Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer

被引:1
作者
Adeneye, Samuel [1 ]
Akpochafor, Michael [1 ]
Habeebu, Muhammad [1 ]
Omojola, Akintayo [3 ]
Joseph, Adedayo [2 ]
Awhariado, John [1 ]
Durosinnmi-Etti, Abayomi [2 ]
Aweda, Moses [1 ]
机构
[1] Univ Lagos, Coll Med, Dept Radiat Biol Radiotherapy & Radiodiag, Lagos, Nigeria
[2] Lagos Univ, Dept Radiotherapy, Nigerian Sovereign Investment Author, Teaching Hosp, Lagos, Nigeria
[3] Fed Med Ctr Asaba, Med Phys Unit, Dept Radiol, Asaba, Nigeria
来源
TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY | 2021年 / 36卷 / 01期
关键词
Conformity index; homogeneity index; intensity modulated radiotherapy; prostate cancer; 3D-conformal radiotherapy; RADIATION; IMRT; ARC;
D O I
10.5505/tjo.2020.2437
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE We evaluated the homogeneity index and conformity index using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) treatment plans in prostate cancer. METHODS Twenty treatment plans for ten patients were created using 3D-CRT of four-fields with gantry angles of 0 degrees, 90 degrees, 180 degrees, and 270 degrees; and IMRT of five-fields with gantry angles of 0 degrees, 72 degrees, 144 degrees, 216 degrees, and 288 degrees on an Eclipse Treatment Planning System (version 15.6). The volume of reference isodose, target volume, maximum isodose in the target, reference isodose, dose at 95% of planning target volume (PTV), dose at 2%, 5%, and 98% of PTV, and prescribed dose were collected from the dose volume histogram of each plan. The conformity index and homogeneity index (HI) were then calculated. The doses of the organs at risk were also collected and evaluated. RESULTS The HI of the twenty patients who underwent the treatment plan with 3D-CRT was 1.088 +/- 0.03, which shows good homogeneity, but less homogeneity when compared with plans done with IMRT (1.072 +/- 0.02). CONCLUSION The use of IMRT treatment plan for prostate cancer proved to be superior over 3D-CRT in terms of conformity and homogeneity, as well as sparring dose to organ at risk.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 50 条
  • [1] A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana
    Kyei, Kofi Adesi
    Daniels, Joseph
    Adom, Ameyaw Kwame
    Odonkor, Philip
    Nyantakyi, Andrew Yaw
    Adjabu, Dorothy Ekua
    ECANCERMEDICALSCIENCE, 2024, 18
  • [2] Dosimetric effect of Elekta Beam Modulator micromultileaf in three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer
    Carosi, Alessandra
    Ingrosso, Gianluca
    Ponti, Elisabetta
    Tolu, Barbara
    Murgia, Alessandra
    di Cristino, Daniela
    Santoni, Riccardo
    MEDICAL DOSIMETRY, 2014, 39 (02) : 180 - 184
  • [3] Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment
    Uysal, Bora
    Beyzadeoglu, Murat
    Sager, Omer
    Dincoglan, Ferrat
    Demiral, Selcuk
    Gamsiz, Hakan
    Surenkok, Serdar
    Oysul, Kaan
    BALKAN MEDICAL JOURNAL, 2013, 30 (01) : 54 - 57
  • [4] Dosimetric analysis of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy-step and shoot, helical tomotherapy, and volumetric modulated arc therapy in prostate cancer radiotherapy
    Gozal, Fenny
    Gondhowiardjo, Soehartati Argadikoesoema
    Kodrat, Henry
    Wibowo, Wahyu Edy
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) : 893 - 900
  • [5] VOLUMETRIC MODULATED ARC THERAPY FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Palma, David
    Vollans, Emily
    James, Kerry
    Nakano, Sandy
    Moiseenko, Vitali
    Shaffer, Richard
    Mckenzie, Michael
    Morris, James
    Otto, Karl
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 996 - 1001
  • [6] Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
    Liu, Yi-Chi
    Chang, Hung-Ming
    Lin, Hsin-Hon
    Lu, Chia-Chun
    Lai, Lu-Han
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 14
  • [7] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [8] Implementation of intensity-modulated radiotherapy and comparison with three-dimensional conformal radiotherapy in the postoperative treatment of cervical cancer
    Marjanovic, Dragoslava
    Plesinac-Karapandzic, Vesna
    Rundic, Suzana Stojanovic
    Tomasevic, Aleksandar
    Saric, Milan
    Miskovic, Ivana
    Nidzovic, Borko
    Mikovic, Mirjana
    Petrasinovic, Predrag
    JOURNAL OF BUON, 2019, 24 (05): : 2028 - 2034
  • [9] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [10] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy with Hybrid Intensity-Modulated Radiotherapy Techniques for Treatment of Locally Advanced Lung Cancer
    Suyunmez, Ozge
    Genc, Mine
    Ciftlikli, Ozlem Toykan
    Tuncel, Nina
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (03): : 239 - 245