Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer

被引:1
作者
Adeneye, Samuel [1 ]
Akpochafor, Michael [1 ]
Habeebu, Muhammad [1 ]
Omojola, Akintayo [3 ]
Joseph, Adedayo [2 ]
Awhariado, John [1 ]
Durosinnmi-Etti, Abayomi [2 ]
Aweda, Moses [1 ]
机构
[1] Univ Lagos, Coll Med, Dept Radiat Biol Radiotherapy & Radiodiag, Lagos, Nigeria
[2] Lagos Univ, Dept Radiotherapy, Nigerian Sovereign Investment Author, Teaching Hosp, Lagos, Nigeria
[3] Fed Med Ctr Asaba, Med Phys Unit, Dept Radiol, Asaba, Nigeria
来源
TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY | 2021年 / 36卷 / 01期
关键词
Conformity index; homogeneity index; intensity modulated radiotherapy; prostate cancer; 3D-conformal radiotherapy; RADIATION; IMRT; ARC;
D O I
10.5505/tjo.2020.2437
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE We evaluated the homogeneity index and conformity index using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) treatment plans in prostate cancer. METHODS Twenty treatment plans for ten patients were created using 3D-CRT of four-fields with gantry angles of 0 degrees, 90 degrees, 180 degrees, and 270 degrees; and IMRT of five-fields with gantry angles of 0 degrees, 72 degrees, 144 degrees, 216 degrees, and 288 degrees on an Eclipse Treatment Planning System (version 15.6). The volume of reference isodose, target volume, maximum isodose in the target, reference isodose, dose at 95% of planning target volume (PTV), dose at 2%, 5%, and 98% of PTV, and prescribed dose were collected from the dose volume histogram of each plan. The conformity index and homogeneity index (HI) were then calculated. The doses of the organs at risk were also collected and evaluated. RESULTS The HI of the twenty patients who underwent the treatment plan with 3D-CRT was 1.088 +/- 0.03, which shows good homogeneity, but less homogeneity when compared with plans done with IMRT (1.072 +/- 0.02). CONCLUSION The use of IMRT treatment plan for prostate cancer proved to be superior over 3D-CRT in terms of conformity and homogeneity, as well as sparring dose to organ at risk.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 50 条
  • [41] Intensity-modulated radiotherapy versus conventional three-dimensional conformal radiotherapy for boost or salvage treatment of nasopharyngeal carcinoma
    Hsiung, CY
    Yorke, ED
    Chui, CS
    Hunt, MA
    Ling, CC
    Huang, EY
    Wang, CJ
    Chen, HC
    Yeh, SA
    Hsu, HC
    Amols, HI
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (03): : 638 - 647
  • [42] Three-dimensional conformal radiotherapy, static intensity-modulated and helical intensity-modulated radiotherapy in glioblastoma. Dosimetric comparison in patients with overlap between target volumes and organs at risk
    Buglione, Michela
    Spiazzi, Luigi
    Saiani, Federica
    Costa, Loredana
    Shehi, Blerina
    Lazzari, Barbara
    Uccelli, Chiara
    Pasinetti, Nadia
    Borghetti, Paolo
    Triggiani, Luca
    Donadoni, Laura
    Pedretti, Sara
    Magrini, Stefano M.
    TUMORI, 2014, 100 (03) : 272 - 277
  • [43] Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer
    Martinez, AA
    Yan, D
    Lockman, D
    Brabbins, D
    Kota, K
    Sharpe, M
    Jaffray, DA
    Vicini, F
    Wong, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05): : 1226 - 1234
  • [44] Postoperative radiotherapy for prostate cancer - Evaluation of target motion and treatment techniques (intensity-modulated versus conformal radiotherapy)
    Pinkawa, Michael
    Siluschek, Jaroslav
    Gagel, Bernd
    Piroth, Marc D.
    Demirel, Cengiz
    Asadpour, Branka
    Eble, Michael J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 (01) : 23 - 29
  • [45] Adjuvant external beam radiotherapy after therapeutic groin lymphadenectomy for patients with melanoma: a dosimetric comparison of three-dimensional conformal and intensity-modulated radiotherapy techniques
    Adams, Gerard
    Foote, Matthew
    Brown, Simon
    Burmeister, Bryan
    MELANOMA RESEARCH, 2017, 27 (01) : 50 - 56
  • [46] Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using novalis system
    Ding, Meisong
    Newman, Francis
    Kavanagh, Brian D.
    Stuhr, Kelly
    Johnson, Tim K.
    Gaspar, Laurie E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04): : S82 - S86
  • [47] Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)
    Wang, Xin
    Li, Guangjun
    Zhang, Yingjie
    Bai, Sen
    Xu, Feng
    Wei, Yuquan
    Gong, Youling
    MEDICAL DOSIMETRY, 2013, 38 (04) : 395 - 400
  • [48] A comparative analysis of quality of life after postoperative intensity-modulated radiotherapy or three-dimensional conformal radiotherapy for cervical cancer
    Mohanty, Sarthak Kumar
    Chopra, Supriya
    Mudaliar, Anisha
    Kannan, Sadhana
    Mahantshetty, Umesh
    Engineer, Reena
    Ghosh, Jaya
    Bajpai, Jyoti
    Gupta, Sudeep
    Shrivastava, Shyamkishore
    INDIAN JOURNAL OF CANCER, 2018, 55 (04) : 327 - 335
  • [49] Dosimetric comparison between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in the treatment of different stages of nasopharyngeal carcinoma
    Ibrahim, Mohamed S.
    Attalla, Ehab M.
    El Naggar, Mostafa
    Elshemey, Wael M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 46 - 51
  • [50] An evaluation of three-field coplanar plans for conformal radiotherapy of prostate cancer
    Khoo, VS
    Bedford, JL
    Webb, S
    Dearnaley, DP
    RADIOTHERAPY AND ONCOLOGY, 2000, 55 (01) : 31 - 40