSIS, 1986, 38 (1-2) :49-60