Investigation on the role of mass flow rate in UTSG reverse flow under natural circulation condition

被引:5
作者
Xu, Zhigang [1 ]
Ji, Huaran [2 ]
Hong, Gang [3 ]
Bian, Boshen [3 ]
Huang, Yanping [4 ]
Xu, Jianjun [4 ]
机构
[1] Tianjin Univ, State Key Lab Engines, Tianjin, Peoples R China
[2] Xiamen Univ, Dept Biomat, Biomed Engn Res Ctr, Coll Mat, Xiamen, Fujian, Peoples R China
[3] Xiamen Univ, Coll Energy, Xiamen, Fujian, Peoples R China
[4] CNNC Key Lab Nucl Reactor Thermal Hydraul Technol, Chengdu, Sichuan, Peoples R China
关键词
UTSG; Reverse flow; CFD; Natural circulation; PRIMARY SIDE; U-TUBES;
D O I
10.1016/j.anucene.2019.07.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In view of the phenomenon of reverse flow in partial inverted U-tubes of inverted U-tube steam generator (UTSG) under natural circulation condition, the numerical calculation method is used to study the flow and heat transfer in the primary side of UTSG. There are many factors influencing reverse flow in UTSG, such as the inverted U-tube length, coolant mass flow, operating pressure and temperature difference between primary and secondary side. However, in a specific UTSG, the lengths of different inverted U-tubes and the variations of internal mass flow rates are not uniform, so it is difficult to study the reverse flow mechanism. In this paper, we study the reverse flow of UTSG with identical tubes. Results show that under natural circulation condition, it is more favorable to reduce reverse flow as total inlet mass flow rate in UTSG increases. In addition, the critical value of reversion is calculated, which provides a reference for the engineering design and reactor safety analysis of UTSG. The spatial distribution of the reverse tubes is related to the inlet initial mass flow rate of U-tube and the U-tube with small inlet initial mass flow rate is more likely to happen reverse flow. U-tube with least inlet mass flow rate firstly triggers to the inflexion point of reversion, and the second least one happens reverse flow next while the total inlet mass flow rate in UTSG decreases gradually. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:763 / 772
页数:10
相关论文
共 12 条
[1]   Numerical study on flow inversion in UTSG under natural circulation [J].
Bian, Bo-shen ;
Hong, Gang ;
Li, Ning ;
Xu, Zhi-gang ;
Huang, Yan-ping ;
Xu, Jian-jun ;
Tang, Yu .
ANNALS OF NUCLEAR ENERGY, 2018, 115 :315-322
[2]   Effect of U-tube length on reverse flow in UTSG primary side under natural circulation [J].
Hao, Jianli ;
Chen, Wenzhen ;
Zhang, De .
ANNALS OF NUCLEAR ENERGY, 2013, 56 :66-70
[3]   Experimental and numerical investigations on the reverse flow phenomena in UTSGs [J].
Hu, Gaojie ;
Yu, Lei ;
Chen, Wenzhen ;
Hao, Jianli ;
Chu, Xi .
PROGRESS IN NUCLEAR ENERGY, 2016, 92 :147-154
[4]  
IAEA, 2005, IAEA-TECDOC-1474
[5]   Non-uniform flow distribution in the steam generator U-tubes of a pressurized water reactor plant during singleand two-phase natural circulations [J].
Jeong, JJ ;
Hwang, M ;
Lee, YJ ;
Chung, BD .
NUCLEAR ENGINEERING AND DESIGN, 2004, 231 (03) :303-314
[6]   Single-phase flow excursion in the primary side of a vertical, inverted u-tube steam generator [J].
Jeong, JJ ;
Hwang, M ;
Lee, YJ .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2003, 30 (05) :643-652
[7]   NONUNIFORM STEAM-GENERATOR U-TUBE FLOW DISTRIBUTION DURING NATURAL CIRCULATION TESTS IN ROSA-IV LARGE-SCALE TEST FACILITY [J].
KUKITA, Y ;
NAKAMURA, H ;
TASAKA, K ;
CHAULIAC, C .
NUCLEAR SCIENCE AND ENGINEERING, 1988, 99 (04) :289-298
[8]   STABILITY OF SINGLE-PHASE NATURAL CIRCULATION WITH INVERTED U-TUBE STEAM-GENERATORS [J].
SANDERS, J .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1988, 110 (03) :735-742
[9]  
[王川 Wang Chuan], 2011, [核动力工程, Nuclear Power Engineering], V32, P58
[10]   System-CFD coupled simulations of flow instability in steam generator U tubes [J].
Watanabe, Tadashi ;
Anoda, Yoshinari ;
Takano, Masahito .
ANNALS OF NUCLEAR ENERGY, 2014, 70 :141-146