Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer

被引:1
作者
Adeneye, Samuel [1 ]
Akpochafor, Michael [1 ]
Habeebu, Muhammad [1 ]
Omojola, Akintayo [3 ]
Joseph, Adedayo [2 ]
Awhariado, John [1 ]
Durosinnmi-Etti, Abayomi [2 ]
Aweda, Moses [1 ]
机构
[1] Univ Lagos, Coll Med, Dept Radiat Biol Radiotherapy & Radiodiag, Lagos, Nigeria
[2] Lagos Univ, Dept Radiotherapy, Nigerian Sovereign Investment Author, Teaching Hosp, Lagos, Nigeria
[3] Fed Med Ctr Asaba, Med Phys Unit, Dept Radiol, Asaba, Nigeria
来源
TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY | 2021年 / 36卷 / 01期
关键词
Conformity index; homogeneity index; intensity modulated radiotherapy; prostate cancer; 3D-conformal radiotherapy; RADIATION; IMRT; ARC;
D O I
10.5505/tjo.2020.2437
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE We evaluated the homogeneity index and conformity index using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) treatment plans in prostate cancer. METHODS Twenty treatment plans for ten patients were created using 3D-CRT of four-fields with gantry angles of 0 degrees, 90 degrees, 180 degrees, and 270 degrees; and IMRT of five-fields with gantry angles of 0 degrees, 72 degrees, 144 degrees, 216 degrees, and 288 degrees on an Eclipse Treatment Planning System (version 15.6). The volume of reference isodose, target volume, maximum isodose in the target, reference isodose, dose at 95% of planning target volume (PTV), dose at 2%, 5%, and 98% of PTV, and prescribed dose were collected from the dose volume histogram of each plan. The conformity index and homogeneity index (HI) were then calculated. The doses of the organs at risk were also collected and evaluated. RESULTS The HI of the twenty patients who underwent the treatment plan with 3D-CRT was 1.088 +/- 0.03, which shows good homogeneity, but less homogeneity when compared with plans done with IMRT (1.072 +/- 0.02). CONCLUSION The use of IMRT treatment plan for prostate cancer proved to be superior over 3D-CRT in terms of conformity and homogeneity, as well as sparring dose to organ at risk.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 50 条
  • [31] Comparative dosimetric evaluation of three-dimensional conformal and stereotactic radiotherapy for treatment of intracranial tumors
    Gupta, Manoj
    Babaiah, M.
    Kumar, M. Dinesh
    Hirapara, Pushpendra H.
    Patidar, Arvind K.
    Walke, Rahul V.
    JOURNAL OF THE EGYPTIAN NATIONAL CANCER INSTITUTE, 2012, 24 (04) : 169 - 173
  • [32] A Radiotherapy Planning Study of RapidArc, Intensity Modulated Radiotherapy, Three-Dimensional Conformal Radiotherapy, and Parallel Opposed Beams in the Treatment of Pediatric Retroperitoneal Tumors
    Shaffer, Richard
    Vollans, Emily
    Vellani, Rosie
    Welsh, Margaret
    Moiseenko, Vitali
    Goddard, Karen
    PEDIATRIC BLOOD & CANCER, 2011, 56 (01) : 16 - 23
  • [33] Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules
    Yadav, Poonam
    Yan, Yue
    Ignatowski, Tasha
    Olson, Anna
    MEDICAL DOSIMETRY, 2017, 42 (01) : 42 - 46
  • [34] Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: A dosimetric comparison
    Kinhikar, Rajesh A.
    Pawar, Amol B.
    Mahantshetty, Umesh
    Murthy, Vedang
    Dheshpande, Deepak D.
    Shrivastava, Shyam K.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2014, 10 (03) : 575 - 582
  • [35] Integral Dose in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Xie, C.
    Wang, J.
    CLINICAL ONCOLOGY, 2009, 21 (09) : 706 - 712
  • [36] Intensity-Modulated Radiotherapy Causes Fewer Side Effects than Three-Dimensional Conformal Radiotherapy When Used in Combination With Brachytherapy for the Treatment of Prostate Cancer
    Forsythe, Kevin
    Blacksburg, Seth
    Stone, Nelson
    Stock, Richard G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : 630 - 635
  • [37] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy, Dynamic Intensity Modulated Radiation Therapy, and Hybrid Planning for Treatment of Locally Advanced Lung Cancer
    Basaran, Hamit
    Inan, Gokcen
    Gul, Osman Vefa
    Duzova, Mursel
    MIDDLE EAST JOURNAL OF CANCER, 2022, 13 (03) : 523 - 530
  • [38] Dosimetric comparison of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for left-sided chest wall and lymphatic irradiation
    Kivanc, Huseyin
    Gultekin, Melis
    Gurkaynak, Murat
    Ozyigit, Gokhan
    Yildiz, Ferah
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (12): : 36 - 44
  • [39] Dosimetric comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy in patients with gynecologic malignancies: a systematic review and meta-analysis
    Baojuan Yang
    Lin Zhu
    Haiyan Cheng
    Qi Li
    Yunyan Zhang
    Yashuang Zhao
    Radiation Oncology, 7
  • [40] Dosimetric and clinical toxicity comparison of critical organ preservation with three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and RapidArc for the treatment of locally advanced cancer of the pancreatic head
    Jin, L.
    Wang, R.
    Jiang, S.
    Yue, J.
    Liu, T.
    Dou, X.
    Zhu, K.
    Feng, R.
    Xu, X.
    Chen, D.
    Yin, Y.
    CURRENT ONCOLOGY, 2016, 23 (01) : E41 - E48